Complete Intracranial Arterial and Venous Blood Flow Evaluation with 4D Flow MR Imaging

被引:50
作者
Hope, M. D. [1 ]
Purcell, D. D. [1 ]
Hope, T. A. [1 ]
von Morze, C. [1 ]
Vigneron, D. B. [1 ]
Alley, M. T. [2 ]
Dillon, W. P. [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[2] Stanford Univ, Sch Med, Stanford, CA 94305 USA
关键词
PHASE-CONTRAST MRI; ARTERIOVENOUS-MALFORMATIONS; VISUALIZATION; RECONSTRUCTION; HEMODYNAMICS; VOLUNTEERS; RESOLUTION; ANEURYSMS; PATTERNS;
D O I
10.3174/ajnr.A1138
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Time-resolved, 3D velocity-encoded MR imaging (4D Flow) allows for the acquisition of dynamic, multidirectional data on blood flow and has recently been used for the evaluation of intracranial arterial flow. Using a 3T system with optimization of both temporal resolution and k-space subsampling with a combination of parallel imaging and cut-corner acquisition, we present the clinical assessment of a patient with an arteriovenous malformation by providing complete intracranial arterial and venous coverage in a reasonable scan time.
引用
收藏
页码:362 / 366
页数:5
相关论文
共 15 条
[1]   Time-resolved 3D quantitative flow MRI of the major intracranial vessels: Initial experience and comparative evaluation at 1.5T and 3.0T in combination with parallel imaging [J].
Bammer, Roland ;
Hope, Thomas A. ;
Aksoy, Murat ;
Alley, Marcus T. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (01) :127-140
[2]   Concomitant gradient terms in phase contrast MR: Analysis and correction [J].
Bernstein, MA ;
Zhou, XHJ ;
Polzin, JA ;
King, KF ;
Ganin, A ;
Pelc, NJ ;
Glover, GH .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (02) :300-308
[3]   Effect of windowing and zero-filled reconstruction of MRI data on spatial resolution and acquisition strategy [J].
Bernstein, MA ;
Fain, SB ;
Riederer, SJ .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (03) :270-280
[4]   Risk of intracranial arteriovenous malformation rupture due to venous drainage impairment - A theoretical analysis [J].
Hademenos, GJ ;
Massoud, TF .
STROKE, 1996, 27 (06) :1072-1083
[5]   Comparison of flow patterns in ascending aortic aneurysms and volunteers using four-dimensional magnetic resonance velocity mapping [J].
Hope, Thomas A. ;
Markl, Michael ;
Wigstrom, Lars ;
Alley, Marcus T. ;
Miller, D. Craig ;
Herfkens, Robert J. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (06) :1471-1479
[6]   The relationship of coexisting extranidal aneurysms to intracranial hemorrhage in patients harboring brain arteriovenous malformations [J].
Kim, EJ ;
Halim, AX ;
Dowd, CF ;
Lawton, MT ;
Singh, V ;
Bennett, J ;
Young, WL .
NEUROSURGERY, 2004, 54 (06) :1349-1357
[7]   Complications of cerebral arteriovenous malformation embolization: Multivariate analysis of predictive factors [J].
Ledezma, CJ ;
Hoh, BL ;
Carter, BS ;
Pryor, JC ;
Putman, CM ;
Ogilvy, CS .
NEUROSURGERY, 2006, 58 (04) :602-610
[8]   Time-resolved 3-dimensional velocity mapping in the thoracic aorta - Visualization of 3-directional blood flow patterns in healthy volunteers and patients [J].
Markl, M ;
Draney, MT ;
Hope, MD ;
Levin, JM ;
Chan, FP ;
Alley, MT ;
Pelc, NJ ;
Herfkens, RJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (04) :459-468
[9]   Generalized reconstruction of phase contrast MRI: Analysis and correction of the effect of gradient field distortions [J].
Markl, M ;
Bammer, R ;
Alley, MT ;
Elkins, CJ ;
Draney, MT ;
Barnett, A ;
Moseley, ME ;
Glover, GH ;
Pelc, NJ .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (04) :791-801
[10]   Time-resolved three-dimensional phase-contrast MRI [J].
Markl, M ;
Chan, FP ;
Alley, MT ;
Wedding, KL ;
Draney, MT ;
Elkins, CJ ;
Parker, DW ;
Wicker, R ;
Taylor, CA ;
Herfkens, RJ ;
Pelc, NJ .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (04) :499-506