Application of Engineered Cementitious Composites (ECC) in interior beam-column connections for enhanced seismic resistance

被引:189
作者
Qudah, Salahuddin [1 ]
Maalej, Mohamed [2 ]
机构
[1] Jordan Engineers Assoc, Tech Dept, Amman, Jordan
[2] Univ Sharjah, Dept Civil & Environm Engn, Sharjah, U Arab Emirates
关键词
Seismic resistance; Cyclic loading; Beam-column connection; Engineered; Cementitous Composites (ECC); Confinement; Plastic zone; FIBER-REINFORCED-CONCRETE; JOINTS; BEHAVIOR;
D O I
10.1016/j.engstruct.2014.03.026
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study aims to evaluate the feasibility of using ultra-ductile Engineered Cementitous Composites (ECC) as a means to enhance the performance of beam column connections. Nine one-third scale specimens, consisting of type 2 (ACI352R-02) interior connections at a zone of high seismicity (UBC-zone 3), were tested under reverse cyclic loading, simulating seismic excitation. The joints of these specimens were typical in geometry and main reinforcement detailing to specimens of a prototype building frame designed according to ACI318-08. The primary variables were the amount and arrangement of transverse reinforcements, and the materials within the plastic zone of the connection. The performances of a series of ECC-enhanced beam column interior connections were compared to that of a control concrete counterpart to evaluate the benefits of using ECC in this type of application. The column load displacement response (including the ultimate load and ultimate displacement), the (hysteresis) energy absorption capacity, and the cracking response were used as criteria in the comparison. The test results indicated that the use of ECC material in the connection plastic zone as a replacement of concrete and partial replacement of transverse (confinement) reinforcement can significantly enhance the joint shear resistance, energy absorption capacity, and cracking response, thereby, enhancing the joint seismic resistance and reducing reinforcement congestion and construction complexity. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:235 / 245
页数:11
相关论文
共 17 条
[1]   Seismic response of steel fibre reinforced concrete beam-column joints [J].
Abbas, Ali A. ;
Mohsin, Sharifah M. Syed ;
Cotsovos, Demetrios M. .
ENGINEERING STRUCTURES, 2014, 59 :261-283
[2]  
ACI Committee 318, 2008, 318 ACI COMM
[3]  
[Anonymous], 1997, UNIFORM BUILDING COD, V2
[4]  
Earthquake Engineering Research Institute, 1999, ATH GREEC EARTHQ SEP
[5]  
Earthquake Engineering Research Institutea, 1999, TEH MEX EARTHQ JUN 1
[6]   Seismic rehabilitation of beam-column joint using GFRP sheets [J].
El-Amoury, T ;
Ghobarah, A .
ENGINEERING STRUCTURES, 2002, 24 (11) :1397-1407
[7]  
FILIATRAULT A, 1995, ACI STRUCT J, V92, P543
[8]  
GEFKEN PR, 1989, ACI STRUCT J, V86, P168
[9]  
Joint ACI-ASCE Committee, 2002, 352 JOINT ACI ASCE C
[10]   Experimental investigation on reinforced concrete interior beam-column joints rehabilitated by ferrocement jackets [J].
Li, Bo ;
Lam, Eddie Siu-shu ;
Wu, Bo ;
Wang, Ya-yong .
ENGINEERING STRUCTURES, 2013, 56 :897-909