Determination of Clenbuterol by Multiwalled Carbon Nanotube Potentiometric Sensors

被引:16
作者
Ozkutuk, Ebru Birlik [1 ]
Ugurag, Deniz [1 ]
Ersoz, Arzu [2 ]
Say, Ridvan [2 ]
机构
[1] Eskisehir Osmangazi Univ, Dept Chem, Eskisehir, Turkey
[2] Anadolu Univ, Dept Chem, Eskisehir, Turkey
关键词
beta-agonists; carbon paste electrode; clenbuterol; molecularly imprinted polymers; poly(vinyl chloride) membrane electrode; potentiometry; SOLID-PHASE EXTRACTION; MOLECULAR-IMPRINTED POLYMER; ION-SELECTIVE ELECTRODES; RESIDUAL CLENBUTEROL; LIGAND-EXCHANGE; PRECONCENTRATION; COEFFICIENTS; PROPRANOLOL;
D O I
10.1080/00032719.2015.1079213
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Potentimetric sensors based on molecularly imprinted polymers are reported for the selective determination of clenbuterol. The work involved the modification of multiwalled carbon nanotubes, the modification of chitosan with diethylene triamine pentaacetic acid, the synthesis of the clenbuterol-imprinted polymer, and the preparation of potentiometric sensors using the clenbuterol-imprinted polymer. The effect of pH, response time, lifetime, selectivity, reusability, reproducibility, accuracy, and stability of the sensors were characterized. The optimum pH was 6.0 for the prepared poly(vinyl chloride) membrane and carbon paste electrodes. The limit of detection of the poly(vinyl chloride) membrane electrode was 0.49x10(-8)mM, with the linear dynamic range from 1.0x10(-5) to 1.0x10(-9)mM. The response time for the membrane electrode was 2min and the operational lifetime was 23 weeks. For the carbon paste electrode, the limit of detection was 0.91x10(-8)mM, the linear dynamic range was from 1.0x10(-4) to 1.0x10(-9)mM, the response time was 1min, and the operational lifetime was 24 weeks.
引用
收藏
页码:778 / 789
页数:12
相关论文
共 50 条
[1]   A highly selective solid phase extraction sorbent for pre-concentration of sameridine made by molecular imprinting [J].
Andersson, LI ;
Paprica, A ;
Arvidsson, T .
CHROMATOGRAPHIA, 1997, 46 (1-2) :57-62
[2]   A solid binding matrix/molecularly imprinted polymer-based sensor system for the determination of clenbuterol in bovine liver using differential-pulse voltammetry [J].
Andrea, P ;
Miroslav, S ;
Silvia, S ;
Stanislav, M .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 76 (1-3) :286-294
[3]  
[Anonymous], 2006, AM SCI PUBLISHER
[4]   Modern Potentiometry [J].
Bakker, Eric ;
Pretsch, Ernoe .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2007, 46 (30) :5660-5668
[5]   Double-imprinted potentiometric sensors based on ligand exchange for the determination of dimethoate [J].
Bektasoglu, Eyup ;
Ozkutuk, Ebru Birlik ;
Ersoz, Arzu ;
Say, Ridvan .
KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2015, 32 (08) :1613-1617
[6]   Development of New Molecular Imprinted Solid Phase Extraction Material for Dimethoate [J].
Bektasoglu, Eyup ;
Ozkutuk, Ebru Birlik ;
Ersoz, Arzu ;
Say, Ridvan .
SPECTROSCOPY LETTERS, 2014, 47 (03) :168-176
[7]   Preconcentration of copper using double-imprinted polymer via solid phase extraction [J].
Birlik, E ;
Ersöz, A ;
Denizli, A ;
Say, R .
ANALYTICA CHIMICA ACTA, 2006, 565 (02) :145-151
[8]   Selective separation of thorium using ion imprinted chitosan-phthalate particles via solid phase extraction [J].
Birlik, Ebru ;
Buyuktiryaki, Sibel ;
Ersoz, Arzu ;
Denizli, Adil ;
Say, Ridvan .
SEPARATION SCIENCE AND TECHNOLOGY, 2006, 41 (14) :3109-3121
[9]   4-Nitrophenol surface molecularly imprinted polymers based on multiwalled carbon nanotubes for the elimination of paraoxon pollution [J].
Chi, Wenhao ;
Shi, Heguang ;
Shi, Wang ;
Guo, Yong ;
Guo, Tianying .
JOURNAL OF HAZARDOUS MATERIALS, 2012, 227 :243-249
[10]   Trace determination of molybdenum by anodic adsorptive stripping voltammetry using a multi-walled carbon nanotubes modified carbon paste electrode [J].
Deng, Pei-Hong ;
Fei, Jun-Jie ;
Feng, Yong-Lan .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 148 (01) :214-220