High-intensity focused ultrasound (HIFU) for tumor pain relief in inoperable pancreatic cancer. Evaluation with the pain sensation scale (SES)

被引:0
|
作者
Marinova, M. [1 ]
Strunk, H. M. [1 ]
Rauch, M. [1 ]
Henseler, J. [1 ]
Clarens, T. [1 ]
Bruex, L. [1 ]
Dolscheid-Pommerich, R. [4 ]
Conrad, R. [5 ]
Cuhls, H. [2 ]
Radbruch, L. [2 ]
Schild, H. H. [1 ]
Mucke, M. [2 ,3 ]
机构
[1] Univ Klinikum, Radiol Klin, Siegmund Freud Str 25, D-53105 Bonn, Germany
[2] Univ Klinikum, Klin & Poliklin Palliat Med, Bonn, Germany
[3] Univ Klinikum, Inst Hausarztmed, Bonn, Germany
[4] Univ Klinikum, Inst Klin Chem & Pharmakol, Bonn, Germany
[5] Univ Klinikum, Klin & Poliklin Psychosomat Med & Psychotherapie, Bonn, Germany
来源
SCHMERZ | 2017年 / 31卷 / 01期
关键词
Pancreatic cancer; High-intensity focused ultrasound; Tumor pain; Pain relief; Pain sensation scale; ADENOCARCINOMA; FEASIBILITY; ABLATION; THERAPY;
D O I
10.1007/s00482-016-0140-7
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
High-intensity focused ultrasound (HIFU) in combination with palliative standard therapy is an innovative and effective treatment option for pain reduction in patients with inoperable pancreatic cancer. Evaluation of the effects of additive ultrasound (US)-guided HIFU treatment in inoperable pancreatic cancer on the sensory and affective pain perception using validated questionnaries. In this study 20 patients with locally advanced inoperable pancreatic cancer and tumor-related pain were treated by US-guided HIFU (6 stage III, 12 stage IV according to UICC and 2 with local recurrence after surgery). Ablation was performed using the JC HIFU system (HAIFU, Chongqing, China) with an ultrasonic device for real-time imaging. Clinical assessment included evaluation of pain severity using validated questionnaires with particular attention to the pain sensation scale (SES) with its affective and sensory component and the numeric rating scale (NRS). The average pain reduction after HIFU was 2.87 points on the NRS scale and 57.3 % compared to the mean baseline score (n = 15, 75 %) in 19 of 20 treated patients. Four patients did not report pain relief, however, the previous opioid medication could be stopped (n = 2) or the analgesic dosage could be reduced (n = 2). No pain reduction was achieved in one patient. Furthermore, after HIFU emotional as well as sensory pain aspects were significantly reduced (before vs. 1 week after HIFU, p < 0.05 for all pain scales). US-guided HIFU can be used for effective and early pain relief and reduction of emotional and sensory pain sensation in patients with locally advanced pancreatic cancer.
引用
收藏
页码:31 / 39
页数:9
相关论文
共 50 条
  • [1] Hochintensiver fokussierter Ultraschall (HIFU) zur Linderung tumorbedingter Schmerzen bei inoperablem PankreaskarzinomEvaluation anhand der Schmerzempfindungsskala (SES)High-intensity focused ultrasound (HIFU) for tumor pain relief in inoperable pancreatic cancerEvaluation with the pain sensation scale (SES)
    M. Marinova
    H. M. Strunk
    M. Rauch
    J. Henseler
    T. Clarens
    L. Brüx
    R. Dolscheid-Pommerich
    R. Conrad
    H. Cuhls
    L. Radbruch
    H. H. Schild
    M. Mücke
    Der Schmerz, 2017, 31 (1) : 31 - 39
  • [2] Clinical Use of High-Intensity Focused Ultrasound (HIFU) for Tumor and Pain Reduction in Advanced Pancreatic Cancer
    Strunk, H. M.
    Henseler, J.
    Rauch, M.
    Muecke, M.
    Kukuk, G.
    Cuhls, H.
    Radbruch, L.
    Zhang, L.
    Schild, H. H.
    Marinova, M.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (07): : 662 - 670
  • [3] High-intensity focused ultrasound (HIFU) for pancreatic carcinoma: evaluation of feasibility, reduction of tumour volume and pain intensity
    Marinova, Milka
    Rauch, Maximilian
    Muecke, Martin
    Rolke, Roman
    Gonzalez-Carmona, Maria A.
    Henseler, Jana
    Cuhls, Henning
    Radbruch, Lukas
    Strassburg, Christian P.
    Zhang, Lian
    Schild, Hans H.
    Strunk, Holger M.
    EUROPEAN RADIOLOGY, 2016, 26 (11) : 4047 - 4056
  • [4] High-intensity focused ultrasound (HIFU) for pancreatic carcinoma: evaluation of feasibility, reduction of tumour volume and pain intensity
    Milka Marinova
    Maximilian Rauch
    Martin Mücke
    Roman Rolke
    Maria A. Gonzalez-Carmona
    Jana Henseler
    Henning Cuhls
    Lukas Radbruch
    Christian P. Strassburg
    Lian Zhang
    Hans H. Schild
    Holger M. Strunk
    European Radiology, 2016, 26 : 4047 - 4056
  • [5] Advances of high intensity focused ultrasound (HIFU) for pancreatic cancer
    Li Xiaoping
    Zheng Leizhen
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2013, 29 (07) : 678 - 682
  • [6] Current and Future Clinical Applications of High-Intensity Focused Ultrasound (HIFU) for Pancreatic Cancer
    Jang, Hyun Joo
    Lee, Jae-Young
    Lee, Don-Haeng
    Kim, Won-Hong
    Hwang, Joo Ha
    GUT AND LIVER, 2010, 4 : S57 - S61
  • [7] The Efficacy of High-Intensity Focused Ultrasound (HIFU) in Advanced Pancreatic Cancer
    Bo Xie1 Jiajun Ling2 Weiming Zhang1 Xueqin Huang1 Jihua Zhen1 Yanzhe Huang1 1 Department of Oncology
    Chinese Journal of Clinical Oncology, 2008, (03) : 183 - 186
  • [8] High-intensity focused ultrasound therapy for pancreatic cancer
    Sofuni, Atsushi
    Asai, Yasutsugu
    Mukai, Shuntaro
    Yamamoto, Kenjiro
    Itoi, Takao
    JOURNAL OF MEDICAL ULTRASONICS, 2022,
  • [9] Safety Evaluation of High-Intensity Focused Ultrasound in Patients with Pancreatic Cancer
    Wang, Kun
    Zhu, Huili
    Meng, Zhiqiang
    Chen, Zhen
    Lin, Junhua
    Shen, Yehua
    Gao, Huifeng
    ONKOLOGIE, 2013, 36 (03): : 88 - 92
  • [10] A meta-analysis evaluating the role of high-intensity focused ultrasound (HIFU) as a fourth treatment modality for patients with locally advanced pancreatic cancer
    Fergadi, Maria P.
    Magouliotis, Dimitrios E.
    Rountas, Christos
    Vlychou, Marianna
    Athanasiou, Thanos
    Symeonidis, Dimitris
    Pappa, Polyxeni A.
    Zacharoulis, Dimitris
    ABDOMINAL RADIOLOGY, 2022, 47 (01) : 254 - 264