A simple approach to X-ray spectrometry with driftless gas proportional scintillation counters

被引:0
作者
Simoes, PCPS [1 ]
Covita, DS [1 ]
Monteiro, CMB [1 ]
dos Santos, JMF [1 ]
Morgado, RE [1 ]
机构
[1] Univ Coimbra, Dept Phys, P-3004516 Coimbra, Portugal
来源
2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4 | 2002年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Driftless gas proportional scintillation counters are used not only for soft x-ray spectrometry but also for x-rays with energies in the 0.1- to 25-keV region. At the higher energies, however, pulse amplitudes will depend on where the absorption occurred in the detector. Pulse-shape analysis with either analog or digital pulse techniques is required to restore proportionality between the measured pulse and the energy of the x-ray. In this work we describe a simpler approach to driftless gas proportional scintillation counter spectrometry at higher energies. The method eliminates the requirement for additional analog electronics or digital signal processing with only a modest amount of energy-dependent degradation in overall performance. The approach relies on short amplifier time constants and allows tradeoffs in the design of x-ray spectrometers whose performance requirements do not justify the complexity of a fully compensated system. We report the results of a comprehensive study of the performance characteristics of a driftless GPSC using short time constants with no additional compensation and compare its performance with that of a fully compensated digital system as a function of x-ray energy.
引用
收藏
页码:289 / 293
页数:5
相关论文
共 12 条
[1]  
BARBERA M, 1994, P SOC PHOTO-OPT INS, V2280, P154, DOI 10.1117/12.186809
[2]   DISTORTION EFFECTS IN SOFT-X-RAY ENERGY-SPECTRA FOR XENON GASEOUS DETECTORS - A MONTE-CARLO SIMULATION STUDY [J].
DIAS, THVT ;
SANTOS, FP ;
STAUFFER, AD ;
CONDE, CAN .
PHYSICAL REVIEW A, 1992, 46 (01) :237-245
[3]  
DOSSANTOS JMF, 2001, IN PRESS XRAY SPECTR, V30
[4]  
Policarpo A. J. P. L., 1977, Space Science Instrumentation, V3, P77
[5]   PULSE-HEIGHT-SPECTRUM DISTORTION IN XENON GASEOUS DETECTORS FOR SOFT X-RAYS - EXPERIMENTAL RESULTS [J].
SANTOS, FP ;
DOSSANTOS, JMF ;
DIAS, THVT ;
CONDE, CAN .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :611-614
[6]   Single event gate rupture in thin gate oxides [J].
Sexton, FW ;
Fleetwood, DM ;
Shaneyfelt, MR ;
Dodd, PE ;
Hash, GL .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (06) :2345-2352
[7]   Driftless gas proportional scintillation counter pulse analysis using digital processing techniques [J].
Simoes, PCPS ;
dos Santos, JMF ;
Conde, CAN .
X-RAY SPECTROMETRY, 2001, 30 (05) :342-347
[8]   SOFT-X-RAY ENERGY RESOLUTION AND BACKGROUND REJECTION IN A DRIFTLESS GAS SCINTILLATION PROPORTIONAL COUNTER [J].
SIMONS, DG ;
DEKORTE, PAJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 277 (2-3) :642-656
[9]  
SIMONS DG, 1985, SPIE, V597, P190
[10]   GAS-PRESSURE AND REDUCED ELECTRIC-FIELD EFFECTS IN GAS SCINTILLATION PROPORTIONAL-COUNTERS [J].
SMITH, A ;
FAVATA, F ;
KOWALSKI, TZ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 284 (2-3) :375-380