Clinical Validation and Comparison of Alternative Methods for Evaluation of Entrainment Mapping

被引:5
作者
Derejko, Pawel [1 ]
Szumowski, Lukasz J. [1 ]
Sanders, Prashanthan [2 ,3 ,4 ]
Dimitri, Hany [2 ,3 ,4 ]
Kuklik, Pawel [2 ,3 ,4 ]
Przybylski, Andrzej [1 ]
Urbanek, Piotr [1 ]
Szufladowicz, Ewa [1 ]
Bodalski, Robert [1 ]
Sacher, Frederic [5 ,6 ]
Haissaguerre, Michel [5 ,6 ]
Walczak, Franciszek [1 ]
机构
[1] Inst Cardiol, PL-04628 Warsaw, Poland
[2] Royal Adelaide Hosp, Cardiovasc Res Ctr, Dept Cardiol, Adelaide, SA 5000, Australia
[3] Univ Adelaide, Discipline Med, Adelaide, SA, Australia
[4] Univ Adelaide, Discipline Physiol, Adelaide, SA, Australia
[5] Hop Cardiol Haut Leveque, Bordeaux, France
[6] Univ Bordeaux 2, F-33076 Bordeaux, France
关键词
entrainment mapping; RF ablation; atrial tachycardia; ventricular tachycardia; atrial flutter; reentry; VENTRICULAR-TACHYCARDIA; CRITICAL ISTHMUS; ATRIAL-FLUTTER; REMOTE SITES; IDENTIFICATION; ELECTROGRAMS; ABLATION;
D O I
10.1111/j.1540-8167.2008.01425.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Measuring the postpacing interval (PPI) and correcting for the tachycardia cycle length (TCL) is an important entrainment response (ER). However, it may be impossible to measure PPI due to electrical noise on the mapping catheter. To overcome this problem, 2 alternative methods for the assessment of ER have been proposed: N+1 difference (N+1 DIFF) and PPIR method. PPI-TCL difference (PPI - TCL) correlates very well with ER assessed by new methods, but the agreement with PPI - TCL was established only in relation to PPIR method. Moreover, it is not known which of these methods is superior in the assessment of ER. Methods: We analyzed 155 episodes of ER in 21 patients with heterogeneous reentrant arrhythmias. ER was estimated by PPI - TCL and by both alternative methods. Agreement between methods was assessed by means of the Bland-Altman test, kappa coefficient (kappa), and correlation coefficient (r). Finally, a mathematical comparison of the alternative methods was performed. Results: The agreement between PPI - TCL and alternative methods was very good. For N+1 DIFF the mean difference was -1.86 +/- 7.31 ms; kappa = 0.9; r = 0.98; for PPIR method the mean difference was -1.46 +/- 7.65 ms; kapa = 0.92; r = 0.99. Agreement between both alternative methods was also very high: the mean difference of 0.5 +/- 6.6 ms; kappa = 0.89; r = 0.99. The analysis of the equations used for calculation of ER by these methods revealed that essentially they were mathematically equivalent. Conclusion: Each of the alternative methods may be used for evaluation of ER when PPI - TCL cannot be assessed directly. Results obtained by both alternative methods are comparable. (J Cardiovasc Electrophysiol, Vol. 20, pp. 741-748, July 2009).
引用
收藏
页码:741 / 748
页数:8
相关论文
共 16 条
[1]  
Altman DG, 1992, PRACTICAL STAT MED R, P396
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Using Electrocardiographic activation time and diastolic intervals to separate focal from macro-re-entrant atrial tachycardias [J].
Brown, Jason P. ;
Krummen, David E. ;
Feld, Gregory K. ;
Narayan, Sanjiv M. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (19) :1965-1973
[4]   Value of entrainment mapping in determining the isthmus-dependent nature of atrial flutter in the presence of amiodarone [J].
Fatemi, M ;
Mansourati, J ;
Rosu, R ;
Blanc, JJ .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (12) :1409-1415
[5]  
FONTAINE G, 1989, PACE, V12, P62
[6]   Effect of recording site on postpacing interval measurement during catheter mapping and entrainment of postinfarction ventricular tachycardia [J].
Hadjis, TA ;
Harada, T ;
Stevenson, WG ;
Friedman, PL .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1997, 8 (04) :398-404
[7]   Estimation of entrainment response using electrograms from remote sites: Validation in animal and computer models of reentrant tachycardia [J].
Hammer, PE ;
Brooks, DH ;
Triedman, JK .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (01) :52-61
[8]   An approach to noncavotricuspid isthmus dependent flutter [J].
Jaïs, P ;
Hocini, M ;
Sanders, P ;
Hsu, LF ;
Rotter, M ;
Sacher, F ;
Takahashi, Y ;
Rostock, T ;
Le Metayer, P ;
Clémenty, J ;
Haïssaguerre, M .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (06) :666-673
[9]   Ablation of 'incisional' reentrant atrial tachycardia complicating surgery for congenital heart disease - Use of entrainment to define a critical isthmus of conduction [J].
Kalman, JM ;
VanHare, GF ;
Olgin, JE ;
Saxon, LA ;
Stark, SI ;
Lesh, MD .
CIRCULATION, 1996, 93 (03) :502-512
[10]   Sensitivity and specificity of concealed entrainment for the identification of a critical isthmus in the atrium: Relationship to rate, anatomic location and antidromic penetration [J].
Morton, JB ;
Sanders, P ;
Deen, V ;
Vohra, JK ;
Kalman, JM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) :896-906