Cell manipulation with magnetic particles toward microfluidic cytometry

被引:96
作者
Liu, Chengxun [1 ,2 ]
Stakenborg, Tim [1 ]
Peeters, Sara [1 ]
Lagae, Liesbet [1 ]
机构
[1] Interuniv Microelect Ctr IMEC, B-3001 Heverlee, Belgium
[2] Katholieke Univ Leuven, Dept Elect Engn ESAT, B-3000 Louvain, Belgium
关键词
biomagnetism; bioMEMS; cellular biophysics; lab-on-a-chip; magnetic particles; magnetic separation; microfluidics; MICRO FLOW CYTOMETERS; BLOOD-CELLS; MAGNETOPHORETIC SEPARATION; TUMOR-CELLS; BEAD; TRANSPORT; PLATFORM; FORCE; ELECTROMAGNETS; SPECTROSCOPY;
D O I
10.1063/1.3116091
中图分类号
O59 [应用物理学];
学科分类号
摘要
Magnetic particles have become a promising tool for nearly all major lab-on-a-chip (LOC) applications, from sample capturing, purification, enrichment, transport to detection. For biological applications, the use of magnetic particles is especially well established for immunomagnetic separation. There is a great amount of interest in the automation of cell sorting and counting with magnetic particles in LOC platforms. So far, despite great efforts, only few fully functional LOC devices have been described and further integration is necessary. In this review, we will describe the physics of magnetic cell sorting and counting in LOC formats with a special focus on recent progress in the field.
引用
收藏
页数:11
相关论文
共 109 条
[1]  
[Anonymous], 1991, LOW REYNOLDS NUMBER
[2]   Resistance to nonspecific protein adsorption by poly(vinyl alcohol) thin films adsorbed to a poly(styrene) support matrix studied using surface plasmon resonance [J].
Barrett, DA ;
Hartshorne, MS ;
Hussain, MA ;
Shaw, PN ;
Davies, MC .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5232-5239
[3]  
Bozorth R.M., 1993, Ferromagnetism
[4]   Simultaneous bioassays in a microfluidic channel on plugs of different magnetic particles [J].
Bronzeau, Sandrine ;
Pamme, Nicole .
ANALYTICA CHIMICA ACTA, 2008, 609 (01) :105-112
[5]   Detection of 130 nm magnetic particles by a portable electronic platform using spin valve and magnetic tunnel junction sensors [J].
Cardoso, F. A. ;
Germano, J. ;
Ferreira, R. ;
Cardoso, S. ;
Martins, V. C. ;
Freitas, P. P. ;
Piedade, M. S. ;
Sousa, L. .
JOURNAL OF APPLIED PHYSICS, 2008, 103 (07)
[6]  
Chalmers JJ, 1998, BIOTECHNOL BIOENG, V59, P10, DOI 10.1002/(SICI)1097-0290(19980705)59:1<10::AID-BIT3>3.0.CO
[7]  
2-W
[8]   Investigating the feasibility of stem cell enrichment mediated by immobilized selectins [J].
Charles, Nichola ;
Liesveld, Jane L. ;
King, Michael R. .
BIOTECHNOLOGY PROGRESS, 2007, 23 (06) :1463-1472
[9]   Detection of Campylobacter jejuni in poultry samples using an enzyme-linked immunoassay coupled with an enzyme electrode [J].
Che, YH ;
Li, YB ;
Slavik, M .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12) :791-797
[10]   Ultrasensitive magnetic biosensor for homogeneous immunoassay [J].
Chemla, YR ;
Crossman, HL ;
Poon, Y ;
McDermott, R ;
Stevens, R ;
Alper, MD ;
Clarke, J .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (26) :14268-14272