Electro-Fenton as a feasible advanced treatment process to produce reclaimed water

被引:25
作者
Moreno, AD
Frontana-Uribe, BA
Zamora, RMR
机构
[1] Univ Nacl Autonoma Mexico, Fac Quim, Mexico City 04510, DF, Mexico
[2] Univ Nacl Autonoma Mexico, Inst Quim, Mexico City 04510, DF, Mexico
[3] Univ Nacl Autonoma Mexico, Inst Ingn, Mexico City 04510, DF, Mexico
关键词
advanced oxidation; coagulation-flocculation; electro-Fenton; reclaimed water; wastewater treatment;
D O I
10.2166/wst.2004.0095
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The feasibility of the electro-Fenton process to generate simultaneously both of the Fenton's reagent species (Fe2+/H2O2), was assessed as a potentially more economical alternative to the classical Fenton's reaction to produce reclaimed water. An air-saturated combined wastewater (mixture of municipal and laboratory effluents) was treated in discontinuous and continuous reactors at pH = 3.5. The discontinuous reactor was a 2 L electrochemical laboratory cell fitted with concentric graphite and iron electrodes. The continuous reactor tests used a pilot treatment system comprising the aforementioned electrochemical cell, two clarifiers and one sand filter. Several tests were carried out at different conditions of reaction time (0-60 min) and electrical current values (0.2-1.0 A) in the discontinuous reactor. The best operating conditions were 60 min and 1 A without filtration of effluents. At these conditions, in discontinuous and continuous reactors with filtration, the COD, turbidity and color removal were 65-74.8%, 77-92.3 % and 80-100%, respectively. Fecal and total coliforms, Escherichia coli, Shigella and Salmonella sp. were not detected at the end of the pilot treatment system. Electrogeneration of the Fenton's reagent is also economical; its cost is one-fifth the cost reported for Advanced Primary Treatment.
引用
收藏
页码:83 / 90
页数:8
相关论文
共 13 条
[1]  
APHA/AWWA/WEF , 1998, STAND METH EX WAT WA
[2]   Mineralization of 2,4-D by advanced electrochemical oxidation processes [J].
Brillas, E ;
Calpe, JC ;
Casado, J .
WATER RESEARCH, 2000, 34 (08) :2253-2262
[3]  
Huang C. P., 1993, Waste Management, V13, P361, DOI 10.1016/0956-053X(93)90070-D
[4]  
JIMENEZ B, 1998, P WAT REUS C AWWA WE, P269
[5]  
Langlais B., 1991, Ozone in Water Treatment: Application and Engineering
[6]   Treatment of landfill leachate by combined electro-fenton oxidation and sequencing batch reactor method [J].
Lin, SH ;
Chang, CC .
WATER RESEARCH, 2000, 34 (17) :4243-4249
[7]   Fenton's reagent and coagulation-flocculation as pretreatments of combined wastewater for reuse [J].
Moreno, AD ;
Lorenzo, EG ;
De Bazúa, CD ;
De La Torre, JM ;
Zamora, RMR .
WATER SCIENCE AND TECHNOLOGY, 2003, 47 (11) :145-151
[8]  
Sawyer DT, 1997, COORDIN CHEM REV, V165, P297, DOI 10.1016/S0010-8545(97)00019-2
[9]  
United States Environment Protection Agency-USEPA, 1992, Technical Report N EPA/625/R-92/004
[10]  
VERASTEGUI YM, 2002, THESIS UNAM