Precise determination of rhenium isotope composition by multi-collector inductively-coupled plasma mass spectrometry

被引:33
|
作者
Miller, Christian A. [1 ,2 ]
Peucker-Ehrenbrink, Bernhard [2 ]
Ball, Lary [2 ,3 ]
机构
[1] WHOI, Dept Marine Chem & Geochem, Woods Hole, MA 02543 USA
[2] MIT, Dept Earth Atmospher & Planetary Sci, Cambridge, MA 02139 USA
[3] Thermo Fisher Sci, N Falmouth, MA 02556 USA
基金
美国国家科学基金会;
关键词
RATIO MEASUREMENT; SOLAR-SYSTEM; NONBIOLOGICAL FRACTIONATION; OSMIUM; DISCRIMINATION; ABUNDANCES; ACCURATE; LEAD; OS; RE;
D O I
10.1039/b818631f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present rhenium (Re) isotope data for commercially available Re reference materials SRM 989, SRM 3143, and Alfa Aesar Specpure (R) Re, as well as two Re solutions made in-house from perrhenic acid and zone-refined flattened-wire ribbon from H. Cross Company. Data were generated by MC-ICPMS (Thermo Fisher Scientific NEPTUNE) using standard-bracketing combined with a tungsten (W) external correction. Intermediate measurement precision (i.e. the precision for similar analytical procedures and measurement conditions on the same instrument over time) is +/- 0.05 parts per thousand (2s) for analyte solution concentrations of 20 ng g(-1) Re and 70 ng g(-1) W; intermediate precision decreases to +/- 0.1 parts per thousand (2s) when respective analyte concentrations are halved to 10 ng g(-1) and 35 ng g(-1). The five Re solutions exhibit an isotopic range of 0.29 parts per thousand, providing the first evidence for stable isotope fractionation of Re. Data are also presented for the Devonian Ohio Shale standard USGS SDO-1; intermediate precision for this natural material (+/- 0.13&, 2s) is comparable to solution standard precisions at equivalent concentrations (10 ng g(-1) Re, 35 ng g(-1) W). Analysis of geochemical materials introduces additional concerns. The low concentration of Re in most materials limits these analyses to Re-rich substrates. Isotopic fractionation occurring during chromatographic purification is nullified by quantitative recovery, and the sample matrix does not introduce fractionation artifacts. Isobaric interference from radiogenic Os-187 can be effectively removed by sparging sample solutions prior to analysis.
引用
收藏
页码:1069 / 1078
页数:10
相关论文
共 50 条
  • [1] Precise analysis of potassium isotopic composition in plant materials by multi-collector inductively coupled plasma mass spectrometry
    He, Mao-Yong
    Ren, Tong Xiang
    Jin, Zhang Dong
    Deng, Li
    Liu, Hai Jiao
    Cheng, Yuan Yuan
    Li, Zheng Yan
    Liu, Xing Xing
    Yang, Yang
    Chang, Hong
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2023, 209
  • [2] Precise and accurate Ga isotope ratio measurements of geological samples by multi-collector inductively coupled plasma mass spectrometry
    Zhang, Yuxu
    Qiao, Pan
    Zhu, Chuanwei
    Fan, Haifeng
    Wen, Hanjie
    ACTA GEOCHIMICA, 2024, 43 (06) : 1054 - 1064
  • [3] Precise and accurate Ga isotope ratio measurements of geological samples by multi-collector inductively coupled plasma mass spectrometry
    Yuxu Zhang
    Pan Qiao
    Chuanwei Zhu
    Haifeng Fan
    Hanjie Wen
    Acta Geochimica, 2024, 43 (06) : 1054 - 1064
  • [4] Rapid determination of 237Np in soil samples by multi-collector inductively-coupled plasma mass spectrometry and gamma spectrometry
    Xiaowei Yi
    Yanmei Shi
    Jiang Xu
    Xiaobing He
    Haitao Zhang
    Jianfeng Lin
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 298 : 1757 - 1761
  • [5] Rapid determination of 237Np in soil samples by multi-collector inductively-coupled plasma mass spectrometry and gamma spectrometry
    Yi, Xiaowei
    Shi, Yanmei
    Xu, Jiang
    He, Xiaobing
    Zhang, Haitao
    Lin, Jianfeng
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 298 (03) : 1757 - 1761
  • [6] Determination of Stable Silicon Isotopes Using Multi-Collector Inductively Coupled Plasma Mass Spectrometry
    Zhang An-Yu
    Zhang Jing
    Zhang Rui-Feng
    Xue Yun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (09) : 1353 - 1358
  • [7] Influence of room temperature on magnesium isotope measurements by multi-collector inductively coupled plasma mass spectrometry
    Zhang, Xing-Chao
    Zhang, An-Yu
    Zhang, Zhao-Feng
    Huang, Fang
    Yu, Hui-Min
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2018, 32 (13) : 1026 - 1030
  • [8] Isotope fractionation during ion beam formation in multi-collector inductively coupled plasma mass spectrometry
    Kivel, Niko
    Guenther-Leopold, Ines
    Vanhaecke, Frank
    Guenther, Detlef
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 76 : 126 - 132
  • [9] Isotope Ratio Analysis of Lead in Blood and Environmental Samples by Multi-collector Inductively Coupled Plasma Mass Spectrometry
    Takagi, Mai
    Yoshinaga, Jun
    Tanaka, Atsushi
    Seyama, Haruhiko
    ANALYTICAL SCIENCES, 2011, 27 (01) : 29 - 35
  • [10] Isotope Ratio Analysis of Lead in Blood and Environmental Samples by Multi-collector Inductively Coupled Plasma Mass Spectrometry
    Mai Takagi
    Jun Yoshinaga
    Atsushi Tanaka
    Haruhiko Seyama
    Analytical Sciences, 2011, 27 : 29 - 35