Anterior chamber depth measurements in phakic and pseudophakic eyes: Pentacam versus ultrasound device

被引:59
作者
Nemeth, Gabor [1 ]
Vajas, Attila [1 ]
Kolozsvari, Bence [1 ]
Berta, Andras [1 ]
Modis, Laszlo [1 ]
机构
[1] Univ Debrecen, Med & Hlth Sci Ctr, Dept Ophthalmol, H-4012 Debrecen, Hungary
关键词
D O I
10.1016/j.jcrs.2006.02.057
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare anterior chamber depth (ACD) measurements with a new optical device with those taken with a standard ultrasound (US) device in emmetropic phakic and pseudophakic eyes. SETTING: Department of Ophthalmology, Medical Health and Science Center, University of Debrecen, Debrecen, Hungary. METHODS: Forty-two phakic and 42 pseudophakic patients with normal axial lengths (mean 22.91 mm +/- 1.21 [SD]) were enrolled in the study. The ACD was measured 3 times with Scheimpflug-based Pentacam (Oculus) and then 3 times with a standard A-scan US device (AL-2000, Tomey). The data were then analyzed. RESULTS: In the phakic group, the mean ACID was 2.87 +/- 0.4 mm with the Pentacam and 2.89 +/- 0.49 mm with ultrasound A-scan (US) (P =.84). In the pseudophakic group, the mean ACD was 3.41 +/- 0.28 mm and 3.97 +/- 0.45 mm, respectively (P<.001). The correlation between measurements was significant in both the phakic and pseudophakic groups (r =.547/P<.001 and r =.404/P =.01, respectively). CONCLUSIONS: In phakic eyes, ACD measured with the Pentacam and with US was the same. However, in pseudophakic eyes, the difference was significantly lower when the ACD was measured with the Pentacam. Therefore, in pseudophakic patients, further evaluation of ACD data with the Scheimpflug-based system is necessary.
引用
收藏
页码:1331 / 1335
页数:5
相关论文
共 24 条
[1]   Measuring anterior chamber depth with the Orbscan Topography System [J].
Auffarth, GU ;
Tetz, MR ;
Biazid, Y ;
Volcker, HE .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (09) :1351-1355
[2]   Measurement of the internal diameter and depth of the anterior chamber: IOLMaster versus anterior chamber optical coherence tomographer [J].
Baikoff, G ;
Jodai, HJ ;
Bourgeon, G .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) :1722-1728
[3]  
BOKER T, 1995, OPHTHALMIC RES, V27, P104
[4]   A proposed simple method for measurement in the anterior chamber angle -: Biometric gonioscopy [J].
Congdon, NG ;
Spaeth, GL ;
Augsburger, J ;
Klancnik, J ;
Patel, K ;
Hunter, DG .
OPHTHALMOLOGY, 1999, 106 (11) :2161-2167
[5]  
Devereux JG, 2000, ARCH OPHTHALMOL-CHIC, V118, P257
[6]   Magnetic resonance imaging and Orbscan assessment of the anterior chamber [J].
Fea, AM ;
Annetta, F ;
Cirillo, S ;
Campanella, D ;
De Giuseppe, M ;
Regge, D ;
Grignolo, FM .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) :1713-1718
[7]   Intraocular lens movement caused by ciliary muscle contraction [J].
Findl, O ;
Kiss, B ;
Petternel, V ;
Menapace, R ;
Georgopoulos, M ;
Rainer, G ;
Drexler, W .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (04) :669-676
[8]   A prospective ultrasound biomicroscopy evaluation of changes in anterior segment morphology after laser iridotomy in Asian eyes [J].
Gazzard, G ;
Friedman, DS ;
Devereux, JG ;
Chew, P ;
Seah, SKL .
OPHTHALMOLOGY, 2003, 110 (03) :630-638
[9]   COMPARISON OF A-SCAN DEVICE ACCURACY [J].
GIERS, U ;
EPPLE, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (02) :235-242
[10]   BIOMETRY OF 7,500 CATARACTOUS EYES [J].
HOFFER, KJ .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1980, 90 (03) :360-368