Monitoring of pipelines in nuclear power plants by measuring laser-based mechanical impedance

被引:16
作者
Lee, Hyeonseok [1 ]
Sohn, Hoon [1 ]
Yang, Suyoung [1 ]
Yang, Jinyeol [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Civil & Environm Engn, Taejon 305701, South Korea
基金
新加坡国家研究基金会;
关键词
laser-based mechanical impedance (LMI); laser ultrasound; structural health monitoring (SHM); nuclear power plant (NPP); damage detection; LAMB WAVE; GENERATED ULTRASOUND; VIBROMETRY; ALUMINUM; DAMAGE;
D O I
10.1088/0964-1726/23/6/065008
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Using laser-based mechanical impedance (LMI) measurement, this study proposes a damage detection technique that enables structural health monitoring of pipelines under the high temperature and radioactive environments of nuclear power plants (NPPs). The applications of conventional electromechanical impedance (EMI) based techniques to NPPs have been limited, mainly due to the contact nature of piezoelectric transducers, which cannot survive under the high temperature and high radiation environments of NPPs. The proposed LMI measurement technique aims to tackle the limitations of the EMI techniques by utilizing noncontact laser beams for both ultrasound generation and sensing. An Nd: Yag pulse laser is used for ultrasound generation, and a laser Doppler vibrometer is employed for the measurement of the corresponding ultrasound responses. For the monitoring of pipes covered by insulation layers, this study utilizes optical fibers to guide the laser beams to specific target locations. Then, an outlier analysis is adopted for autonomous damage diagnosis. Validation of the proposed LMI technique is carried out on a carbon steel pipe elbow under varying temperatures. A corrosion defect chemically engraved in the specimen is successfully detected.
引用
收藏
页数:10
相关论文
共 44 条
  • [1] [Anonymous], 2002, P 3 WORLD C STRUCT C
  • [2] [Anonymous], 2011, 17 ISOTC
  • [3] [Anonymous], 2009, E07 ASTM COMM
  • [4] Line source representation for laser-generated ultrasound in aluminum
    Bernstein, JR
    Spicer, JB
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2000, 107 (03) : 1352 - 1357
  • [5] High frequency piezoelectric signatures for diagnosis of seismic/blast induced structural damages
    Bhalla, S
    Soh, CK
    [J]. NDT & E INTERNATIONAL, 2004, 37 (01) : 23 - 33
  • [6] Laser Doppler Vibrometry: Development of advanced solutions answering to technology's needs
    Castellini, P.
    Martarelli, M.
    Tomasini, E. P.
    [J]. MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2006, 20 (06) : 1265 - 1285
  • [7] Nondestructive evaluation of cylindrical parts using laser ultrasonics
    Clorennec, D
    Royer, D
    Walaszek, H
    [J]. ULTRASONICS, 2002, 40 (1-8) : 783 - 789
  • [8] Strategies for guided-wave structural health monitoring
    Croxford, A. J.
    Wilcox, P. D.
    Drinkwater, B. W.
    Konstantinidis, G.
    [J]. PROCEEDINGS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2007, 463 (2087): : 2961 - 2981
  • [9] LASER-GENERATED ULTRASOUND - ITS PROPERTIES, MECHANISMS AND MULTIFARIOUS APPLICATIONS
    DAVIES, SJ
    EDWARDS, C
    TAYLOR, GS
    PALMER, SB
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1993, 26 (03) : 329 - 348
  • [10] Giurgiutiu V, 2008, STRUCTURAL HLTH MONI, DOI DOI 10.1016/B978-0-12-088760-6.X5001-6