Detection of oxygen traces in nitrogen- and hydrogen-rich atmosphere

被引:6
作者
Albert, S. [2 ]
Viricelle, J. P. [1 ]
Tournier, G. [1 ]
Breuil, P. [1 ]
Pijolat, C. [1 ]
机构
[1] Ecole Natl Super Mines, Ctr SPIN, Dept MICC, LPMG,UMR 5148, F-42023 St Etienne 02, France
[2] Univ Montpellier 2, Equine Physicochim Mat Desordonnes & Poreux PMDP, CNRS,UMR 5253, Inst Charles Gerhardt Montpellier,ENSCM,UM2,UM1, F-34095 Montpellier 5, France
关键词
Tin oxide; Sensor; Oxygen; Hydrogen; SENSITIVITY; SENSORS; GASES; CO;
D O I
10.1016/j.snb.2009.03.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tin oxide sensors are evaluated to detect traces of oxygen in the range 0-100 ppm both in nitrogen and hydrogen (4.5 vol% H-2 in N-2) atmospheres. In nitrogen, significant relative responses to oxygen are measured at 623 K and 723 K. However, at lower temperature, 523 K, the response strongly decreases. In the presence of hydrogen, on the contrary, interesting responses are measured at 523 K. At higher temperature, 623 K and 723 K, on one hand SnO2 sensors begin to reduce, and on the other hand, oxygen is partly consumed by reaction with hydrogen. Oxygen trace detection (5-100 ppm) is thus only possible in hydrogen atmosphere (4.5 vol% H-2)at 523 K. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:298 / 303
页数:6
相关论文
共 7 条
  • [1] SEMICONDUCTOR METHOD OF DETERMINING OXYGEN MICROCONCENTRATIONS IN DIFFERENT GASES
    GUTMAN, EY
    MYASNIKOV, IA
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) : 210 - 214
  • [2] Lee DW, 2006, J CERAM PROCESS RES, V7, P148
  • [3] Sensitivity of semiconductor gas sensors to hydrogen and oxygen in an inert gas atmosphere
    Malyshev, VV
    Pislyakov, AV
    Krestnikov, IF
    Krutov, VA
    Zaitsev, SN
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 56 (09) : 864 - 870
  • [4] A low temperature sensor for the detection of carbon monoxide in hydrogen
    Mukundan, R
    Brosha, EL
    Garzon, FH
    [J]. SOLID STATE IONICS, 2004, 175 (1-4) : 497 - 501
  • [5] Detection of CO in a reducing, hydrous environment using CuBr as electrolyte
    Reddy, CVG
    Dutta, PK
    Akbar, SA
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2003, 92 (03) : 351 - 355
  • [6] Influence of oxygen concentration in the carrier gas on the response of tin dioxide sensor under hydrogen and methane
    Tournier, G
    Pijolat, C
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1999, 61 (1-3) : 43 - 50
  • [7] CO-sensing properties of doped SnO2 sensors in H2-rich gases
    Wurzinger, O
    Reinhardt, G
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2004, 103 (1-2): : 104 - 110