Evaluation of Corneal Deformation Parameters Provided by the Corvis ST Tonometer After Trabeculectomy

被引:8
作者
Zong, Yuan [1 ,2 ,3 ]
Wu, Na [1 ,2 ,3 ]
Fu, Zhixuan [1 ,2 ,3 ]
Kong, Xiangmei [1 ,2 ,3 ]
机构
[1] Fudan Univ, Shanghai Med Coll, Eye Ear Nose & Throat Hosp, Dept Ophthalmol & Visual Sci, 83 Fenyang Rd, Shanghai 200031, Peoples R China
[2] Fudan Univ, Key Lab Myopia, Minist Hlth, Shanghai, Peoples R China
[3] Fudan Univ, Shanghai Key Lab Visual Impairment & Restorat, Shanghai, Peoples R China
关键词
intraocular pressure; Goldmann applanation tonometer; Corvis ST tonometer; corneal deformation parameters; glaucoma filtration surgery; OCULAR RESPONSE ANALYZER; OPEN-ANGLE GLAUCOMA; INTRAOCULAR-PRESSURE; BIOMECHANICAL PROPERTIES; AXIAL LENGTH; THICKNESS; HYSTERESIS; REDUCTION; NONCONTACT; AGE;
D O I
10.1097/IJG.0000000000000590
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aims of this study were to evaluate how the corneal deformation parameters provided by the Corvis ST tonometer (CST) were influenced by pressure-lowering ocular surgery, and to determine the correlations of intraocular pressure (IOP) and axial length (AL) with CST corneal deformation parameters. Methods: This prospective 1-month study enrolled 22 subjects (22 eyes) who underwent trabeculectomy combined with mitomycin C. The corneal deformation parameters were measured using the CST. IOP was measured before and after surgery by a Goldmann applanation tonometer and the CST. The central corneal thickness and AL were also recorded. The correlations of the corneal deformation parameters with central corneal thickness, AL, and IOP changes were determined by linear regression analysis. Results: IOP decreased significantly after surgery. AL was significantly shorter at 1 week after surgery. There were significant changes in the CST parameters time 1, velocity 1, velocity 2, peak distance highest concavity, and deformation amplitude highest concavity at 1 week and 1 month after surgery and in time highest concavity at 1 week after surgery. The change in time 1 was significantly correlated with pre-operative IOP and the IOP reductions, and was positively correlated with the decrease in AL at 1 week. The increase in velocity 1 was negatively correlated with preoperative IOP, and IOP reductions. The change in time highest concavity was negatively correlated with IOP before surgery and the decrease in IOP at 1 week. Conclusion: CST is a good choice for measuring IOP, especially when aiming for normalization of IOP after glaucoma surgery.
引用
收藏
页码:166 / 172
页数:7
相关论文
共 25 条
[1]  
Asaoka R, 2015, PLOS ONE, V10
[2]   Repeatability, Reproducibility, and Age Dependency of Dynamic Scheimpflug-Based Pneumotonometer and Its Correlation With a Dynamic Bidirectional Pneumotonometry Device [J].
Bak-Nielsen, Sashia ;
Pedersen, Iben Bach ;
Ivarsen, Anders ;
Hjortdal, Jesper .
CORNEA, 2015, 34 (01) :71-77
[3]   Central corneal thickness and corneal hysteresis associated with glaucoma damage [J].
Congdon, NG ;
Broman, AT ;
Bandeen-Roche, K ;
Grover, D ;
Quigley, HA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (05) :868-875
[4]   Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach [J].
Doughty, MJ ;
Zaman, ML .
SURVEY OF OPHTHALMOLOGY, 2000, 44 (05) :367-408
[5]   Biomechanics and wound healing in the cornea [J].
Dupps, William J., Jr. ;
Wilson, Steven E. .
EXPERIMENTAL EYE RESEARCH, 2006, 83 (04) :709-720
[6]   Intraocular Pressure, Central Corneal Thickness, and Prevalence of Open-Angle Glaucoma: The Los Angeles Latino Eye Study [J].
Francis, Brian A. ;
Varma, Rohit ;
Chopra, Vikas ;
Lai, Mei-Ying ;
Shtir, Corina ;
Azen, Stanley P. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 146 (05) :741-746
[7]   Corvis ST Tonometer for Measuring Postoperative IOP in LASIK Patients [J].
Hong, Jiaxu ;
Yu, Zhiqiang ;
Jiang, Chunhui ;
Zhou, Xingtao ;
Liu, Zuguo ;
Sun, Xinghuai ;
Xu, Jianjiang .
OPTOMETRY AND VISION SCIENCE, 2015, 92 (05) :589-595
[8]   A New Tonometer-The Corvis ST Tonometer: Clinical Comparison with Noncontact and Goldmann Applanation Tonometers [J].
Hong, Jiaxu ;
Xu, Jianjiang ;
Wei, Anji ;
Deng, Sophie X. ;
Cui, Xinhan ;
Yu, Xiaobo ;
Sun, Xinghuai .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (01) :659-665
[9]   Corneal Hysteresis Is Correlated with Reduction in Axial Length After Trabeculectomy [J].
Huang, Chukai ;
Zhang, Mingzhi ;
Huang, Yuqiang ;
Chen, Bin ;
Lam, Dennis S. C. ;
Congdon, Nathan .
CURRENT EYE RESEARCH, 2012, 37 (05) :381-387
[10]   Relationship Between Corneal Biomechanical Properties, Central Corneal Thickness, and Intraocular Pressure Across the Spectrum of Glaucoma [J].
Kaushik, Sushmita ;
Pandav, Surinder Singh ;
Banger, Anupam ;
Aggarwal, Kanika ;
Gupta, Amod .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 153 (05) :840-849