Diagnostic accuracy of two cone-beam computed tomography systems for detection of strip perforation in the mesial root of mandibular molars

被引:1
作者
Maserat, Vida [1 ]
Ebrahimi, Heshmatallah Shahraki [2 ]
Saberi, Eshagh Ali [3 ]
Pirhaji, Arezoo [2 ]
Khosravii, Niloofar [4 ]
机构
[1] Zahedan Univ Med Sci, Dept Oral & Maxillofacial Radiol, Fac Dent, Zahedan, Iran
[2] Zahedan Univ Med Sci, Dept Endodont, Fac Dent, Zahedan, Iran
[3] Zahedan Univ Med Sci, Dept Endodont, Oral & Dent Dis Res Ctr, Fac Dent, Zahedan, Iran
[4] Birjand Univ Med Sci, Birjand, Southern Khoras, Iran
关键词
Cone Beam Computer Tomography; Three Dimensional Imaging; Accuracy; TEETH;
D O I
10.32067/GIE.2020.34.01.01
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: This study aimed to compare the diagnostic accuracy of two cone-beam computed tomography (CBCT) systems for detection of strip perforation in the mesiobuccal canal of mandibular molars after root canal treatment. Methodology: The curved mesiobuccal canals of mandibular first and second molars were instrumented as part of endodontic treatment. The canals were strip-perforated using #2 and #3 Gates-Glidden drills in distoaxial direction at 1 to 3 mm distance from the furcation. The canals were filled with gutta-percha and AH26 sealer with lateral compaction technique. The teeth were then mounted in dry bovine mandible and underwent CBCT using Acteon and NewTom CBCT systems. The CBCT scans were evaluated by two observers, and the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of the two CBCT systems for detection of strip perforation were determined and compared using the Chi-square test. Results: The sensitivity and specificity for detection of strip perforation were 51.3% and 46.3% for Acteon, and 55% and 38.8% for New -Tom CBCT system, respectively. The difference between the two CBCT systems for detection of strip perforation was not significant (Chi-square test, P>0.05). Conclusions: The accuracy of Acteon and New -Tom CBCT systems for detection of strip perforation is low, and no significant difference was noted between the two systems in this respect.
引用
收藏
页码:63 / 68
页数:6
相关论文
共 21 条
[1]  
Adel M, 2014, J J RES DENT SCI, V11, P103
[2]  
Bryant S, 1999, SHAPING ABILITY 04 0, P155
[3]  
Carvalho-Sousa Bruno, 2010, Eur J Dent, V4, P251
[4]   A New Periapical Index Based on Cone Beam Computed Tomography [J].
Estrela, Carlos ;
Bueno, Mike Reis ;
Azevedo, Bruno Correa ;
Azevedo, Jose Ribamar ;
Pecora, Jesus Djalma .
JOURNAL OF ENDODONTICS, 2008, 34 (11) :1325-1331
[5]   Electronic apex locators [J].
Gordon, MPJ ;
Chandler, NP .
INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (07) :425-437
[6]   Comparison of Five Cone Beam Computed Tomography Systems for the Detection of Vertical Root Fractures [J].
Hassan, Bassam ;
Metska, Maria Elissavet ;
Ozok, Ahmet Rifat ;
van der Stelt, Paul ;
Wesselink, Paul Rudolf .
JOURNAL OF ENDODONTICS, 2010, 36 (01) :126-129
[7]   Detection of Vertical Root Fractures in Endodontically Treated Teeth by a Cone Beam Computed Tomography Scan [J].
Hassan, Bassam ;
Metska, Maria Elissavet ;
Ozok, Ahmet Rifat ;
van der Stelt, Paul ;
Wesselink, Paul Rudolf .
JOURNAL OF ENDODONTICS, 2009, 35 (05) :719-722
[8]   Evaluation of Root and Canal Systems of Mandibular First Molars in Taiwanese Individuals Using Cone-beam Computed Tomography [J].
Huang, Chih-Chia ;
Chang, Ya-Chi ;
Chuang, Meng-Che ;
Lai, Tat-Minc ;
Lai, Juin-Yih ;
Lee, Bor-Shiunn ;
Lin, Chun-Pin .
JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2010, 109 (04) :303-308
[9]  
INGLE J I, 1961, Oral Surg Oral Med Oral Pathol, V14, P83, DOI 10.1016/0030-4220(61)90477-7
[10]   Modern endodontic surgery concepts and practice: A review [J].
Kim, Syngcuk ;
Kratchman, Samuel .
JOURNAL OF ENDODONTICS, 2006, 32 (07) :601-623