Effects of different technical coordinate system definitions on the three dimensional representation of the glenohumeral joint centre

被引:33
作者
Campbell, Amity Cree [1 ]
Alderson, J. A. [1 ]
Lloyd, D. G. [1 ]
Elliott, B. C. [1 ]
机构
[1] Univ Western Australia, Sch Sport Sci Exercise & Hlth, Crawley, WA 6009, Australia
关键词
Shoulder joint centre; Motion analysis error; MRI; Data validity; SOFT-TISSUE ARTIFACT; ORIENTATION IN-SPACE; KNEE KINEMATICS; ROTATION CENTER; MOTION ANALYSIS; MOVEMENT; STEREOPHOTOGRAMMETRY; PERFORMANCE; VALIDATION; SHOULDER;
D O I
10.1007/s11517-009-0467-7
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This study aimed to find the most appropriate marker location, or combination thereof, for the centre of the humeral head (Wang et al. in J Biomech 31: 899-908, 1998) location representation during humeral motion. Ten male participants underwent three MRI scans in three different humeral postures. Seven technical coordinate systems (TCS) were defined from various combinations of an acromion, distal upper arm and proximal upper arm clusters of markers in a custom Matlab program. The CHH location was transformed between postures and then compared with the original MRI CHH location. The results demonstrated that following the performance of two near 180A degrees humeral elevations, a combined acromion TCS and proximal upper arm TCS produced an average error of 23 +/- A 9 mm, and 18 +/- A 4 mm, which was significantly smaller (p < 0.01) than any other TCS. A combination of acromion and proximal upper arm TCSs should therefore be used to reference the CHH location when analysing movements incorporating large ranges of shoulder motion.
引用
收藏
页码:543 / 550
页数:8
相关论文
共 23 条
  • [1] Correcting for deformation in skin-based marker systems
    Alexander, EJ
    Andriacchi, TP
    [J]. JOURNAL OF BIOMECHANICS, 2001, 34 (03) : 355 - 361
  • [2] A Point Cluster Method for In Vivo Motion Analysis: Applied to a Study of Knee Kinematics
    Andriacchi, TP
    Alexander, EJ
    Toney, MK
    Dyrby, C
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (06): : 743 - 749
  • [3] Soft tissue artifact compensation in knee kinematics by double anatomical landmark calibration: Performance of a novel method during selected motor tasks
    Cappello, A
    Stagni, R
    Fantozzi, S
    Leardini, A
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (06) : 992 - 998
  • [4] Surface-marker cluster design criteria for 3-D bone movement reconstruction
    Cappozzo, A
    Cappello, A
    DellaCroce, U
    Pensalfini, F
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (12) : 1165 - 1174
  • [5] POSITION AND ORIENTATION IN-SPACE OF BONES DURING MOVEMENT - ANATOMICAL FRAME DEFINITION AND DETERMINATION
    CAPPOZZO, A
    CATANI, F
    DELLA CROCE, U
    LEARDINI, A
    [J]. CLINICAL BIOMECHANICS, 1995, 10 (04) : 171 - 178
  • [6] Position and orientation in space of bones during movement: Experimental artefacts
    Cappozzo, A
    Catani, F
    Leardini, A
    Benedetti, MG
    DellaCroce, U
    [J]. CLINICAL BIOMECHANICS, 1996, 11 (02) : 90 - 100
  • [7] Kinematical models to reduce the effect of skin artifacts on marker-based human motion estimation
    Cerveri, P
    Pedotti, A
    Ferrigno, G
    [J]. JOURNAL OF BIOMECHANICS, 2005, 38 (11) : 2228 - 2236
  • [8] In vivo validation of a new technique that compensates for soft tissue artefact in the upper-arm: Preliminary results
    Cutti, AG
    Cappello, A
    Davalli, A
    [J]. CLINICAL BIOMECHANICS, 2006, 21 : S13 - S19
  • [9] Della Croce U., 1997, GAIT POSTURE, V5, P156, DOI DOI 10.1016/S0966-6362(97)83382-6
  • [10] Glenohumeral translation during active and passive elevation of the shoulder - a 3D open-MRI study
    Graichen, H
    Stammberger, T
    Bonel, H
    Englmeier, KH
    Reiser, M
    Eckstein, F
    [J]. JOURNAL OF BIOMECHANICS, 2000, 33 (05) : 609 - 613