Determination of patient-specific internal gross tumor volumes for lung cancer using four-dimensional computed tomography

被引:82
作者
Ezhil, Muthuveni [1 ,2 ]
Vedam, Sastry [2 ]
Balter, Peter [2 ]
Choi, Bum [2 ]
Mirkovic, Dragan [2 ]
Starkschall, George [2 ]
Chang, Joe Y. [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
基金
美国国家卫生研究院;
关键词
TARGET VOLUME; RESPIRATORY MOTION; RADIATION-THERAPY; CT IMAGES; RADIOTHERAPY; SCANS; SIMULATION; 4D-CT; MIP;
D O I
10.1186/1748-717X-4-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: To determine the optimal approach to delineating patient-specific internal gross target volumes (IGTV) from four-dimensional (4-D) computed tomography (CT) image data sets used in the planning of radiation treatment for lung cancers. Methods: We analyzed 4D-CT image data sets of 27 consecutive patients with non-small-cell lung cancer (stage I: 17, stage III: 10). The IGTV, defined to be the envelope of respiratory motion of the gross tumor volume in each 4D-CT data set was delineated manually using four techniques: (1) combining the gross tumor volume (GTV) contours from ten respiratory phases (IGTV(AllPhases)); (2) combining the GTV contours from two extreme respiratory phases (0% and 50%) (IGTV(2Phases)); (3) defining the GTV contour using the maximum intensity projection (MIP) (IGTV(MIP)); and (4) defining the GTV contour using the MIP with modification based on visual verification of contours in individual respiratory phase (IGTV(MIP-Modified)). Using the IGTV(AllPhases) as the optimum IGTV, we compared volumes, matching indices, and extent of target missing using the IGTVs based on the other three approaches. Results: The IGTV(MIP) and IGTV(2Phases) were significantly smaller than the IGTV(AllPhases) (p < 0.006 for stage I and p < 0.002 for stage III). However, the values of the IGTV(MIP-Modified) were close to those determined from IGTV(AllPhases) (p = 0.08). IGTV(MIP-Modified) also matched the best with IGTV(AllPhases). Conclusion: IGTV(MIP) and IGTV(2Phases) underestimate IGTVs. IGTV(MIP-Modified) is recommended to improve IGTV delineation in lung cancer.
引用
收藏
页数:14
相关论文
共 18 条
[11]   Geometric accuracy of a real-time target tracking system with dynamic multileaf collimator tracking system [J].
Keall, Paul J. ;
Cattell, Herbert ;
Pokhrel, Damodar ;
Dieterich, Sonja ;
Wong, Kenneth H. ;
Murphy, Martin J. ;
Vedam, S. Sastry ;
Wijesooriya, Krishni ;
Mohan, Radhe .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (05) :1579-1584
[12]   Acquiring 4D thoracic CT scans using a multislice helical method [J].
Keall, PJ ;
Starkschall, G ;
Shukla, H ;
Forster, KM ;
Ortiz, V ;
Stevens, CW ;
Vedam, SS ;
George, R ;
Guerrero, T ;
Mohan, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (10) :2053-2067
[13]   Assessing respiration-induced tumor motion and internal target volume using four-dimensional computed tomography for radiotherapy of lung cancer [J].
Liu, H. Helen ;
Balter, Peter ;
Tutt, Teresa ;
Choi, Bum ;
Zhang, Joy ;
Wang, Catherine ;
Chi, Melinda ;
Luo, Dershan ;
Pan, Tinsu ;
Hunjan, Sandeep ;
Starkschall, George ;
Rosen, Isaac ;
Prado, Karl ;
Liao, Zhongxing ;
Chang, Joe ;
Komaki, Ritsuko ;
Cox, James D. ;
Mohan, Radhe ;
Dong, Lei .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (02) :531-540
[14]   4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT [J].
Pan, T ;
Lee, TY ;
Rietzel, E ;
Chen, GTY .
MEDICAL PHYSICS, 2004, 31 (02) :333-340
[15]  
REITZEL E, 2008, INT J RADIAT ONCOL, V71, P1245
[16]   Simulation of four-dimensional CT images from deformable registration between inhale and exhale breath-hold CT scans [J].
Sarrut, D ;
Boldea, V ;
Miguet, S ;
Ginestet, C .
MEDICAL PHYSICS, 2006, 33 (03) :605-617
[17]   Use of maximum intensity projections (MIP) for target volume generation in 4DCT scans for lung cancer [J].
Underberg, RWM ;
Lagerwaard, FJ ;
Slotman, BJ ;
Cuijpers, JP ;
Senan, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (01) :253-260
[18]   Acquiring a four-dimensional computed tomography dataset using an external respiratory signal [J].
Vedam, SS ;
Keall, PJ ;
Kini, VR ;
Mostafavi, H ;
Shukla, HP ;
Mohan, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (01) :45-62