Fluorimetric monitoring of molecular imprinted polymer recognition events for aluminium

被引:45
作者
Al-Kindy, S
Badia, R
Díaz-García, ME
机构
[1] Sultan Qaboos Univ, Dept Chem, Sultanate, Oman
[2] Univ Oviedo, Fac Chem, Dept Phys & Analyt Chem, Oviedo, Spain
关键词
molecular imprinted polymer; metal ion recognition; sensor; optosensing;
D O I
10.1081/AL-120013581
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Novel molecular imprints were prepared against aluminium. Sensing materials were prepared via non-covalent imprinting technique, using the aluminium(III)-morin chelate as the template. Based on the fluorescent properties of the chelate, it was possible to design a selective optical flow-through sensor for Al3+. The affinity of the polymer binding sites was higher for aluminium than for other di- and trivalent ions (e.g., Be2+, Ca2+, Mg2+, Eu3+, Zn2+, Fe3+), suggesting that the nature of the metal ion, its ionic radius, and the metal-morin stoichiometry play important roles in the ionic recognition.
引用
收藏
页码:1763 / 1774
页数:12
相关论文
共 21 条
[1]   Molecularly imprinted polymers and optical sensing applications [J].
Al-Kindy, S ;
Badía, R ;
Suárez-Rodríguez, JL ;
Díaz-García, ME .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2000, 30 (04) :291-309
[2]  
Arnold BR, 1999, J HOPKINS APL TECH D, V20, P190
[3]  
Baird B, 1999, FOOD TECHNOL-CHICAGO, V53, P13
[4]   Electrochemical detection of aluminium using single-use sensors [J].
Dilleen, JW ;
Birch, BJ ;
Haggett, BGD .
ANALYTICAL COMMUNICATIONS, 1999, 36 (11-12) :363-365
[5]   Determination of aluminum in beverages by automated non-segmented continuous flow analysis with fluorescent detection of the lumogallion complex [J].
Hoch, RL .
ANALYST, 1999, 124 (05) :793-796
[6]   The emerging technique of molecular imprinting and its future impact on biotechnology [J].
Mosbach, K ;
Ramstrom, O .
BIO-TECHNOLOGY, 1996, 14 (02) :163-170
[7]  
Murray GM, 1997, J HOPKINS APL TECH D, V18, P464
[8]   PREPARATION OF CA2+ SELECTIVE SORBENTS BY MOLECULAR IMPRINTING USING POLYMERIZABLE IONOPHORES [J].
ROSATZIN, T ;
ANDERSSON, LI ;
SIMON, W ;
MOSBACH, K .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1991, (08) :1261-1265
[9]   IMMOBILIZED MORIN AS FLUORESCENCE SENSOR FOR DETERMINATION OF ALUMINUM(III) [J].
SAARI, LA ;
SEITZ, WR .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :667-670
[10]  
SCHULMAN SG, 1985, MOL LIMINESCENCE SPE, P371