Absorbance Detection in Multireflection Microfluidic Channels Using a Commercial Microplate Reader System

被引:9
作者
Yanagisawa, Naoki [1 ]
Mahmud, Sakur [1 ]
Dutta, Debashis [1 ]
机构
[1] Univ Wyoming, Dept Chem, Laramie, WY 82071 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
CAPILLARY-ELECTROPHORESIS; POLY(DIMETHYLSILOXANE); PRECONCENTRATION; DEVICES; CHIP; CELL;
D O I
10.1021/acs.analchem.0c01961
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Absorbance detection is often prohibited in microfluidic channels due to the limited optical path length available in these systems. However, this optical distance may be significantly increased by guiding the probing light beam along the channel length via multiple reflections by patterned metallic surfaces. In this work, we demonstrate enhanced absorbance detection in glass microfluidic channels using a commercial microplate reader based on this principle, yielding detection limits comparable to that measured on standard microwell plates. This improvement in detectability was realized through careful optimization of the mirror lengths and locations combined with the appropriate design of a microchip holder to suitably position the microchannels in the microplate reader. Additionally, it was determined that the angle by which our device was tilted relative to the horizontal plane played an important role in this optimization. For an optimum choice of parameters accessible with our design, the sensitivity of our absorbance measurements in a 30 mu m-deep channel was improved by as much as 52-fold, raising this quantity to about 84% of the corresponding value realized for 75 mu L samples placed within 7 mm i.d. standard cylindrical microwells. Quantitative ELISAs employing the absorbance detection method were demonstrated on the noted multireflection microchip device for assessing West Nile viral IgM antibody levels in human serum samples yielding analyte detection limits comparable to that measured on standard microwell plates.
引用
收藏
页码:13050 / 13057
页数:8
相关论文
共 39 条
  • [1] Microfluidic devices for cellomics: a review
    Andersson, H
    van den Berg, A
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2003, 92 (03): : 315 - 325
  • [2] Immunomagnetic bead-based cell concentration microdevice for dilute pathogen detection
    Beyor, Nathaniel
    Seo, Tae Seok
    Liu, Peng
    Mathies, Richard A.
    [J]. BIOMEDICAL MICRODEVICES, 2008, 10 (06) : 909 - 917
  • [3] Characterization of masking materials for deep glass micromachining
    Bien, DCS
    Rainey, PV
    Mitchell, SJN
    Gamble, HS
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2003, 13 (04) : S34 - S40
  • [4] A Multi-D-Shaped Optical Fiber for Refractive Index Sensing
    Chen, Chien-Hsing
    Tsao, Tzu-Chein
    Tang, Jaw-Luen
    Wu, Wei-Te
    [J]. SENSORS, 2010, 10 (05): : 4794 - 4804
  • [5] Microfluidic chip-based liquid-liquid extraction and preconcentration using a subnanoliter-droplet trapping technique
    Chen, H
    Fang, Q
    Yin, XF
    Fang, ZL
    [J]. LAB ON A CHIP, 2005, 5 (07) : 719 - 725
  • [6] Chen X., 2017, BIOMED MICRODEVICES, V19
  • [7] De Mello A., 2002, LAB CHIP, V2
  • [8] Surface acoustic wave microfluidics
    Ding, Xiaoyun
    Li, Peng
    Lin, Sz-Chin Steven
    Stratton, Zackary S.
    Nama, Nitesh
    Guo, Feng
    Slotcavage, Daniel
    Mao, Xiaole
    Shi, Jinjie
    Costanzo, Francesco
    Huang, Tony Jun
    [J]. LAB ON A CHIP, 2013, 13 (18) : 3626 - 3649
  • [9] Lab-on-a-chip: microfluidics in drug discovery
    Dittrich, PS
    Manz, A
    [J]. NATURE REVIEWS DRUG DISCOVERY, 2006, 5 (03) : 210 - 218
  • [10] Dolník V, 2000, ELECTROPHORESIS, V21, P41, DOI 10.1002/(SICI)1522-2683(20000101)21:1<41::AID-ELPS41>3.0.CO