Diffusion-weighted echo planar MR imaging of the neck at 3 T using integrated shimming: comparison of MR sequence techniques for reducing artifacts caused by magnetic-field inhomogeneities

被引:21
|
作者
Gatidis, Sergios [1 ,4 ]
Graf, Hansjoerg [2 ]
Weiss, Jakob [1 ]
Stemmer, Alto [2 ]
Kiefer, Berthold [2 ]
Nikolaou, Konstantin [1 ]
Notohamiprodjo, Mike [1 ]
Martirosian, Petros [3 ]
机构
[1] Univ Tubingen, Dept Radiol Diagnost & Intervent Radiol, Tubingen, Germany
[2] Siemens Healthcare GmbH, Erlangen, Germany
[3] Univ Tubingen, Dept Radiol, Expt Radiol, Tubingen, Germany
[4] Univ Tubingen Hosp, Dept Radiol, Hoppe Seyler Str 3, D-72076 Tubingen, Germany
关键词
MRI; Diffusion weighted; Echo-planar Imaging; Artifacts; Neck; BRAIN; LESIONS; HEAD; EPI;
D O I
10.1007/s10334-016-0582-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Our objective was to compare available techniques reducing artifacts in echo planar imaging (EPI)-based diffusion-weighed magnetic resonance imaging MRI (DWI) of the neck at 3 Tesla caused by B0-field inhomogeneities. A cylindrical fat-water phantom was equipped with a Maxwell coil allowing for additional linear B0-field variations in z-direction. The effect of increasing strength of this superimposed gradient on image quality was observed using a standard single-shot EPI-based DWI sequence (sEPI), a zoomed single-shot EPI sequence (zEPI), a readout-segmented EPI sequence (rsEPI), and an sEPI sequence with integrated dynamic shimming (intEPI) on a 3-Tesla system. Additionally, ten volunteers were examined over the neck region using these techniques. Image quality was assessed by two radiologists. Scan durations were recorded. With increasing strength of the external gradient, marked distortions, signal loss, and failure of fat suppression were observed using sEPI, zEPI, and rsEPI. These artifacts were markedly reduced using intEPI. Significantly better in vivo image quality was also observed using intEPI compared with the other techniques. Scan time of intEPI was similar to sEPI and zEPI and shorter than rsEPI. The use of integrated 2D shim and frequency adjustment for EPI-based DWI results in a significant improvement in image quality of the head/neck region at 3 Tesla. Combining integrated shimming with rsEPI or zEPI can be expected to provide additional improvements.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 50 条
  • [11] Improvement of renal diffusion-weighted magnetic resonance imaging with readout-segmented echo-planar imaging at 3 T
    Friedli, Iris
    Crowe, Lindsey A.
    Viallon, Magalie
    Porter, David A.
    Martin, Pierre-Yves
    de Seigneux, Sophie
    Vallee, Jean-Paul
    MAGNETIC RESONANCE IMAGING, 2015, 33 (06) : 701 - 708
  • [12] Diffusion-weighted imaging of the head and neck: comparison between integrated slice-specific dynamic shimming and simultaneous multi-slice readout-segmented echo-planar sequences
    Su, Tong
    Zhu, Xiaoli
    Chen, Yu
    Xu, Zhentan
    Chen, Xingming
    Zhang, Tao
    Zhu, Jinxia
    Liu, Wei
    Wang, Xiaoye
    Zhang, Zhuhua
    Feng, Feng
    Jin, Zhengyu
    DENTOMAXILLOFACIAL RADIOLOGY, 2024, 54 (01) : 35 - 42
  • [13] Repeatability of diffusion-weighted magnetic resonance imaging in head and neck cancer at a 1.5 T MR-Linac
    Habrich, Jonas
    Boeke, Simon
    Nachbar, Marcel
    Nikolaou, Konstantin
    Schick, Fritz
    Gani, Cihan
    Zips, Daniel
    Thorwarth, Daniela
    RADIOTHERAPY AND ONCOLOGY, 2022, 174 : 141 - 148
  • [14] Differentiation of Prostatitis and Prostate Cancer by Using Diffusion-weighted MR Imaging and MR-guided Biopsy at 3 T
    Nagel, Klaas N. A.
    Schouten, Martijn G.
    Hambrock, Thomas
    Litjens, Geert J. S.
    Hoeks, Caroline M. A.
    ten Haken, Bennie
    Barentsz, Jelle O.
    Futterer, Jurgen J.
    RADIOLOGY, 2013, 267 (01) : 164 - 172
  • [15] Diffusion-weighted imaging (DWI) in MR mammography (MRM): clinical comparison of echo planar imaging (EPI) and half-Fourier single-shot turbo spin echo (HASTE) diffusion techniques
    P. A. T. Baltzer
    D. M. Renz
    K.-H. Herrmann
    M. Dietzel
    I. Krumbein
    M. Gajda
    O. Camara
    J. R. Reichenbach
    W. A. Kaiser
    European Radiology, 2009, 19 : 1612 - 1620
  • [16] 3-T imaging of the cranial nerves using three-dimensional reversed FISP with diffusion-weighted MR sequence
    Zhang, Zhongwei
    Meng, Quanfei
    Chen, Yingming
    Li, Ziping
    Luo, Boning
    Yang, Zhiyun
    Mao, Lijuan
    Lin, Erjian
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (03) : 454 - 458
  • [17] Reduced Field-of-View Diffusion-Weighted Magnetic Resonance Imaging of the Pancreas: Comparison with Conventional Single-Shot Echo-Planar Imaging
    Kim, Hyungjin
    Lee, Jeong Min
    Yoon, Jeong Hee
    Jang, Jin-Young
    Kim, Sun-Whe
    Ryu, Ji Kon
    Kannengiesser, Stephan
    Ha, Joon Koo
    Choi, Byung Ihn
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (06) : 1216 - 1225
  • [18] Reproducibility of diffusion-weighted magnetic resonance imaging in head and neck cancer assessed on a 1.5 T MR-Linac and comparison to parallel measurements on a 3 T diagnostic scanner
    Habrich, Jonas
    Boeke, Simon
    Fritz, Victor
    Koerner, Elisa
    Nikolaou, Konstantin
    Schick, Fritz
    Gani, Cihan
    Zips, Daniel
    Thorwarth, Daniela
    RADIOTHERAPY AND ONCOLOGY, 2024, 191
  • [19] Comparison of Readout Segmented Echo Planar Imaging (EPI) and EPI With Reduced Field-of-View Diffusion-Weighted Imaging at 3T in Patients With Breast Cancer
    Park, Jin Young
    Shin, Hee Jung
    Shin, Ki Chang
    Sung, Yu Sub
    Choi, Woo Jung
    Chae, Eun Young
    Cha, Joo Hee
    Kim, Hak Hee
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (06) : 1679 - 1688
  • [20] Comparison between turbo spin-echo and echo planar diffusion-weighted imaging of the female pelvis with 3T MRI
    Yoshizako, Takeshi
    Yoshida, Rika
    Asou, Hiroya
    Nakamura, Megumi
    Kitagaki, Hajime
    ACTA RADIOLOGICA OPEN, 2021, 10 (02)