An uncommon cause of cemented unicompartmental knee arthroplasty failure: fracture of metallic components

被引:10
作者
Manzotti, Alfonso [1 ]
Chemello, Cesare [2 ]
Pullen, Chris [3 ]
Cerveri, Pietro [4 ]
Confalonieri, Norberto [1 ]
机构
[1] CTO Hosp, Orthoped Dept 1, I-20100 Milan, Italy
[2] Azienda Osped Padova, Clin Ortoped, I-35123 Padua, Italy
[3] Royal Melbourne Hosp, Dept Orthopaed, Parkville, Vic 3050, Australia
[4] Politecn Milan, Bioengn Dept, I-20100 Milan, Italy
关键词
Unicompartmental Knee Arthroplasty; Metallic component breakage; FEMORAL COMPONENT; OXFORD KNEE; REPLACEMENT; REVISION; PROSTHESIS; THICKNESS; ALIGNMENT; WEAR;
D O I
10.1007/s00167-012-2062-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Despite good overall clinical results, unicompartmental knee replacements (UKR) are not without their problems and failures have been reported. The most common causes of UKR failure are component loosening, poor patient selection, poor surgical technique, polyethylene wear and progression of arthritis in other compartments. The purpose of this study is to present a series of atraumatic fractures of metallic components in a UKR treated in a single orthopaedic centre. Since 1999, 121 failed unicompartmental knee arthroplasties have been referred to our centre. In six of these, atraumatic breakage of a metal component in the cemented UKR was seen and included in this study. Pre-operative alignment, BMI and implant longevity were documented. The femoral implant failed in 4 patients and the tibial implant in a further 2. All the femoral implant fractures occurred within 3 years of UKR surgery (mean: 22.2 months, SD: 10.6 months). Tibial implant breakage occurred at a mean of 8.5 years (SD: 2.4 months) following UKR. All patients were treated with conversion to a navigated total knee replacement. A primary total knee arthroplasty was used in all cases with one patient requiring a tibial component incorporating a wedge and stem following breakage of the original UKR tibial implant. Fracture of the metallic components is a potential cause of failure of unicompartmental knee arthroplasty. In our experience, the incidence of this complication was 4.9 % of all UKR failures. Patients with a BMI greater than 30 and a progressive deterioration in limb alignment were at greater risk. IV.
引用
收藏
页码:2518 / 2522
页数:5
相关论文
共 26 条
  • [1] The unicompartmental knee - Design and technical considerations in minimizing wear
    Argenson, Jean-Noel A.
    Parratte, Sebastien
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (452) : 137 - 142
  • [2] POLYETHYLENE WEAR IN MENISCAL KNEE REPLACEMENT - A ONE TO 9-YEAR RETRIEVAL ANALYSIS OF THE OXFORD KNEE
    ARGENSON, JN
    OCONNOR, JJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (02): : 228 - 232
  • [3] Lateral unicompartmental knee replacement - Survivorship and clinical experience over 21
    Ashraf, T
    Newman, JH
    Evans, RL
    Ackroyd, CE
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (08): : 1126 - 1130
  • [4] Bellamy N, 2002, J RHEUMATOL, V29, P2473
  • [5] BUECHEL FF, 1989, CLIN ORTHOP RELAT R, P34
  • [6] Cameron H U, 1990, J Arthroplasty, V5, P315, DOI 10.1016/S0883-5403(08)80089-7
  • [7] Computer-assisted Revision of Failed Unicompartmental Knee Arthroplasty
    Confalonieri, Norberto
    Manzotti, Alfonso
    Chemello, Cesare
    Cerveri, Pietro
    [J]. ORTHOPEDICS, 2010, 33 (10) : 52 - 57
  • [8] Engh G A, 1999, Instr Course Lect, V48, P167
  • [9] Failure mechanisms after unicompartmental and tricompartmental primary knee replacement with cement
    Furnes, O.
    Espehaug, B.
    Lie, S. A.
    Vollset, S. E.
    Engesaeter, L. B.
    Havelin, L. I.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (03) : 519 - 525
  • [10] GOODFELLOW JW, 1986, CLIN ORTHOP RELAT R, P21