Spectra-resolved technique of a sensitive time-resolved fluorescence immunoassay instrument

被引:0
|
作者
Guo, ZY [1 ]
Tian, Z [1 ]
Jia, YL [1 ]
机构
[1] S China Normal Univ, Inst Laser Life Sci, Guangzhou 510631, Peoples R China
来源
ALT'03 INTERNATIONAL CONFERENCE ON ADVANCED LASER TECHNOLOGIES: BIOMEDICAL OPTICS | 2003年 / 5486卷
关键词
spectra-resolved technology; time-resolved fluorescence; immunoassay; lanthanide;
D O I
10.1117/12.572442
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The lanthanide trivalence ion and its chelates are used for marking substance in time-resolved fluorescence immunoassay (TRFIA), marking the protein, hormone, antibody, nucleic acid probe or biologic alive cell, to measure the concentration of the analysis substance inside the reaction system with time-resolved fluorometry after the reaction system occurred, and attain the quantitative analysis's purpose. TRFIA has been become a kind of new and more sensitive measure method after radioisotope marking, enzymatic marking, chemiluminescence, electrochemiluminescence, it primarily is decided by the special physics and chemistry characteristic of lanthanide trivalence ion and its chelates. In this paper, the result of spectroscopic evaluation of europium trivalence ion and its chelate, and the principle of spectra-resolved technology and a sensitive time-resolved fluorescence immunoassay instrument made by ourselves are reported. In the set, a high frequency Xenon pulsed-light was adopted as exciting light, and two special filters was utilized according to spectra-resolved technique. Thus the influence of scattering light and short-lifetime fluorescence was removed. And the sensitivity is 10(-12)mol/L (when Eu3+ was used for marking substance), examination repeat is CVless than or equal to5 %, examination linearity is from 10 (-8) mol/L to 10(-12)mol/L, correlation coefficient rgreater than or equal to95%(p<0.01).
引用
收藏
页码:222 / 226
页数:5
相关论文
共 50 条
  • [1] Development of a multipurpose time-resolved fluorescence immunoassay for rat insulin
    van Genderen, Farah T.
    Gorus, Frans K.
    Vermeulen, Ilse
    Vekens, Evilien M. F.
    De Pauw, Pieter E. M.
    Pipeleers, Daniel G.
    Van Schravendijk, Chris
    ANALYTICAL BIOCHEMISTRY, 2010, 404 (01) : 8 - 13
  • [2] A time-resolved fluorescence immunoassay for insulin in rodent plasma
    Daijo, JE
    Sportsman, JR
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 19 (3-4) : 335 - 342
  • [3] Total error profiling of a proinsulin time-resolved fluorescence immunoassay
    De Pauw, P. E.
    Mackin, R. B.
    Goubert, R.
    Van Schravendijk, C.
    Gorus, F. K.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (23): : 2403 - 2406
  • [4] Sensitive Listeria spp. immunoassay based on europium(III) nanoparticulate labels using time-resolved fluorescence
    Jaakohuhta, Sinikka
    Harma, Harri
    Tuomola, Mika
    Lovgren, Timo
    INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2007, 114 (03) : 288 - 294
  • [5] IMMUNOASSAY BY TIME-RESOLVED ELECTROGENERATED LUMINESCENCE
    KANKARE, J
    HAAPAKKA, K
    KULMALA, S
    NANTO, V
    ESKOLA, J
    TAKALO, H
    ANALYTICA CHIMICA ACTA, 1992, 266 (02) : 205 - 212
  • [6] Immunoassay System Based on the Technology of Time-Resolved Fluorescence Resonance Energy Transfer
    Xu, Zhengping
    Zhou, Hong
    Li, Li
    Chen, Zhang
    Zhang, Xin
    Feng, Yongtong
    Wang, Jianping
    Li, Yuan
    Wu, Yanfan
    SENSORS, 2024, 24 (05)
  • [7] Sensitive miniature single-particle immunoassay of prostate-specific antigen using time-resolved fluorescence
    Härmä, H
    Pelkkikangas, AM
    Soukka, T
    Huhtinen, P
    Huopalahti, S
    Lövgren, T
    ANALYTICA CHIMICA ACTA, 2003, 482 (02) : 157 - 164
  • [8] Time-resolved fluorescence of hemoglobin species
    Gryczynski, Z
    Beretta, S
    Lubkowski, J
    Razynska, A
    Gryczynski, I
    Bucci, E
    BIOPHYSICAL CHEMISTRY, 1997, 64 (1-3) : 81 - 91
  • [9] Time-Resolved Fluorescence in Photodynamic Therapy
    Yeh, Shu-Chi Allison
    Patterson, Michael S.
    Hayward, Joseph E.
    Fang, Qiyin
    PHOTONICS, 2014, 1 (04) : 530 - 564
  • [10] Fast photomultiplier tube gating technique for time-resolved fluorescence measurements
    Zipfl, P
    Schneckenburger, H
    Schoch, L
    BIOMEDICAL IMAGING: REPORTERS, DYES, AND INSTRUMENTATION, PROCEEDINGS OF, 1999, 3600 : 158 - 164