Diffusion-weighted echo planar MR imaging of the neck at 3 T using integrated shimming: comparison of MR sequence techniques for reducing artifacts caused by magnetic-field inhomogeneities

被引:21
|
作者
Gatidis, Sergios [1 ,4 ]
Graf, Hansjoerg [2 ]
Weiss, Jakob [1 ]
Stemmer, Alto [2 ]
Kiefer, Berthold [2 ]
Nikolaou, Konstantin [1 ]
Notohamiprodjo, Mike [1 ]
Martirosian, Petros [3 ]
机构
[1] Univ Tubingen, Dept Radiol Diagnost & Intervent Radiol, Tubingen, Germany
[2] Siemens Healthcare GmbH, Erlangen, Germany
[3] Univ Tubingen, Dept Radiol, Expt Radiol, Tubingen, Germany
[4] Univ Tubingen Hosp, Dept Radiol, Hoppe Seyler Str 3, D-72076 Tubingen, Germany
关键词
MRI; Diffusion weighted; Echo-planar Imaging; Artifacts; Neck; BRAIN; LESIONS; HEAD; EPI;
D O I
10.1007/s10334-016-0582-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Our objective was to compare available techniques reducing artifacts in echo planar imaging (EPI)-based diffusion-weighed magnetic resonance imaging MRI (DWI) of the neck at 3 Tesla caused by B0-field inhomogeneities. A cylindrical fat-water phantom was equipped with a Maxwell coil allowing for additional linear B0-field variations in z-direction. The effect of increasing strength of this superimposed gradient on image quality was observed using a standard single-shot EPI-based DWI sequence (sEPI), a zoomed single-shot EPI sequence (zEPI), a readout-segmented EPI sequence (rsEPI), and an sEPI sequence with integrated dynamic shimming (intEPI) on a 3-Tesla system. Additionally, ten volunteers were examined over the neck region using these techniques. Image quality was assessed by two radiologists. Scan durations were recorded. With increasing strength of the external gradient, marked distortions, signal loss, and failure of fat suppression were observed using sEPI, zEPI, and rsEPI. These artifacts were markedly reduced using intEPI. Significantly better in vivo image quality was also observed using intEPI compared with the other techniques. Scan time of intEPI was similar to sEPI and zEPI and shorter than rsEPI. The use of integrated 2D shim and frequency adjustment for EPI-based DWI results in a significant improvement in image quality of the head/neck region at 3 Tesla. Combining integrated shimming with rsEPI or zEPI can be expected to provide additional improvements.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 50 条
  • [1] Diffusion-weighted echo planar MR imaging of the neck at 3 T using integrated shimming: comparison of MR sequence techniques for reducing artifacts caused by magnetic-field inhomogeneities
    Sergios Gatidis
    Hansjörg Graf
    Jakob Weiß
    Alto Stemmer
    Berthold Kiefer
    Konstantin Nikolaou
    Mike Notohamiprodjo
    Petros Martirosian
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2017, 30 : 57 - 63
  • [2] Integrated slice-specific dynamic shimming for whole-body diffusion-weighted MR imaging at 1.5 T
    McElroy, Sarah
    Winfield, Jessica M.
    Westerland, Olwen
    Charles-Edwards, Geoff
    Bell, Joanna
    Neji, Radhouene
    Stemmer, Alto
    Kiefer, Berthold
    Streetly, Matthew
    Goh, Vicky
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2021, 34 (04) : 513 - 521
  • [3] Diffusion-weighted imaging of the kidney: comparison between simultaneous multi-slice and integrated slice-by-slice shimming echo planar sequence
    Zhang, G.
    Sun, H.
    Qian, T.
    An, J.
    Shi, B.
    Zhou, H.
    Liu, Y.
    Peng, X.
    Chen, L.
    Jin, Z.
    CLINICAL RADIOLOGY, 2019, 74 (04) : 325.e1 - 325.e8
  • [4] Hemorrhagic and nonhemorrhagic stroke: Diagnosis with diffusion-weighted and T2-weighted echo-planar MR imaging
    Ebisu, T
    Tanaka, C
    Umeda, M
    Kitamura, M
    Fukunaga, M
    Aoki, I
    Sato, H
    Higuchi, T
    Naruse, S
    Horikawa, Y
    Ueda, S
    RADIOLOGY, 1997, 203 (03) : 823 - 828
  • [5] Image Quality and ADC Assessment in Turbo Spin-Echo and Echo-Planar Diffusion-Weighted MR Imaging of Tumors of the Head and Neck
    Panyarak, Wannakamon
    Chikui, Toru
    Yamashita, Yasuo
    Kamitani, Takeshi
    Yoshiura, Kazunori
    ACADEMIC RADIOLOGY, 2019, 26 (10) : E305 - E316
  • [6] Integrated slice-specific dynamic shimming for whole-body diffusion-weighted MR imaging at 1.5 T
    Sarah McElroy
    Jessica M. Winfield
    Olwen Westerland
    Geoff Charles-Edwards
    Joanna Bell
    Radhouene Neji
    Alto Stemmer
    Berthold Kiefer
    Matthew Streetly
    Vicky Goh
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2021, 34 : 513 - 521
  • [7] Diffusion-weighted imaging (DWI) in MR mammography (MRM): clinical comparison of echo planar imaging (EPI) and half-Fourier single-shot turbo spin echo (HASTE) diffusion techniques
    Baltzer, P. A. T.
    Renz, D. M.
    Herrmann, K. -H.
    Dietzel, M.
    Krumbein, I.
    Gajda, M.
    Camara, O.
    Reichenbach, J. R.
    Kaiser, W. A.
    EUROPEAN RADIOLOGY, 2009, 19 (07) : 1612 - 1620
  • [8] Readout-segmented echo-planar imaging in diffusion-weighted MR imaging of acute infarction of the brainstem and posterior fossa: comparison of single-shot echo-planar diffusion-weighted sequences
    Byeon, Jonghyun
    Kim, Jee Young
    Cho, A-Hyun
    CLINICAL IMAGING, 2015, 39 (05) : 765 - 769
  • [9] Readout-segmented echo-planar imaging improves the image quality of diffusion-weighted MR imaging in rectal cancer: Comparison with single-shot echo-planar diffusion-weighted sequences
    Xia, Chun-chao
    Liu, Xi
    Peng, Wan-lin
    Li, Lei
    Zhang, Jin-ge
    Meng, Wen-jian
    Deng, Xiang-bing
    Zuo, Pan-li
    Li, Zhen-lin
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (10) : 1818 - 1823
  • [10] Combination of integrated dynamic shimming and readout-segmented echo planar imaging for diffusion weighted MRI of the head and neck region at 3 Tesla
    Walter, Sven S.
    Liu, Wei
    Stemmer, Alto
    Martirosian, Petros
    Nikolaou, Konstantin
    Notohamiprodjo, Mike
    Gatidis, Sergios
    MAGNETIC RESONANCE IMAGING, 2017, 42 : 32 - 36