Visual Outcomes of Eyes Implanted With a Toric Multifocal Intraocular Lens

被引:9
作者
Crema, Armando S. [1 ]
Walsh, Aileen [1 ]
Ventura, Bruna V. [2 ,3 ]
Santhiago, Marcony R. [1 ,4 ,5 ]
机构
[1] Rio RioLaser Refract Surg Ctr, Rio De Janeiro, Brazil
[2] Baylor Coll Med, Cullen Eye Inst, Dept Ophthalmol, Houston, TX 77030 USA
[3] Altino Ventura Fdn, Recife, PE, Brazil
[4] Univ Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil
[5] Univ Fed Rio de Janeiro, Dept Ophthalmol, Rio De Janeiro, Brazil
关键词
CATARACT-SURGERY; VECTOR ANALYSIS; BILATERAL IMPLANTATION; ASTIGMATIC CHANGES; PERFORMANCE; CORNEAL; ERROR;
D O I
10.3928/1081597X-20140530-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the predictability, efficacy, and safety of a ReSTOR multifocal intraocular lens (IOL) (Alcon Laboratories, Inc., Fort Worth, TX). METHODS: This retrospective, noncomparative case study included 70 eyes of 44 patients implanted with a ReSTOR toric multifocal IOL (Alcon Laboratories, Inc., Fort Worth, TX). Patients were examined preoperatively and approximately 3 months postoperatively. Uncorrected and distance-corrected distance and near visual acuities were measured. Refractive and topographic astigmatism were recorded. Improvement, number of lines gained and lost, and correlation of attempted and achieved astigmatic correction values were also investigated as measurements of efficacy, safety, and predictability. RESULTS: Mean follow-up time was 2.3 +/- 1.2 months. Postoperative values of uncorrected distance and near visual acuity were 0.02 +/- 0.05 logMAR (20/21 +/- 20/22 Snellen) and 0.01 +/- 0.04 logMAR (20/20 +/- 20/22 Snellen), respectively. Statistical analyses revealed a significant improvement when comparing preoperative and postoperative values of manifest refraction spherical equivalent (P < .0001), uncorrected distance visual acuity (P < .0001), and astigmatism (P < .0001); 95.7% of eyes were 20/25 or better and 100% of eyes were 20/30 or better. At the last follow-up visit, none of the examined eyes had lost any lines. One hundred percent of the eyes remained unchanged or improved after surgery. Mean postoperative manifest refraction spherical equivalent was -0.06 +/- 0.27 at the last follow-up visit. The residual manifest astigmatism was 0.22 +/- 0.21. There was a highly significant correlation between preoperative attempted topographic astigmatism and postoperative achieved refractive astigmatism. CONCLUSIONS: The study provides clinical evidence that the new toric multifocal IOL seems to be predictable, safe, and effective, providing satisfactory visual acuity for far and near and correcting astigmatism.
引用
收藏
页码:486 / 491
页数:6
相关论文
共 16 条
[1]   Vector analysis of astigmatic changes after cataract surgery with implantation of a new toric multifocal intraocular lens [J].
Alio, Jorge L. ;
Pinero, David P. ;
Tomas, Javier ;
Plaza, Ana B. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (07) :1217-1229
[2]   Vector analysis of astigmatic changes after cataract surgery with toric intraocular lens implantation [J].
Alio, Jorge L. ;
Pinero, David P. ;
Tomas, Javier ;
Aleson, Alicia .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06) :1038-1049
[3]   Visual and optical outcomes of a diffractive multifocal toric intraocular lens [J].
Ferreira, Tiago B. ;
Marques, Eduardo F. ;
Rodrigues, Antonio ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (07) :1029-1035
[4]   Effect of astigmatism on visual acuity in eyes with a diffractive multifocal intraocular lens [J].
Hayashi, Ken ;
Manabe, Shin-ichi ;
Yoshida, Motoaki ;
Hayashi, Hideyuki .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (08) :1323-1329
[5]   Results of higher power toric intraocular lens implantation [J].
Hoffmann, Peter C. ;
Auel, Sebastian ;
Huetz, Werner W. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (08) :1411-1418
[6]   Analysis of aggregate surgically induced refractive change, prediction error, and intraocular astigmatism [J].
Holladay, JT ;
Moran, JR ;
Kezirian, GM .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (01) :61-79
[7]   Contribution of posterior corneal astigmatism to total corneal astigmatism [J].
Koch, Douglas D. ;
Ali, Shazia F. ;
Weikert, Mitchell P. ;
Shirayama, Mariko ;
Jenkins, Richard ;
Wang, Li .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (12) :2080-2087
[8]   Adhesion of fibronectin, vitronectin, laminin, and collagen type IV to intraocular lens materials in pseudophakic human autopsy eyes - Part 1: Histological sections [J].
Linnola, RJ ;
Werner, L ;
Pandey, SK ;
Escobar-Gomez, M ;
Znoiko, SL ;
Apple, DJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (12) :1792-1806
[9]   Rotational stability and posterior capsule opacification of a plate-haptic and an open-loop-haptic intraocular lens [J].
Prinz, Ana ;
Neumayer, Thomas ;
Buehl, Wolf ;
Vock, Lorenz ;
Menapace, Rupert ;
Findl, Oliver ;
Georgopoulos, Michael .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (02) :251-257
[10]   Modulation transfer function and optical quality after bilateral implantation of a+3.00 D versus a+4.00 D multifocal intraocular lens [J].
Santhiago, Marcony R. ;
Wilson, Steven E. ;
Netto, Marcelo V. ;
Ghanen, Ramon C. ;
Monteiro, Mario Luis R. ;
Bechara, Samir J. ;
Espana, Edgar M. ;
Mello, Glauco R. ;
Kara-Junior, Newton .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (02) :215-220