Assessment of the nutritional state of dialysis patients

被引:36
作者
Kerr, PG
Strauss, BJG
Atkins, RC
机构
[1] Departments of Nephrology, Monash Medical Centre, Clayton
[2] Departments of Clinical Nutrition and Metabolism, Monash Medical Centre, Clayton
关键词
dialysis; nutrition; albumin; fat-free mass; DEXA;
D O I
10.1159/000170290
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The importance of the nutritional state of our dialysis patients has been stressed for many years. Although the calculation of the protein catabolic rate has become common practice in many dialysis units, there are several problems with this measurement. In addition, the serum albumin level is subject to multiple influences making its interpretation in individual patients difficult. This paper examines a different approach to nutritional assessment - that of using longer term measures of nutrition. Several techniques for measuring body composition are explored and their use in end-stage renal disease (ESRD) examined. Total body nitrogen measurement is a gold standard technique which has been validated in renal patients, unfortunately it is not widely available. Of the alternatives, dual energy X-ray absorptiometry scanning for assessment of fat-free mass appears to be the best technique with the narrowest limits of agreement compared to gold standard techniques. Whilst bioelectrical impedance is reasonable for body water assessment, it is not reliable in ESRD patients for lean-body mass estimation.
引用
收藏
页码:382 / 387
页数:6
相关论文
共 25 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
BOROVNICAR DJ, 1995, UNPUB FAT FREE MASS
[3]  
ELLIS KJ, 1982, J LAB CLIN MED, V99, P917
[4]   BODY-COMPOSITION FOLLOWING HEMODIALYSIS - STUDIES USING DUAL-ENERGY X-RAY ABSORPTIOMETRY AND BIOELECTRICAL-IMPEDANCE ANALYSIS [J].
FORMICA, C ;
ATKINSON, MG ;
NYULASI, I ;
MCKAY, J ;
HEALE, W ;
SEEMAN, E .
OSTEOPOROSIS INTERNATIONAL, 1993, 3 (04) :192-197
[5]   A MECHANISTIC ANALYSIS OF THE NATIONAL COOPERATIVE DIALYSIS STUDY (NCDS) [J].
GOTCH, FA ;
SARGENT, JA .
KIDNEY INTERNATIONAL, 1985, 28 (03) :526-534
[6]   BIOIMPEDANCE ANALYSIS OF TOTAL-BODY WATER IN HEMODIALYSIS-PATIENTS [J].
HO, LT ;
KUSHNER, RF ;
SCHOELLER, DA ;
GUDIVAKA, R ;
SPIEGEL, DM .
KIDNEY INTERNATIONAL, 1994, 46 (05) :1438-1442
[7]   DETERMINATION OF TOTAL-BODY WATER IN UREMIC PATIENTS BY BIOELECTRICAL-IMPEDANCE [J].
KONG, CH ;
THOMPSON, CM ;
LEWIS, CA ;
HILL, PD ;
THOMPSON, FD .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1993, 8 (08) :716-719
[8]  
KUSHNER RF, 1992, J AM COLL NUTR, V11, P199
[9]   EFFECT OF THE HEMODIALYSIS PRESCRIPTION ON PATIENT MORBIDITY - REPORT FROM THE NATIONAL COOPERATIVE DIALYSIS STUDY [J].
LOWRIE, EG ;
LAIRD, NM ;
PARKER, TF ;
SARGENT, JA .
NEW ENGLAND JOURNAL OF MEDICINE, 1981, 305 (20) :1176-1181
[10]   DEATH RISK IN HEMODIALYSIS-PATIENTS - THE PREDICTIVE VALUE OF COMMONLY MEASURED VARIABLES AND AN EVALUATION OF DEATH RATE DIFFERENCES BETWEEN FACILITIES [J].
LOWRIE, EG ;
LEW, NL .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1990, 15 (05) :458-482