Dosimetry of dose distributions in radiotherapy of patients with surgical implants

被引:6
作者
Brozyna, Boguslaw [1 ,2 ]
Chelminski, Krzysztof [2 ,3 ]
Bulski, Wojciech [2 ,3 ]
Gizynska, Marta [2 ,3 ]
Grochowska, Paulina [4 ]
Walewska, Agnieszka [2 ,3 ]
Zalewska, Marta [2 ,3 ]
Kawecki, Andrzej [1 ,2 ]
Krajewski, Romuald [1 ,2 ]
机构
[1] Maria Sklodowska Curie Mem Canc Ctr, Dept Head & Neck Canc, PL-02781 Warsaw, Poland
[2] Inst Oncol, PL-02781 Warsaw, Poland
[3] Maria Sklodowska Curie Mem Canc Ctr, Dept Med Phys, PL-02781 Warsaw, Poland
[4] IAEA, Div Human Hlth, A-1400 Vienna, Austria
关键词
Gafchromic EBT; Titanium implants; Resorbable implants; Radiotherapy; RADIOCHROMIC FILM DOSIMETRY; ATOMIC-NUMBER INTERFACES; RADIATION-THERAPY; X-RAY; PERTURBATION; PLATES; OSTEORADIONECROSIS; SPECTRA;
D O I
10.1016/j.radphyschem.2014.03.008
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The investigation was performed in order to evaluate the use of Gafchromic EBT films for measurements of dose distributions created during radiotherapy in tissues surrounding titanium or resorbable implants used for joining and consolidating facial bones. Inhomogeneous dose distributions at implant-tissue interfaces can be the reason of normal tissue complications observed in radiotherapy patients after surgery with implants. The dose measured at a depth of 2.5 cm on contact surfaces, proximal and distal to the beam source, between the titanium implant and the phantom material was 109% and 92% respectively of the reference dose measured in a homogeneous phantom. For the resorbable implants the doses measured on the proximal and the distal contact surfaces were 102% and 101% respectively of the reference dose. The resorbable implants affect the homogeneity of dose distribution at a significantly lesser degree than the titanium implants. Gafchromic EBT films allowed for precise dose distribution measurements at the contact surfaces between tissue equivalent materials and implants. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:170 / 174
页数:5
相关论文
共 30 条
  • [1] Dose variation at bone/titanium interfaces using titanium hollow screw osseointegrating reconstruction plates
    Allal, AS
    Richter, M
    Russo, M
    Rouzaud, M
    Dulguerov, P
    Kurtz, JM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (01): : 215 - 219
  • [2] Absorption spectra variations of EBT radiochromic film from radiation exposure
    Butson, MJ
    Cheung, T
    Yu, PKN
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (13) : N135 - N140
  • [3] Energy dependence of radiochromic dosimetry films for use in radiotherapy verification
    Chelminski, Krzysztof
    Bulski, Wojciech
    Georg, Dietmar
    Bodzak, Dominika
    Maniakowski, Zbigniew
    Oborska, Dominika
    Rostkowska, Joanna
    Kania, Malgorzata
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2010, 15 (02) : 40 - 46
  • [4] Post-irradiation colouration of Gafchromic EBT radiochromic film
    Cheung, T
    Butson, MJ
    Yu, PKN
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (20) : N281 - N285
  • [5] VALIDITY OF TRANSITION-ZONE DOSIMETRY AT HIGH ATOMIC-NUMBER INTERFACES IN MEGAVOLTAGE PHOTON BEAMS
    DAS, IJ
    KASE, KR
    MEIGOONI, AS
    KHAN, FM
    WERNER, BL
    [J]. MEDICAL PHYSICS, 1990, 17 (01) : 10 - 16
  • [6] BACKSCATTER DOSE PERTURBATION AT HIGH ATOMIC-NUMBER INTERFACES IN MEGAVOLTAGE PHOTON BEAMS
    DAS, IJ
    KAHN, FM
    [J]. MEDICAL PHYSICS, 1989, 16 (03) : 367 - 375
  • [7] Effect of mandibular titanium reconstructive plates on radiation dose
    de Mello, FV
    Auader, M
    Cano, E
    Carrau, RL
    Myers, EN
    Miles, CE
    [J]. AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2003, 24 (04) : 231 - 235
  • [8] Precise radiochromic film dosimetry using a flat-bed document scanner
    Devic, S
    Seuntjens, J
    Sham, E
    Podgorsak, EB
    Schmidtlein, CR
    Kirov, AS
    Soares, CG
    [J]. MEDICAL PHYSICS, 2005, 32 (07) : 2245 - 2253
  • [9] EICHHORN M, 1988, STRAHLENTHER ONKOL, V164, P141
  • [10] Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance
    Fuss, Martina
    Sturtewagen, Eva
    De Wagter, Carlos
    Georg, Dietmar
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (14) : 4211 - 4225