Transition from Paris dosimetry system to 3D image-guided planning in interstitial breast brachytherapy

被引:7
作者
Wiercinska, Judyta [1 ,2 ]
Wronczewska, Anna [3 ]
Kabacinska, Renata [1 ]
Makarewicz, Raman [2 ,3 ]
机构
[1] Ctr Oncol, Dept Med Phys, Bydgoszcz, Poland
[2] Nicolaus Copernicus Univ, Coll Med Bydgoszcz, Chair & Clin Oncol & Brachytherapy, Torun, Poland
[3] Ctr Oncol, Brachytherapy Dept, Bydgoszcz, Poland
关键词
breast cancer; boost; image-based brachytherapy; Paris dosimetry; QUALITY-ASSURANCE; DOSE HOMOGENEITY; IRRADIATION; CANCER; IMPLANTS; BOOST; RECOMMENDATIONS; THERAPY; RESPECT; APBI;
D O I
10.5114/jcb.2015.56492
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The purpose of this study is to evaluate our first experience with 3D image-guided breast brachytherapy and to compare dose distribution parameters between Paris dosimetry system (PDS) and image-based plans. Material and methods: First 49 breast cancer patients treated with 3D high-dose-rate interstitial brachytherapy as a boost were selected for the study. Every patient underwent computed tomography, and the planning target volume (PTV) and organs at risk (OAR) were outlined. Two treatment plans were created for every patient. First, based on a Paris dosimetry system (PDS), and the second one, imaged-based plan with graphical optimization (OPT). The reference isodose in PDS implants was 85%, whereas in OPT plans the isodose was chosen to obtain proper target coverage. Dose and volume parameters (D-90, D-100, V-90, V-100), doses at OARs, total reference air kerma (TRAK), and quality assurance parameters: dose nonuniformity ratio (DNR), dose homogeneity index (DHI), and conformity index (COIN) were used for a comparison of both plans. Results: The mean number of catheters was 7 but the mean for 20 first patients was 5 and almost 9 for the next 29 patients. The mean value of prescribed isodose for OPT plans was 73%. The mean D90 was 88.2% and 105.8%, the D100 was 59.8% and 75.7%, the V-PTV90 was 88.6% and 98.1%, the V-PTV100 was 79.9% and 98.9%, and the TRAK was 0.00375 Gym(-1) and 0.00439 Gym(-1) for the PDS and OPT plans, respectively. The mean DNR was 0.29 and 0.42, the DHI was 0.71 and 0.58, and the COIN was 0.68 and 0.76, respectively. Conclusions: The target coverage in image-guided plans (OPT) was significantly higher than in PDS plans but the dose homogeneity was worse. Also, the value of TRAK increased because of change of prescribing isodose. The learning curve slightly affected our results.
引用
收藏
页码:479 / 484
页数:6
相关论文
共 29 条
  • [1] Computed tomography for excision cavity localization and 3D-treatment planning in partial breast irradiation with high-dose-rate interstitial brachytherapy
    Aristei, Cynthia
    Tarducci, Roberto
    Palumbo, Isabella
    Cavalli, Antonella
    Corazzi, Francesca
    Rulli, Antonio
    Raymondi, Carlo
    Latini, Paolo
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 90 (01) : 43 - 47
  • [2] The importance of the implant quality in APBI - Gliwice experience. Dosimetric evaluation
    Cholewka, Agnieszka
    Szlag, Marta
    Bialas, Brygida
    Kellas-Sleczka, Sylwia
    Slosarek, Krzysztof
    [J]. JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2013, 5 (04) : 227 - 231
  • [3] Cholewka Agnieszka, 2009, J Contemp Brachytherapy, V1, P207
  • [4] 3D CT-based high-dose-rate breast brachytherapy implants: Treatment planning and quality assurance
    Das, RK
    Patel, R
    Shah, H
    Odau, H
    Kuske, RR
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (04): : 1224 - 1228
  • [5] Fijuth Jacek, 2009, J Contemp Brachytherapy, V1, P117
  • [6] Gruszczynska E, 2012, WORLD C BRACH BARC
  • [7] The use of an interstitial boost in the conservative treatment of breast cancer: how to perform it routinely in a radiotherapy department
    Gutierrez, Cristina
    Najjari, Dina
    Martinez, Evelyn
    Botella, Saray
    Eraso, Arantxa
    Pino, Francisco
    Moreno, Ferran
    Pera, Joan
    Guedea, Ferran
    [J]. JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2014, 6 (04) : 397 - 403
  • [8] How to use the Paris system in the year 2001?
    Hennequin, C
    Mazeron, JJ
    Chotin, G
    [J]. RADIOTHERAPY AND ONCOLOGY, 2001, 58 (01) : 5 - 6
  • [9] A comparison of brachytherapy techniques for partial breast irradiation
    Hepel, Jaroslaw T.
    Wazer, David E.
    [J]. BRACHYTHERAPY, 2012, 11 (03) : 163 - 175
  • [10] ICRU, 1997, ICRU report 58