Modified Septic Tank: Innovative Onsite Wastewater Treatment System

被引:21
作者
Abbassi, Bassim E. [1 ]
Abuharb, Raihan [2 ]
Ammary, Bashaar [2 ]
Almanaseer, Naser [2 ]
Kinsley, Christopher [3 ]
机构
[1] Univ Guelph, Sch Engn, Guelph, ON N1G 2W1, Canada
[2] Al Balqa Appl Univ, Dept Water Resources & Environm Management, Al Salt 19117, Jordan
[3] Univ Ottawa, Dept Civil Engn, Ottawa, ON K1N 6N5, Canada
关键词
onsite wastewater treatment; decentralized wastewater; septic tank; aerobic; anaerobic; attached growth; suspended growth; MANAGEMENT; COUNTRIES; REACTOR; REUSE;
D O I
10.3390/w10050578
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This research documents two innovative designs of septic tanks used for onsite wastewater treatment. The designs were implemented and tested as part of a research project focused on innovative decentralized wastewater treatment solutions. The modified septic tanks were tested at different hydraulic loading rates for sufficient periods to effectively evaluate their performance. The two systems were designed with successive anaerobic and aerobic chambers and were differentiated between attached and suspended growth. The systems were operated at detention times of 4.3, 3.2, and 2.6 days. High removal of organic load was achieved under all loading criteria in both systems. Effluent BOD5 concentration at lower and higher loading rates were found to be less than 15 and 25 mg/L, respectively, representing a removal rate of more than 95%. Nitrogen was also removed but at a lower rate. The highest TN removal was achieved (59%) in the attached growth system at the lowest loading rate. Although two logs of E. coli removal (99%) were achieved in all systems, E. coli numbers were high enough to necessitate further tertiary treatment. The modified septic tanks proved to be a cost-effective technology with low energy and O&M requirements.
引用
收藏
页数:11
相关论文
共 33 条
[1]  
Abbassi B., 2008, HDB EFFICIENTMANAGEM, V1st, P29
[2]  
Abbassi BE, 2008, J FOOD AGRIC ENVIRON, V6, P518
[3]   Effectiveness of onsite wastewater reuse system in reducing bacterial contaminants measured with human-specific IMS/ATP and qPCR [J].
Agidi, Senyo ;
Vedachalam, Sridhar ;
Mancl, Karen ;
Lee, Jiyoung .
JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2013, 115 :167-174
[4]   Evidence of septic system failure determined by a bacterial biochemical fingerprinting method [J].
Ahmed, W ;
Neller, R ;
Katouli, M .
JOURNAL OF APPLIED MICROBIOLOGY, 2005, 98 (04) :910-920
[5]   Modified septic tank treatment system [J].
Anil, Rrtu ;
Neera, Anand Lali .
INTERNATIONAL CONFERENCE ON EMERGING TRENDS IN ENGINEERING, SCIENCE AND TECHNOLOGY (ICETEST - 2015), 2016, 24 :240-247
[6]  
[Anonymous], 2005, Standard methods for the examination of water and waste- water
[7]   Preliminary Study on the Effect of Wastewater Storage in Septic Tank on E. coli Concentration in Summer [J].
Appling, Dominique ;
Habteselassie, Mussie Y. ;
Radcliffe, David ;
Bradshaw, James K. .
WATER, 2013, 5 (03) :1141-1151
[8]   Emerging organic contaminant removal depending on primary treatment and operational strategy in horizontal subsurface flow constructed wetlands: Influence of redox [J].
Avila, Cristina ;
Reyes, Carolina ;
Maria Bayona, Josep ;
Garcia, Joan .
WATER RESEARCH, 2013, 47 (01) :315-325
[9]  
Bradley RB., 2002, Clean Technologies and Environmental Policy, V4, P87, DOI DOI 10.1007/S10098-001-0130-Y
[10]  
Capodaglio AG, 2017, RESOURCES-BASEL, V6, DOI 10.3390/resources6020022