Plasminogen Activator Inhibitor 1 (PAI-1) and Haematologic Parameters in HIV- Positive Patients on Protease Inhibitor-Based HAART Regimen: A Case-Control Study

被引:0
|
作者
Christopher, Chimeziem [1 ]
Nwogoh, Benedict [2 ]
Akaba, Kingsley [3 ]
Igwilo, Hilary [1 ]
Abang, Roger [4 ]
机构
[1] Univ Calabar, Dept Haematol, Calabar, Nigeria
[2] Univ Benin Teaching Hosp, Dept Haematol, Benin, Nigeria
[3] Univ Calabar, Haematol & Blood Transfus, Calabar, Nigeria
[4] Fed Neuropsychiat Hosp Calabar, Dept Psychiat, Calabar, Nigeria
关键词
thrombosis; human immunodeficiency virus; plasminogen activator inhibitor 1; ANTIRETROVIRAL THERAPY; THROMBOSIS; INFECTION; DEPLETION; MARKERS; RISK; ERA;
D O I
10.1177/10760296221126176
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Human immunodeficiency virus (HIV) infection is associated with an increased risk of hypercoagulability and treatment with antiretroviral agents especially protease inhibitors has also been reported to contribute to this risk. Altered fibrinolytic activity is reported as a mechanism of increased thrombotic risk in HIV patients on therapy. However, this has not been investigated in our environment. Objective: To evaluate and compare PAI-1 levels as a marker of thrombotic risk in HIV-infected persons on PI-based HAART regimen with those on non-PI-based therapy and to correlate PAI-1 with haematological parameters. Methods: This was a comparative cross-sectional study conducted at the University of Calabar Teaching Hospital (UCTH), Calabar, Cross River State. A total of 125 subjects including 45 HIV-positive patients on PI-based HAART regimen, 42 HIV-positive patients on non-PI-based HAART regimen and 38 Controls. The controls include 18 HIV-positive therapy naive patients and 20 HIV-negative controls. PAI 1 and blood counts were estimated using standard methods. Data were analyzed using the IBM version of the statistical package for social sciences (SPSS) version 22. Statistical significance was set at 0.05. Result: The median PAI-1 level was significantly increased in patients on PI-based HAART regimen (p = 0.004). The blood counts did not differ significantly between patients on PI and non-PI-based HAART regimens (p > 0.05). There were no significant correlations between PAI-1 levels and blood counts (p > 0.05). Conclusion: PAI-1 level is elevated in HIV patients on PI-based HAART regimen. However, the association with thrombotic events could not be established in the study.
引用
收藏
页数:10
相关论文
共 31 条
  • [31] Frequency of factor II G20210A, factor V Leiden, MTHFR C677T and PAI-1 5G/4G polymorphism in patients with venous thromboembolism: Croatian case-control study
    Alfirevic, Zrinka
    Simundic, Ana-Maria
    Nikolac, Nora
    Sobocan, Nikola
    Alfirevic, Igor
    Stefanovic, Mario
    Vucicevic, Zeljko
    Topic, Elizabeta
    BIOCHEMIA MEDICA, 2010, 20 (02) : 229 - 235