Optimization of Image Reconstruction for 90Y Selective Internal Radiotherapy on a Lutetium Yttrium Orthosilicate PET/CT System Using a Bayesian Penalized Likelihood Reconstruction Algorithm

被引:29
作者
Rowley, Lisa M. [1 ]
Bradley, Kevin M. [2 ]
Boardman, Philip [2 ]
Hallam, Aida [1 ]
McGowan, Daniel R. [1 ,3 ]
机构
[1] Oxford Univ Hosp NHS Fdn Trust, Churchill Hosp, Radiat Phys & Protect, Oxford, England
[2] Oxford Univ Hosp NHS Fdn Trust, Churchill Hosp, Dept Radiol, Oxford, England
[3] Univ Oxford, Dept Oncol, Oxford, England
关键词
positron emission tomography; Bayesian penalized likelihood; Q.Clear; image reconstruction; RADIOEMBOLIZATION; DOSIMETRY;
D O I
10.2967/jnumed.116.176552
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Imaging on a gamma-camera with Y-90 after selective internal radiotherapy (SIRT) may allow for verification of treatment delivery but suffers relatively poor spatial resolution and imprecise dosimetry calculation. 90Y PET/CT imaging is possible on 3-dimensional, time-of-flight machines; however, images are usually poor because of low count statistics and noise. A new PET reconstruction software using a Bayesian penalized likelihood (BPL) reconstruction algorithm (termed Q.Clear) was investigated using phantom and patient scans to optimize the reconstruction for post-SIRT imaging and clarify whether BPL leads to an improvement in clinical image quality using 90Y. Methods: Phantom studies over an activity range of 0.5-4.2 GBq were performed to assess the contrast recovery, background variability, and contrast-to-noise ratio for a range of BPL and ordered-subset expectation maximization (OSEM) reconstructions on a PET/CT scanner. Patient images after SIRT were reconstructed using the same parameters and were scored and ranked on the basis of image quality, as assessed by visual evaluation, with the corresponding SPECT/CT Bremsstrahlung images by 2 experienced radiologists. Results: Contrast-to noise ratio was significantly better in BPL reconstructions when compared with OSEM in phantom studies. The patient-derived BPL and matching Bremsstrahlung images scored higher than OSEM reconstructions when scored by radiologists. BPL with a beta value of 4,000 was ranked the highest of all images. Deadtime was apparent in the system above a total phantom activity of 3.3 GBq. Conclusion: BPL with a 13 value of 4,000 is the optimal image reconstruction in PET/CT for confident radiologic reading when compared with other reconstruction parameters for 90Y imaging after SIRT imaging. Activity in the field of view should be below 3.3 GBq at the time of PET imaging to avoid deadtime losses for this scanner.
引用
收藏
页码:658 / 664
页数:7
相关论文
共 23 条
[11]   Post-radioembolization yttrium-90 PET/CT - part 1: diagnostic reporting [J].
Kao, Yung-Hsiang ;
Steinberg, Jeffrey D. ;
Tay, Young-Soon ;
Lim, Gabriel K. Y. ;
Yan, Jianhua ;
Townsend, David W. ;
Takano, Angela ;
Burgmans, Mark C. ;
Irani, Farah G. ;
Teo, Terence K. B. ;
Yeow, Tow-Non ;
Gogna, Apoorva ;
Lo, Richard H. G. ;
Tay, Kiang-Hiong ;
Tan, Bien-Soo ;
Chow, Pierce K. H. ;
Satchithanantham, Somanesan ;
Tan, Andrew E. H. ;
Ng, David C. E. ;
Goh, Anthony S. W. .
EJNMMI RESEARCH, 2013, 3 :1-28
[12]   Feasibility of 90Y TOF PET-based dosimetry in liver metastasis therapy using SIR-Spheres [J].
Lhommel, Renaud ;
van Elmbt, Larry ;
Goffette, Pierre ;
Van den Eynde, Marc ;
Jamar, Francois ;
Pauwels, Stanislas ;
Walrand, Stephan .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (09) :1654-1662
[13]   PET optimization for improved assessment and accurate quantification of 90Y-microsphere biodistribution after radioembolization [J].
Marti-Climent, Josep M. ;
Prieto, Elena ;
Elosua, Cesar ;
Rodriguez-Fraile, Macarena ;
Dominguez-Prado, Ines ;
Vigil, Carmen ;
Garcia-Velloso, Maria J. ;
Arbizu, Javier ;
Penuelas, Ivan ;
Richter, Jose A. .
MEDICAL PHYSICS, 2014, 41 (09)
[14]  
National Electrical Manufacturers Association (NEMA), 2007, NEMA STAND PUBL
[15]   Does a novel penalized likelihood reconstruction of 18F-FDG PET-CT improve signal-to-background in colorectal liver metastases? [J].
Parvizi, Nassim ;
Franklin, James M. ;
McGowan, Daniel R. ;
Teoh, Eugene J. ;
Bradley, Kevin M. ;
Gleeson, Fergus V. .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (10) :1873-1878
[16]   Radioembolization and the dynamic role of Y-90 PET/CT [J].
Pasciak, Alexander S. ;
Bourgeois, Austin C. ;
McKinney, J. Mark ;
Chang, Ted T. ;
Osborne, Dustin R. ;
Acuff, Shelley N. ;
Bradley, Yong C. .
FRONTIERS IN ONCOLOGY, 2014, 4
[17]  
Ross S. Q., 2013, CLEAR WHITE PAPER
[18]   The Impact of Image Reconstruction Bias on PET/CT 90Y Dosimetry After Radioembolization [J].
Tapp, Katie N. ;
Lea, William B. ;
Johnson, Matthew S. ;
Tann, Mark ;
Fletcher, James W. ;
Hutchins, Gary D. .
JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (09) :1452-1458
[19]   18F-FDG PET/CT assessment of histopathologically confirmed mediastinal lymph nodes in non-small cell lung cancer using a penalised likelihood reconstruction [J].
Teoh, Eugene J. ;
McGowan, Daniel R. ;
Bradley, Kevin M. ;
Belcher, Elizabeth ;
Black, Edward ;
Moore, Alastair ;
Sykes, Annemarie ;
Gleeson, Fergus V. .
EUROPEAN RADIOLOGY, 2016, 26 (11) :4098-4106
[20]   Novel penalised likelihood reconstruction of PET in the assessment of histologically verified small pulmonary nodules [J].
Teoh, Eugene J. ;
McGowan, Daniel R. ;
Bradley, Kevin M. ;
Belcher, Elizabeth ;
Black, Edward ;
Gleeson, Fergus V. .
EUROPEAN RADIOLOGY, 2016, 26 (02) :576-584