A Robotic Ultrasound Scanner for Automatic Vessel Tracking and Three-Dimensional Reconstruction of B-Mode Images

被引:38
作者
Merouche, Samir [1 ,2 ]
Allard, Louise [1 ]
Montagnon, Emmanuel [1 ,2 ]
Soulez, Gilles [2 ,3 ,4 ]
Bigras, Pascal [5 ]
Cloutier, Guy [1 ,2 ,4 ]
机构
[1] Univ Montreal Hosp CRCHUM, Res Ctr, Lab Biorheol & Med Ultrason, Montreal, PQ H2X 0A9, Canada
[2] Univ Montreal, Inst Biomed Engn, Montreal, PQ H3T 1J4, Canada
[3] Univ Montreal Hosp CHUM, Dept Radiol, Montreal, PQ H2L 4M1, Canada
[4] Univ Montreal, Dept Radiol Radiooncol & Nucl Med, Montreal, PQ H3T 1J4, Canada
[5] Univ Quebec, Ecole Technol Super, Dept Automated Mfg Engn, Montreal, PQ H3C 1K3, Canada
关键词
Image reconstruction; medical robotics; robotics and automation; ultrasonic imaging; ultrasonography; LIMB ARTERIAL STENOSES; CAROTID PLAQUE VOLUME; IN-VITRO; CALIBRATION; ULTRASONOGRAPHY; QUANTIFICATION; PHANTOM; SYSTEM;
D O I
10.1109/TUFFC.2015.2499084
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Locating and evaluating the length and severity of a stenosis is very important for planning adequate treatment of peripheral arterial disease (PAD). Conventional ultrasound (US) examination cannot provide maps of entire lower limb arteries in 3-D. We propose a prototype 3D-US robotic system with B-mode images, which is nonionizing, noninvasive, and is able to track and reconstruct a continuous segment of the lower limb arterial tree between the groin and the knee. From an initialized cross-sectional view of the vessel, automatic tracking was conducted followed by 3D-US reconstructions evaluated using Hausdorff distance, cross-sectional area, and stenosis severity in comparison with 3-D reconstructions with computed tomography angiography (CTA). A mean Hausdorff distance of 0.97 +/- 0.46 mm was found in vitro for 3D-US compared with 3D-CTA vessel representations. To evaluate the stenosis severity in vitro, 3D-US reconstructions gave errors of 3%-6% when compared with designed dimensions of the phantom, which are comparable to 3D-CTA reconstructions, with 4%-13% errors. The in vivo system's feasibility to reconstruct a normal femoral artery segment of a volunteer was also investigated. These results encourage further ergonomic developments to increase the robot's capacity to represent lower limb vessels in the clinical context.
引用
收藏
页码:35 / 46
页数:12
相关论文
共 50 条
[31]   Improving three-dimensional automated breast ultrasound resolution with orthogonal images [J].
Park, Claire Keun Sun ;
Trumpour, Tiana ;
Gyacskovb, Igor ;
Baxb, Jeffrey ;
Tessierb, David ;
Gardib, Lori ;
Icoa, Madeline ;
Fenstera, Aaron .
MEDICAL IMAGING 2023, 2023, 12470
[32]   Three-dimensional weld seam tracking for robotic welding by composite sensing technology [J].
Wei, Shanchun ;
Kong, Meng ;
Lin, Tao ;
Chen, Shanben .
INDUSTRIAL ROBOT-THE INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH AND APPLICATION, 2011, 38 (05) :500-508
[33]   Three-Dimensional Reconstruction of Fuzzy Medical Images Using Quantum Algorithm [J].
Li, Xiaofeng ;
Sui, Jun ;
Wang, Yanwei .
IEEE ACCESS, 2020, 8 :218279-218288
[34]   Contribution of morphological by three-dimensional ultrasound malignancy in ovarian masses assessment of the vessel tree to a correct diagnosis of [J].
Sladkevicius, P. ;
Jokubkiene, L. ;
Valentin, L. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2007, 30 (06) :874-882
[35]   Application of texture analysis of b-mode ultrasound images for the quantification and prediction of intramuscular fat in living beef cattle: A methodological study [J].
Fiore, Enrico ;
Fabbri, Giorgia ;
Gallo, Luigi ;
Morgante, Massimo ;
Muraro, Michele ;
Boso, Matteo ;
Gianesella, Matteo .
RESEARCH IN VETERINARY SCIENCE, 2020, 131 :254-258
[36]   Texture analysis of B-mode ultrasound images to stage hepatic lipidosis in the dairy cow: A methodological study [J].
Banzato, Tommaso ;
Fiore, Enrico ;
Morgante, Massimo ;
Manuali, Elisabetta ;
Zotti, Alessandro .
RESEARCH IN VETERINARY SCIENCE, 2016, 108 :71-75
[37]   Unsupervised Test-Time Adaptation for Hepatic Steatosis Grading Using Ultrasound B-Mode Images [J].
Vianna, Pedro ;
Mehrbod, Paria ;
Chaudhary, Muawiz ;
Eickenberg, Michael ;
Wolf, Guy ;
Belilovsky, Eugene ;
Tang, An ;
Cloutier, Guy .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2025, 72 (05) :601-611
[38]   Low-cost quasi-real-time elastography using B-mode ultrasound images [J].
Kwon, Hyock-Ju ;
Lee, Jiwon .
BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (04) :1673-1692
[39]   A pulsating coronary vessel phantom for two- and three-dimensional intravascular ultrasound studies [J].
Nadkarni, SK ;
Austin, H ;
Mills, G ;
Boughner, D ;
Fenster, A .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (04) :621-628
[40]   In vivo evaluation of two-dimensional temperature variation in perirenal fat of pigs with B-mode ultrasound [J].
Fan, Pengfei ;
Yin, Chuhao ;
Xue, Honghui ;
Xie, Linzhou ;
Sun, Wei ;
Tu, Juan ;
Guo, Xiasheng ;
Kong, Xiangqing ;
Zhang, Dong .
JOURNAL OF APPLIED PHYSICS, 2019, 126 (08)