High Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-weighted MR Images: Relationship with Increasing Cumulative Dose of a Gadolinium-based Contrast Material

被引:1031
|
作者
Kanda, Tomonori [1 ]
Ishii, Kazunari [2 ]
Kawaguchi, Hiroki [1 ]
Kitajima, Kazuhiro [3 ]
Takenaka, Daisuke [1 ]
机构
[1] Hyogo Canc Ctr, Dept Diagnost Radiol, Akashi, Hyogo, Japan
[2] Kinki Univ, Fac Med, Dept Radiol, Osakasayama, Osaka, Japan
[3] Kobe Univ, Grad Sch Med, Dept Radiol, Kobe, Hyogo 657, Japan
关键词
HYPERINTENSE BASAL GANGLIA; BRAIN;
D O I
10.1148/radiol.13131669
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To explore any correlation between the number of previous gadolinium-based contrast material administrations and high signal intensity (SI) in the dentate nucleus and globus pallidus on unenhanced T1-weighted magnetic resonance (MR) images. Materials and Methods: The institutional review board approved this study, waiving the requirement to obtain written informed consent. A group of 381 consecutive patients who had undergone brain MR imaging was identified for cross-sectional analysis. For longitudinal analysis, 19 patients who had undergone at least six contrast-enhanced examinations were compared with 16 patients who had undergone at least six unenhanced examinations. The mean SIs of the dentate nucleus, pons, globus pallidus, and thalamus were measured on unenhanced T1-weighted images. The dentate nucleus-to-pons SI ratio was calculated by dividing the SI in the dentate nucleus by that in the pons, and the globus pallidus-to-thalamus SI ratio was calculated by dividing the SI in the globus pallidus by that in the thalamus. Stepwise regression analysis was undertaken in the consecutive patient group to detect any relationship between the dentate nucleus-to-pons or globus pallidus-to-thalamus SI ratio and previous gadolinium- based contrast material administration or other factors. A random coefficient model was used to evaluate for longitudinal analysis. Results: The dentate nucleus-to-pons SI ratio showed a significant correlation with the number of previous gadolinium-based contrast material administrations (P <.001; regression coefficient, 0.010; 95% confidence interval [CI]: 0.009, 0.011; standardized regression coefficient, 0.695). The globus pallidus-to-thalamus SI ratio showed a significant correlation with the number of previous gadolinium-based contrast material administrations (P <.001; regression coefficient, 0.004; 95% CI: 0.002, 0.006; standardized regression coefficient, 0.288), radiation therapy (P=.009; regression coefficient, -0.014; 95% CI: -0.025, -0.004; standardized regression coefficient, -0.151), and liver function (P=.031; regression coefficient, 0.023; 95% CI: 0.002, 0.044; standardized regression coefficient, 0.107). The dentate nucleus-to-pons and globus pallidus-to-thalamus SI ratios in patients who had undergone contrast-enhanced examinations were significantly greater than those of patients who had undergone unenhanced examinations(P <.001 for both). Conclusion: High SI in the dentate nucleus and globus pallidus on unenhanced T1-weighted images may be a consequence of the number of previous gadolinium- based contrast material administrations. (C) RSNA, 2013
引用
收藏
页码:834 / 841
页数:8
相关论文
共 50 条
  • [21] Repeated administrations of macrocyclic gadolinium based contrast agents do not cause increased signal intensity in dentate nucleus and globus pallidus on T1-weighted unenhanced magnetic resonance images: confirmed safety in multiple sclerosis
    Sartori, A.
    Gennari, A. G.
    Zorzenon, I.
    Dinoto, A.
    Bratina, A.
    Ukmar, M.
    Bosco, A.
    Cova, M. A.
    Manganotti, P.
    MULTIPLE SCLEROSIS JOURNAL, 2017, 23 : 1009 - 1010
  • [22] Changes in signal intensity in the dentate nucleus at unenhanced T1-weighted magnetic resonance imaging depending on class of previously used gadolinium-based contrast agent
    Kasper, Eileen
    Schemuth, Haemi Phaedra
    Horry, Samantha
    Kinner, Sonja
    PEDIATRIC RADIOLOGY, 2018, 48 (05) : 686 - 693
  • [23] Changes in signal intensity in the dentate nucleus at unenhanced T1-weighted magnetic resonance imaging depending on class of previously used gadolinium-based contrast agent
    Eileen Kasper
    Haemi Phaedra Schemuth
    Samantha Horry
    Sonja Kinner
    Pediatric Radiology, 2018, 48 : 686 - 693
  • [24] Signal intensity change on unenhanced T1-weighted images in dentate nucleus and globus pallidus after multiple administrations of gadoxetate disodium: an intraindividual comparative study
    Giorgio Conte
    Lorenzo Preda
    Emilia Cocorocchio
    Sara Raimondi
    Caterina Giannitto
    Marta Minotti
    Francesca De Piano
    Giuseppe Petralia
    Pier Francesco Ferrucci
    Massimo Bellomi
    European Radiology, 2017, 27 : 4372 - 4378
  • [25] Signal intensity change on unenhanced T1-weighted images in dentate nucleus and globus pallidus after multiple administrations of gadoxetate disodium: an intraindividual comparative study
    Conte, Giorgio
    Preda, Lorenzo
    Cocorocchio, Emilia
    Raimondi, Sara
    Giannitto, Caterina
    Minotti, Marta
    De Piano, Francesca
    Petralia, Giuseppe
    Ferrucci, Pier Francesco
    Bellomi, Massimo
    EUROPEAN RADIOLOGY, 2017, 27 (10) : 4372 - 4378
  • [26] Pediatric Brain: Repeated Exposure to Linear Gadolinium-based Contrast Material Is Associated with Increased Signal Intensity at Unenhanced T1-weighted MR Imaging
    Flood, Thomas F.
    Stence, Nicholas V.
    Maloney, John A.
    Mirsky, David M.
    RADIOLOGY, 2017, 282 (01) : 222 - 228
  • [27] Linear gadolinium-based contrast agent (gadodiamide and gadopentetate dimeglumine)-induced high signal intensity on unenhanced T1-weighted images in pediatric patients
    Ichikawa, Shintaro
    Omiya, Yoshie
    Onishi, Hiroshi
    Motosugi, Utaroh
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (04) : 1046 - 1052
  • [30] Signal intensity in dentate nucleus and globus pallidus on T1-weighted unenhanced magnetic resonance images after repeated administrations of macrocyclic GBCAs: does the type of agent matter?
    Sartori, A.
    Gennari, A. G.
    Zorzenon, I.
    Dinoto, A.
    Morelli, M. E.
    Bratina, A.
    Ukmar, M.
    Bosco, A.
    Cova, M. A.
    Manganotti, P.
    MULTIPLE SCLEROSIS JOURNAL, 2018, 24 : 433 - 434