Evaluation of graft-host interface after penetrating keratoplasty using anterior segment optical coherence tomography

被引:21
作者
Sung, Mi Sun [1 ]
Yoon, Kyung Chul [1 ]
机构
[1] Chonnam Natl Univ, Med Sch & Hosp, Dept Ophthalmol, Ctr Creat Biomed Scientists, Donggu 501757, Gwangju, South Korea
关键词
Anterior segment optical coherence tomography; Penetrating keratoplasty; Corneal scar; Bullous keratopathy; Keratoconus; SUTURE REMOVAL; ASTIGMATISM; KERATOCONUS;
D O I
10.1007/s10384-014-0309-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To evaluate the characteristics of the graft-host interface after penetrating keratoplasty (PKP) using anterior segment optical coherence tomography (AS-OCT). Forty-nine eyes of 49 patients with three different underlying diseases (corneal scar, 22 eyes; bullous keratopathy, 14 eyes; keratoconus, 13 eyes) who underwent PKP were retrospectively reviewed. AS-OCT was performed in all patients and wound profiles of the graft-host junctions were classified into well-apposed junction, gap, step, and protrusion. The correlations between clinical characteristics and wound profiles from the AS-OCT were analyzed. A total of 392 graft-host junctions from 49 eyes were analyzed. Among them, 155 sections (39.5 %) had well-apposed junctions and 237 sections (60.5 %) had malapposed junctions. The most frequent type of malapposition was protrusion (117 sections, 39.9 %). When categorizing the eyes according to the most frequent alignment type among the 8 cross-sections, the alignment pattern showed significant differences between the preoperative diagnosis groups (P = 0.04). Spherical equivalent (P = 0.04) and keratometric astigmatism (P < 0.01) showed significant differences between the alignment groups. Graft-host thickness disparities showed significant correlations with keratometric astigmatism (r = 0.56, P < 0.01) and degree of graft oversize (r = 0.29, P = 0.04). The alignment pattern of wound interface after PKP differed according to the clinical diagnosis before surgery and was significantly associated with spherical equivalent and keratometric astigmatism.
引用
收藏
页码:282 / 289
页数:8
相关论文
共 17 条
[1]   THE EFFECT OF SUTURE REMOVAL ON POSTKERATOPLASTY ASTIGMATISM [J].
BINDER, PS .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1988, 105 (06) :637-645
[2]   Results of penetrating keratoplasty performed with a femtosecond laser zigzag incision initial report [J].
Farid, Marjan ;
Kim, Matthew ;
Steinert, Roger F. .
OPHTHALMOLOGY, 2007, 114 (12) :2208-2212
[3]  
Garner A., 1984, CORNEAL GRAFTING, P27
[4]   Ten-year postoperative results of penetrating keratoplasty [J].
Ing, JJ ;
Ing, HH ;
Nelson, LR ;
Hodge, DO ;
Bourne, WM .
OPHTHALMOLOGY, 1998, 105 (10) :1855-1865
[5]   Anterior Segment Optical Coherence Tomography [J].
Jancevski, Maria ;
Foster, C. Stephen .
SEMINARS IN OPHTHALMOLOGY, 2010, 25 (5-6) :317-323
[6]   Evaluation of Posterior Wound Profile After Penetrating Keratoplasty Using Anterior Segment Optical Coherence Tomography [J].
Jhanji, Vishal ;
Constantinou, Marios ;
Beltz, Jacqueline ;
Vajpayee, Rasik B. .
CORNEA, 2011, 30 (03) :277-280
[7]   Corneal wound malapposition after penetrating keratoplasty: an optical coherence tomography study [J].
Kaiserman, I. ;
Bahar, I. ;
Rootman, D. S. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2008, 92 (08) :1103-1107
[8]   CLINICOPATHOLOGICAL STUDIES OF KERATOPLASTY EYES OBTAINED POSTMORTEM [J].
LANG, GK ;
GREEN, WR ;
MAUMENEE, AE .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1986, 101 (01) :28-40
[9]   Penetrating keratoplasty for keratoconus: Visual outcome and success [J].
Lim, L ;
Pesudovs, K ;
Coster, DJ .
OPHTHALMOLOGY, 2000, 107 (06) :1125-1131
[10]   Corneal imaging with anterior segment optical coherence tomography for lamellar keratoplasty procedures [J].
Lim, Laurence S. ;
Aung, Han T. ;
Aung, Tin ;
Tan, Donald T. H. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (01) :81-90