Nanoporous Membranes Enable Concentration and Transport in Fully Wet Paper-Based Assays

被引:76
作者
Gong, Max M. [1 ]
Zhang, Pei [1 ]
MacDonald, Brendan D. [2 ]
Sinton, David [1 ]
机构
[1] Univ Toronto, Dept Mech & Ind Engn, Toronto, ON M5S 3G8, Canada
[2] Univ Ontario, Inst Technol, Fac Engn & Appl Sci, Oshawa, ON L1H 7K4, Canada
基金
加拿大创新基金会; 加拿大自然科学与工程研究理事会;
关键词
CONCENTRATION POLARIZATION; PRECONCENTRATION DEVICE; ENHANCED SENSITIVITY; GOLD; PLATFORM;
D O I
10.1021/ac502597v
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Low-cost paper-based assays are emerging as the platform for diagnostics worldwide. Paper does not, however, readily enable advanced functionality required for complex diagnostics, such as analyte concentration and controlled analyte transport. That is, after the initial wetting, no further analyte manipulation is possible. Here, we demonstrate active concentration and transport of analytes in fully wet paper-based assays by leveraging nanoporous material (mean pore diameter approximate to 4 nm) and ion concentration polarization. Two classes of devices are developed, an external stamp-like device with the nanoporous material separate from the paper-based assay, and an in-paper device patterned with the nanoporous material. Experimental results demonstrate up to 40-fold concentration of a fluorescent tracer in fully wet paper, and directional transport of the tracer over centimeters with efficiencies up to 96%. In-paper devices are applied to concentrate protein and colored dye, extending their limits of detection from similar to 10 to similar to 2 pmol/mL and from similar to 40 to similar to 10 mu M, respectively. This approach is demonstrated in nitrocellulose membrane as well as paper, and the added cost of the nanoporous material is very low at similar to 0.015 USD per device. The result is a major advance in analyte concentration and manipulation for the growing field of low-cost paper-based assays.
引用
收藏
页码:8090 / 8097
页数:8
相关论文
共 46 条
[1]   DNA circuits as amplifiers for the detection of nucleic acids on a paperfluidic platform [J].
Allen, Peter B. ;
Arshad, Seyed A. ;
Li, Bingling ;
Chen, Xi ;
Ellington, Andrew D. .
LAB ON A CHIP, 2012, 12 (16) :2951-2958
[2]  
Bohm A., 2014, MICROFLUID NANOFLUID, P1
[4]   Enhanced Sensitivity of Lateral Flow Tests Using a Two-Dimensional Paper Network Format [J].
Fu, Elain ;
Liang, Tinny ;
Houghtaling, Jared ;
Ramachandran, Sujatha ;
Ramsey, Stephen A. ;
Lutz, Barry ;
Yager, Paul .
ANALYTICAL CHEMISTRY, 2011, 83 (20) :7941-7946
[5]   Transport in two-dimensional paper networks [J].
Fu, Elain ;
Ramsey, Stephen A. ;
Kauffman, Peter ;
Lutz, Barry ;
Yager, Paul .
MICROFLUIDICS AND NANOFLUIDICS, 2011, 10 (01) :29-35
[6]   Chemical signal amplification in two-dimensional paper networks [J].
Fu, Elain ;
Kauffman, Peter ;
Lutz, Barry ;
Yager, Paul .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 149 (01) :325-328
[7]   Controlled reagent transport in disposable 2D paper networks [J].
Fu, Elain ;
Lutz, Barry ;
Kauffman, Peter ;
Yager, Paul .
LAB ON A CHIP, 2010, 10 (07) :918-920
[8]   Lab-in-a-pen: a diagnostics format familiar to patients for low-resource settings [J].
Gong, Max M. ;
MacDonald, Brendan D. ;
Trung Vu Nguyen ;
Kinh Van Nguyen ;
Sinton, David .
LAB ON A CHIP, 2014, 14 (05) :957-963
[9]   Natural Cellulose Fiber as Substrate for Supercapacitor [J].
Gui, Zhe ;
Zhu, Hongli ;
Gillette, Eleanor ;
Han, Xiaogang ;
Rubloff, Gary W. ;
Hu, Liangbing ;
Lee, Sang Bok .
ACS NANO, 2013, 7 (07) :6037-6046
[10]   Ionic conductance of nanopores in microscale analysis systems:: Where microfluldics meets nanofluidics [J].
Hoeltzel, Alexandra ;
Tallarek, Ulrich .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (10) :1398-1419