Characterisation of photovoltaic generators

被引:48
作者
Durisch, W [1 ]
Tille, D
Wörz, A
Plapp, W
机构
[1] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[2] FHU, Tech Coll Ulm, D-89075 Ulm, Germany
[3] FHA, Tech Coll Aalen, D-73428 Aalen, Germany
关键词
photovoltaic test facility; I/V characterisation; solar-cell efficiency; temperature coefficient of efficiency; part-load efficiency; efficiency correlations; shading effects; PSI's solar cell; watch modules; Gratzel's cell; thermophotovoltaic generator;
D O I
10.1016/S0306-2619(99)00115-4
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Reliable knowledge on the performance of different photovoltaic generators (as single cells, modules, laminates, shingles, car roofs, etc.) under actual operating conditions is essential for correct product selection and accurate prediction of their electricity production. For this purpose, an outdoor test facility was erected at the Paul Scherrer Institute, PSI. It consists of a sun-tracked sample holder, electronic loads and a PC-based measuring system. Insolation is measured with pyranometers, pyrheliometers and reference cells. Characterisation of a generator under given test conditions means the precise acquisition of its electrical behaviour under varying load. The generator's efficiency and all the relevant electrical parameters are derived on-line from a series of measured current/voltage (I/V) values. I/V-scans at constant insolation and at different generator temperatures enable the temperature coefficients of the efficiency and the electrical parameters to be determined. Thereafter I/V-scans at different insolations (10-1200 W/m(2)) and air masses (1.1-5) yield (via temperature correction) the insolation dependence of the efficiency at constant temperature. A complete scan takes about 5-15 s. Samples of size varying from 1 by 1 mm up to 1.5 by 1 m can be tested at currents up to 32 A and at voltages up to 120 V. For modelling purposes, the results are represented in the form of correlations, e.g. the efficiency as a function of the operating parameters temperature, insolation and air mass. Results obtained in PSI's test facility were confirmed by the Fraunhofer-Insitut fur Solare Energiesysteme, D-79100 Freiburg, Germany. Measurements are presented from some modules and single cells as well as some efficiency correlations. Results are also presented on lamination losses, on PSI's high efficiency cell, on Gratzel cells and watch modules as well as on shading effects and of a small thermophotovoltaic generator. (C) 1999 Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:273 / 284
页数:12
相关论文
共 10 条
  • [1] BUCHER K, 1993, BMFT STAT SEM PROV
  • [2] Durisch W., 1997, Bulletin des Schweizerischen Elektrotechnischen Vereins & des Verbandes Schweizerischer Elektrizitaetswerke, V88, P35
  • [3] SOLAR IRRADIATION MEASUREMENTS IN JORDAN AND COMPARISONS WITH CALIFORNIAN AND ALPINE DATA
    DURISCH, W
    KELLER, J
    BULGHERONI, W
    KELLER, L
    FRICKER, H
    [J]. APPLIED ENERGY, 1995, 52 (2-3) : 111 - 124
  • [4] DURISCH W, 1997, CHARAKTERISIERUNG GR
  • [5] DURISCH W, 1996, 5 PSI, P35
  • [6] DURISCH W, 1998, NETZVERBUND KLEINSYS
  • [7] DURISCH W, 1996, 9601 PSI
  • [8] DURISCH W, 1987, P ISES SOL WORLD C H, V1, P289
  • [9] Durisch W, 1996, P WORLD REN EN C JUN, P359
  • [10] 1997, ELEKTROTECHNIK, V48, P18