Off-pump transapical mitral valve replacement

被引:26
作者
Lutter, Georg [1 ]
Quaden, Rene [1 ]
Osaki, Satoru [2 ]
Hu, Jian [2 ]
Renner, Jochen [2 ]
Edwards, Niloo M. [3 ]
Cremer, Jochen [1 ]
Lozonschi, Lucian [3 ]
机构
[1] Univ Hosp Schleswig Holstein, Dept Cardiovasc Surg, Kiel, Germany
[2] Univ Hosp Schleswig Holstein, Dept Anaesthesia, Kiel, Germany
[3] Univ Wisconsin, Sch Med & Publ Hlth, Dept Cardiovasc Surg, Madison, WI USA
关键词
Valve replacement; Mitral; Off-pump; Catheter; Transapical; Transcatheter; Percutaneous; Minimally invasive; Valved stent; STENT;
D O I
10.1016/j.ejcts.2009.02.037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Percutaneous valve replacement was recently introduced, and reports of early clinical experience have already been published. To date, this technique is limited to the replacement of pulmonary and aortic valves in a strictly selected group of patients. The aim of this study was to analyse a self-expanding valved stent for minimally invasive replacement of the mitral valve in animals. Methods: A newly designed nitinol stent was specially designed for this experimental acute study. It comprised of a left ventricular tubular stent with star shaped left atrial anchoring springs and carried a trileaflet bovine pericardial valve. A polytetrafluoroethylene membrane was sutured to envelop the atrial springs and the outside of the ventricular stent. The ventricular anchoring system was the same as in our previously reported results with a similar mitral valved stent. Seven pigs underwent minimally invasive off-pump mitral valved stent implantation. This was per-formed through a tower ministernotomy and a standard transapical approach under transoesophageal echocardiographic (TEE) guidance was used. Results: The valved stent is fully retrievable and precise deployment and accurate adjustment of its intra-annular position is achievable to eliminate paravalvular leakage. The deployment time ranged from 127 to 255 s and the blood loss from 70 to 220 cc. One animal died of intractable ventricular fibrillation. Mitral regurgitation in all surviving animals was minimal (trace in 5/6 and mild in 1/6 during echo examination; on the contrast ventriculogram no mitral insufficiency was observed except in one documented as mild paravalvular regurgitation). These animals remained haemodynamically stable (6/6) and without TEE or ventriculographic changes for 1 h. Conclusion: Implantation of a tricuspid bovine pericardial valved stent in the mitral position is feasible in pigs through a transcatheter approach. This was possible through a smaller delivery system than previously reported. Additional studies are required to demonstrate long-term feasibility, durability, and heart function. (C) 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. Ail rights reserved.
引用
收藏
页码:124 / 128
页数:5
相关论文
共 5 条
[1]   Percutaneous valve replacement: a novel low-profile polyurethane valved stent [J].
Attmann, Tim ;
Steinseifer, Ulrich ;
Cremer, Jochen ;
Lutter, Georg .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2006, 30 (02) :379-379
[2]   Steps toward the percutaneous replacement of atrioventricular valves - An experimental study [J].
Boudjemline, Y ;
Agnoletti, G ;
Bonnet, D ;
Behr, L ;
Borenstein, N ;
Sidi, D ;
Bonhoeffer, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (02) :360-365
[3]   Transapical mitral valved stent implantation [J].
Lozonschi, Lucian ;
Quaden, Rene ;
Edwards, Niloo M. ;
Cremer, Jochen ;
Lutter, Georg .
ANNALS OF THORACIC SURGERY, 2008, 86 (03) :745-748
[4]   Transmyocardial laser revascularization: Experimental studies in healthy porcine myocardium [J].
Lutter, G ;
Martin, J ;
Takahashi, N ;
Yoshitake, M ;
Schwarzkopf, J ;
Nitzsche, E ;
Beyersdorf, F .
ANNALS OF THORACIC SURGERY, 1999, 67 (06) :1708-1713
[5]   Double-crowned valved stents for off-pump mitral valve replacement [J].
Ma, L ;
Tozzi, P ;
Huber, CH ;
Taub, S ;
Gerelle, G ;
von Segesser, LK .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 28 (02) :194-198