Simultaneous Direct Determinations of Na, Mg, K, Ca, P, and S in Biodiesel Fuel by ICP-QMS/QMS after Xylene Dilution: Development and Application of a High-throughput Method for a Homogeneity Assessment of a Candidate Reference Material

被引:6
作者
Zhu, Yanbei [1 ]
Kitamaki, Yuko [1 ]
Numata, Masahiko [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, NMIJ, 1-1-1 Umezono, Tsukuba, Ibaraki 3058563, Japan
关键词
Biodiesel fuel; reference material; homogeneity assessment; xylene dilution; ICP-QMS/QMS; CERTIFIED REFERENCE MATERIAL; OPTICAL-EMISSION SPECTROMETRY; TRACE-ELEMENTS; LIQUID FUELS; SULFUR; OIL; DIGESTION; MATRICES; DIESEL; MS;
D O I
10.2116/analsci.33.209
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Inductively coupled plasma tandem quadrupole mass spectrometry (ICP-QMS/QMS) measurements after xylene dilution were investigated as a method for determining the elements (Na, Mg, K, Ca, P, and S) in a biodiesel fuel (BDF) candidate reference material (RM). Optimizations were respectively carried out for the following parameters to obtain the best performance for measurements: O-2 flow rate (additional gas to the carrier gas) to ensure complete combustion of the xylene solvent in the plasma, plasma power to obtain lower background signal intensities for Na and K, O-2 flow rate (reaction cell gas) to remove any spectral interference with the S, H-2 flow rate so as to remove spectral interference with Ca. After optimization, the lower detection limits of Na, Mg, K, Ca, P, and S were 0.0004, 0.00004, 0.0003, 0.00012, 0.00005, and 0.002 mg kg(-1), respectively. Typical relative standard deviations were 2.1, 2.0, 1.7, 1.1, 2.5, and 2.5% for Na, Mg, K, Ca, P, and S, respectively, where the elemental concentrations in the BDF sample were, respectively, ca. 1 mg kg-1 each for Na, Mg, K and Ca, ca. 2 mg kg(-1) for P, and ca. 6 mg kg(-1) for S. The established method was applied to the homogeneity assessment of a candidate RM of BDF made from palm oil. The relative uncertainties of the homogeneity were 0.3, 0.4, 0.6, 0.3, 1.6, and 0.6% for Na, Mg, K, Ca, P, and S, respectively.
引用
收藏
页码:209 / 215
页数:7
相关论文
共 20 条
[1]   Determination of P, S and Si in biodiesel, diesel and lubricating oil using ICP-MS/MS [J].
Amais, Renata S. ;
Amaral, Clarice D. B. ;
Fialho, Lucimar L. ;
Schiavo, Daniela ;
Nobrega, Joaquim A. .
ANALYTICAL METHODS, 2014, 6 (13) :4516-4520
[2]   A simple dilute-and-shoot procedure for Si determination in diesel and biodiesel by microwave-induced plasma optical emission spectrometry [J].
Amais, Renata S. ;
Donati, George L. ;
Schiavo, Daniela ;
Nobrega, Joaquim A. .
MICROCHEMICAL JOURNAL, 2013, 106 :318-322
[3]   Methods for vanadium determination in fuel oil by GF AAS with microemulsification and acid digestion sampling [J].
Amorim, Fabio Alan C. ;
Lima, Daniel C. ;
Amaro, Joana A. A. ;
Vale, Maria Goreti R. ;
Ferreira, Sergio L. C. .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2007, 18 (08) :1566-1570
[4]  
[Anonymous], 2009, GEN REQ COMP REF MAT
[5]  
[Anonymous], 2006, REF MAT GEN STAT PRI
[6]  
[Anonymous], 2008, K2390 JIS JAP STAND
[7]   Accurate determination of S in organic matrices using isotope dilution ICP-MS/MS [J].
Balcaen, Lieve ;
Woods, Glenn ;
Resano, Martin ;
Vanhaecke, Frank .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (01) :33-39
[8]   Multielemental determination in oil matrices diluted in xylene by ICP-MS with a dynamic reaction cell employing methane as reaction gas for solving specific interferences [J].
de Souza, Jefferson R. ;
Duyck, Christiane B. ;
Fonseca, Teresa C. O. ;
Saint'Pierre, Tatiana D. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (08) :1280-1286
[9]  
Freitas HC, 2015, ANAL METHODS-UK, V7, P7170, DOI [10.1039/c4ay02313g, 10.1039/C4AY02313G]
[10]  
ISO, 2015, ISO/Guide 33:2015(En)