Performance of a new signal processing system for a detector array

被引:0
|
作者
Kimura, Atsushi [1 ]
Koizumi, Mitsuo [1 ]
Toh, Yosuke [1 ]
Osa, Akihiko [1 ]
Oshima, Masumi [1 ]
Arai, Yasuo [1 ]
Sagara, Masahiro [1 ]
Iri, Shinichi [1 ]
Kobayashi, Hirotsugu [1 ]
Maeda, Daisuke [1 ]
Hirayama, Tadashi [1 ]
Suzuki, Yasuhiro [1 ]
机构
[1] Japan Atom Energy Agcy, Res Grp Innovat Nucl Sci, Tokai, Ibaraki, Japan
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
To measure neutron cross-section data of minor actinides, we construct a 4-pi Ge-spectrometer utilizing multiple gamma-ray detection method. This spectrometer consists of 30 Ge crystals (40 detector outputs) and 128 BGO anti-Compton shields. Generally, a data acquisition system for such a big Ge spectrometer consists of many NIM modules; it requires large space and huge cost. To overcome these problems, we developed a new data acquisition system with digital signal processing techniques. This system is mounted in a 19 inches VME sub-rack, and the cost of this system is greatly reduced. Obtained FWHMs (2.5 similar to 2.8 keV at 1.33 MeV) show good performances as normal MCA even with short shaping time and much higher channel density. The dead time of this system is only 3.2 micro sec per event. Thus good energy resolution is achieved with short shaping time and short dead time.
引用
收藏
页码:570 / 574
页数:5
相关论文
共 50 条
  • [1] SIGNAL-PROCESSING FOR AN INFRARED ARRAY DETECTOR
    YOUNG, MA
    SMITH, GE
    PIMENTEL, GC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (09): : 2920 - 2923
  • [2] ON PERFORMANCE OF ARRAY SIGNAL PROCESSING.
    Nolte, Loren W.
    Lee, Sang C.
    Liu, Sien-Chang C.
    1600, (OE-12):
  • [3] ON PERFORMANCE OF ARRAY SIGNAL-PROCESSING
    NOLTE, LW
    LEE, SC
    LIU, SCC
    IEEE JOURNAL OF OCEANIC ENGINEERING, 1987, 12 (01) : 148 - 154
  • [4] The new architecture for high performance signal processing system
    He, B
    Wang, XN
    2004 7TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING PROCEEDINGS, VOLS 1-3, 2004, : 511 - 514
  • [5] GAMMASPHERE - Overview of detector and signal processing system
    Goulding, FS
    Landis, DA
    Madden, N
    Maier, M
    Yaver, H
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 432 - 436
  • [6] SIGNAL PROCESSING SYSTEM FOR A SEMICONDUCTOR DETECTOR LADDER
    WHITTAKER, JK
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1972, NS19 (03) : 444 - +
  • [7] A FPGA-based Signal Processing Unit for a GEM Array Detector
    Yen, W. W.
    Chou, H. P.
    2013 3RD INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION, MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2013,
  • [8] A New Design of Signal Processing System for TDI Infrared Focal Plane Array
    Wang, Hua
    Wei, Zhiyong
    Lei, Ning
    Wang, Xu
    Zhang, Wenyu
    Li, Tao
    INFRARED, MILLIMETER-WAVE, AND TERAHERTZ TECHNOLOGIES II, 2012, 8562
  • [10] Performance bounds for subspace estimation in array signal processing
    Srivastava, A
    NINTH IEEE SIGNAL PROCESSING WORKSHOP ON STATISTICAL SIGNAL AND ARRAY PROCESSING, PROCEEDINGS, 1998, : 140 - 143