X-ray cone-beam computed tomography geometric artefact reduction based on a data-driven strategy

被引:9
作者
Xiao, Kai [1 ]
Han, Yu [1 ]
Xu, Yifu [1 ]
Li, Lei [1 ]
Xi, Xiaoqi [1 ]
Bu, Haibing [1 ]
Yan, Bin [1 ]
机构
[1] Natl Digital Switching Syst Engn & Technol Res Ct, Zhengzhou 450000, Henan, Peoples R China
基金
中国国家自然科学基金;
关键词
CALIBRATION METHOD; MISALIGNMENT; PARAMETERS; ALIGNMENT; SYSTEM; CT;
D O I
10.1364/AO.58.004771
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Cone-beam computed tomography (CBCT) enables three-dimensional imaging of the internal structure of objects in a non-invasive way with high accuracy. Practical misalignment of the CBCT system causes geometric artefacts in reconstructed images, which seriously degrades image quality in ways such as detail loss and decreased spatial resolution. This leads to inaccurate distinction of defects in detection, especially in precise industrial fields like aerospace and instrument manufacturing. This paper presents a method to reduce the geometric artefacts based on a data-driven strategy, which is an end-to-end modified fully convolutional neural network (M-FCNN). The designed M-FCCN contains five convolution layers and five deconvolution layers for feature extraction and output image rebuilding, respectively. In addition, the pooling layer is not used in the designed M-FCNN, considering the preservation of details in the reconstructed image. In this M-FCCN, artefact images with different features have been trained separately. After training, the M-FCNN can be applied to directly reduce geometric artefacts in the reconstructed image. The designed M-FCNN has been demonstrated with different types of synthetic data and has achieved accurate results. It is also validated with practical data, including carbon composite and medical oral phantoms with comparable quality to phantom-based methods, proving that it is an effective way to reduce geometric artefacts in the image domain by means of a data-driven strategy. (C) 2019 Optical Society of America
引用
收藏
页码:4771 / 4780
页数:10
相关论文
共 31 条
[1]  
[Anonymous], IEEE T CYBERN
[2]  
[Anonymous], J SYNCHROTRON RAD
[3]  
[Anonymous], IEEE T MED IMAGING
[4]  
[Anonymous], P SPIE
[5]  
[Anonymous], IEEE ACCESS
[6]   Virtual alignment of x-ray cone-beam tomography system using two calibration aperture measurements [J].
Bronnikov, AV .
OPTICAL ENGINEERING, 1999, 38 (02) :381-386
[7]   Automated determination of the center of rotation in tomography data [J].
Donath, T ;
Beckmann, F ;
Schreyer, A .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2006, 23 (05) :1048-1057
[8]   Geometric calibration and correction for a lens-coupled detector in x-ray phase-contrast imaging [J].
George A. ;
Chen P.Y. ;
Morales-Martinez A. ;
Panna A. ;
Gomella A.A. ;
Bennett E.E. ;
Wen H. .
Journal of Medical Imaging, 2017, 4 (01)
[9]   Hybrid Imaging System for Simultaneous Spiral MR and X-ray (MRX) Scans [J].
Gjesteby, Lars ;
Xi, Yan ;
Kalra, Mannudeep K. ;
Yang, Qingsong ;
Wang, Ge .
IEEE ACCESS, 2017, 5 :1050-1061
[10]  
Goodfellow Ian, 2013, INT C MACH LEARN PML, P1319