摘要
There is evidence that subtle breakdown of the blood-brain barrier (BBB) is a pathophysiological component of several diseases, including cerebral small vessel disease and some dementias. Dynamic contrast-enhanced MRI (DCE-MRI) combined with tracer kinetic modelling is widely used for assessing permeability and perfusion in brain tumours and body tissues where contrast agents readily accumulate in the extracellular space. However, in diseases where leakage is subtle, the optimal approach for measuring BBB integrity is likely to differ since the magnitude and rate of enhancement caused by leakage are extremely low; several methods have been reported in the literature, yielding a wide range of parameters even in healthy subjects. We hypothesised that the Patlak model is a suitable approach for measuring low-level BBB permeability with low temporal resolution and high spatial resolution and brain coverage, and that normal levels of scanner instability would influence permeability measurements. DCE-MRI was performed in a cohort of mild stroke patients (n = 201) with a range of cerebral small vessel disease severity. We fitted these data to a set of nested tracer kinetic models, ranking their performance according to the Akaike information criterion. To assess the influence of scanner drift, we scanned 15 healthy volunteers that underwent a "sham" DCE-MRI procedure without administration of contrast agent. Numerical simulations were performed to investigate model validity and the effect of scanner drift. The Patlak model was found to be most appropriate for fitting low-permeability data, and the simulations showed vp and K-Trans estimates to be reasonably robust to the model assumptions. However, signal drift (measured at approximately 0.1% perminute and comparable to literature reports in other settings) led to systematic errors in calculated tracer kinetic parameters, particularly at low permeabilities. Our findings justify the growing use of the Patlak model in low-permeability states, which has the potential to provide valuable information regarding BBB integrity in a range of diseases. However, absolute values of the resulting tracer kinetic parameters should be interpreted with extreme caution, and the size and influence of signal drift should be measured where possible. (C) 2015 The Authors. Published by Elsevier Inc.
引用
收藏
页码:446 / 455
页数:10
相关论文
共 61 条
  • [11] Multimodel inference - understanding AIC and BIC in model selection
    Burnham, KP
    Anderson, DR
    [J]. SOCIOLOGICAL METHODS & RESEARCH, 2004, 33 (02) : 261 - 304
  • [12] Abnormal blood-brain barrier permeability in normal appearing white matter in multiple sclerosis investigated by MRI
    Cramer, S. P.
    Simonsen, H.
    Frederiksen, J. L.
    Rostrup, E.
    Larsson, H. B. W.
    [J]. NEUROIMAGE-CLINICAL, 2014, 4 : 182 - 189
  • [13] Accurate determination of blood brain barrier permeability using dynamic contrast-enhanced T1-weighted MRI: a simulation and in vivo study on healthy subjects and multiple sclerosis patients
    Cramer, Stig P.
    Larsson, Henrik B. W.
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2014, 34 (10) : 1655 - 1665
  • [14] High-resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high-speed incorporation of RF field inhomogeneities (DESPOT1-HIFI)
    Deoni, Sean C. L.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (04) : 1106 - 1111
  • [15] Blood-brain barrier: Ageing and microvascular disease-systematic review and meta-analysis
    Farrall, Andrew J.
    Wardlaw, Joanna M.
    [J]. NEUROBIOLOGY OF AGING, 2009, 30 (03) : 337 - 352
  • [16] Development and initial testing of normal reference MR images for the brain at ages 65-70 and 75-80 years
    Farrell, C.
    Chappell, F.
    Armitage, P. A.
    Keston, P.
    MacLullich, A.
    Shenkin, S.
    Wardlaw, J. M.
    [J]. EUROPEAN RADIOLOGY, 2009, 19 (01) : 177 - 183
  • [17] Report on a multicenter fMRI quality assurance protocol
    Friedman, L
    Glover, GH
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (06) : 827 - 839
  • [18] Increased blood-brain barrier permeability in white matter lesions of Binswanger's disease evaluated by contrast-enhanced MRI
    Hanyu, H
    Asano, T
    Tanaka, Y
    Iwamoto, T
    Takasaki, M
    Abe, K
    [J]. DEMENTIA AND GERIATRIC COGNITIVE DISORDERS, 2002, 14 (01) : 1 - 6
  • [19] Assessment of blood-brain barrier disruption using dynamic contrast-enhanced MRI. A systematic review
    Heye, Anna K.
    Culling, Ross D.
    Valdes Hernandez, Maria del C.
    Thrippleton, Michael J.
    Wardlaw, Joanna M.
    [J]. NEUROIMAGE-CLINICAL, 2014, 6 : 262 - 274
  • [20] DRIVEN-EQUILIBRIUM SINGLE-PULSE OBSERVATION OF T1 RELAXATION - A REEVALUATION OF A RAPID NEW METHOD FOR DETERMINING NMR SPIN-LATTICE RELAXATION-TIMES
    HOMER, J
    BEEVERS, MS
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1985, 63 (02) : 287 - 297