An Online Monitoring System for Salt Deposit Density and Non-soluble Deposit Density of Power Transmission and Transformation Line Insulator

被引:0
|
作者
Su Hainan [1 ]
Du Jikuan [1 ]
Li Junming [1 ]
Liu Yu [2 ]
Gao Yucong [3 ]
Li Xueyan [4 ]
Du Xingkai [1 ]
Yang Sen [1 ]
Ma Jian [5 ]
Gu Guoxing [6 ]
机构
[1] Dandong Power Supply Co, Liaoning Elect Power Co Ltd, State Grid, Dandong, Peoples R China
[2] Harbin Power Supply Co, Heilongjiang Elect Power Co Ltd, State Grid, Harbin, Heilongjiang, Peoples R China
[3] State Grid China Power Finance Co Ltd, Beijing, Peoples R China
[4] Shibei Power Supply Co, Shanghai Elect Power Co Ltd, State Grid, Shibei, Peoples R China
[5] State Grid Yingda Int Holding Grp Co Ltd, Beijing, Peoples R China
[6] Anshan Power Supply Co, Liaoning Elect Power Co Ltd, State Grid, Anshan, Peoples R China
关键词
power transmission and transformation line; insulator; pollution flash; salt deposit density; non-soluble deposit density; online monitoring system;
D O I
10.25236/iwmecs.2019.093
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
The external insulation performance of power transmission and transformation line equipment has a major impact on the operational safety of the power grid. A large number of insulators are incorporated in power systems, and the surface pollution and moisture will seriously affect the electrical characteristics of the insulator, and the dirt accumulated on the surface of the insulator will cause insulator flashover breakdown, affecting the power transmission and transformation line reliability, endangering the operational safety of the grid. In recent years, with the rapid development of China's economy, the old industrial bases in Northeast China saw revitalization. However, the revitalization caused increasingly serious environmental pollution. In particular, haze takes place more frequently, which has seriously affected the anti-pollution of transmission line insulators. Moreover, insulator pollution flashover often results in large and serious power outage.
引用
收藏
页码:480 / 484
页数:5
相关论文
共 19 条
  • [1] Influence of salt/non-soluble deposit density on AC artificial pollution flashover performances of various types insulators
    Yuan, Ji-He
    Jiang, Xing-Liang
    Shu, Li-Chun
    Zhang, Zhi-Jin
    Zhang, Yong-Ji
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2007, 27 (06): : 96 - 100
  • [2] Effect of both salt and non-soluble deposit densities on flashover voltage of 110 kV composite insulator
    Key Laboratory of High Voltage Engineering and Electrical New Technology, Chongqing University, Chongqing 400044, China
    Zhongguo Dianji Gongcheng Xuebao, 2006, 9 (150-154):
  • [3] Image Enhancement Based Detection Method of Non-soluble Deposit Density Levels of Porcelain Insulators
    Huang X.
    Yang L.
    Zhang Y.
    Cao W.
    Li L.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2018, 42 (14): : 151 - 157
  • [4] Measurements of equivalent salt deposit density (ESDD) on a suspension insulator
    An, L
    Jiang, XC
    Han, AD
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2002, 9 (04) : 562 - 568
  • [5] Study of creepage distance of the contaminated insulator in correlation with salt deposit density
    Salam, A
    Ahmad, H
    Ahmad, AS
    Fuad, SA
    Paul, KC
    Tamsir, T
    Buntat, Z
    Piah, MAM
    2000 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS. I & II, 2000, : 215 - 217
  • [6] Equivalent Salt Deposit Density Optical Fiber Sensor for Transmission Lines in Power Grid
    Huang, Xin-Bo
    Xie, Cheng
    Li, Husheng
    IEEE SENSORS JOURNAL, 2017, 17 (01) : 91 - 99
  • [7] Online Measurement of Equivalent Salt Deposit Density by Using Optical Technology
    Cai, Wei
    Deng, Heming
    Zhou, Guohua
    Wang, Jian
    Yang, Fan
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (02) : 409 - 413
  • [8] Combined equivalent salt deposit density prediction model of insulator surface contamination
    Teng, Y. (tengyun.sut@hotmail.com), 1600, Science Press (39):
  • [9] Determination of equivalent salt deposit density using wind velocity for a contaminated insulator
    Salam, MA
    Goswami, H
    Nadir, Z
    JOURNAL OF ELECTROSTATICS, 2005, 63 (01) : 37 - 44
  • [10] Effect of equivalent salt deposit density on flashover voltage of contaminated insulator energized by HVDC
    Salam, MA
    Ahmad, H
    Saadom, Z
    Budin, R
    Tamsir, T
    Buntat, Z
    Piah, MAM
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 821 - 824