Collimator choice in cardiac SPECT with I-123-labeled tracers

被引:18
作者
Inoue, Y
Shirouzu, I
Machida, T
Yoshizawa, Y
Akita, F
Minami, M
Ohtomo, K
机构
[1] Univ Tokyo, Inst Med Sci, Dept Radiol, Minato Ku, Tokyo 1088639, Japan
[2] Univ Tokyo, Grad Sch Med, Dept Radiol, Tokyo 1088639, Japan
[3] NTT EC, Kanto Med Ctr, Dept Radiol, Tokyo, Japan
关键词
iodine; 123; collimator; heart; scatter correction;
D O I
10.1016/j.nuclcard.2004.04.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Septal penetration of high-energy photons may degrade the quality of single photon emission computed tomography (SPECT) of the heart with iodine 123-labeled tracers. We investigated the impact of collimator choice on cardiac SPECT with I-123. Methods and Results. SPECT of a thoracic phantom containing I-123 solution was performed with a low-energy high-resolution (LEHR) collimator, special LEHR (SLEHR) collimator, and medium-energy (ME) collimator, and the cavity-to-myocardium contrast, wall thickness, and defect contrast were compared among the collimators. For all indices, use of the SLEHR collimator yielded the best results. Comparison between the LEHR and ME collimators revealed that the cavity-to-myocardium contrast and contrast for large defects were better with the ME collimator, whereas wall thickness and contrast for small defects were similar. Scatter correction by the triple-energy window method improved the indices examined; however, the superiority of the SLEHR collimator was still observed after correction. Conclusions. Collimator choice substantially influences the quality of cardiac SPECT with I-123-labeled agents, and an appropriate collimator needs to be selected in consideration of septal penetration and spatial resolution.
引用
收藏
页码:433 / 439
页数:7
相关论文
共 24 条
[1]   IMAGING I-123 WITH A SCINTILLATION CAMERA - STUDY OF DETECTION PERFORMANCE AND QUALITY FACTOR CONCEPTS [J].
BOLMSJO, MS ;
PERSSON, BRR ;
STRAND, SE .
PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (02) :266-277
[2]   SCATTER CORRECTION IN SCINTIGRAPHY - THE STATE-OF-THE-ART [J].
BUVAT, I ;
BENALI, H ;
TODDPOKROPEK, A ;
DIPAOLA, R .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1994, 21 (07) :675-694
[3]   Optimal collimator choice for sequential iodine-123 and technetium-99m imaging [J].
DeGeeter, F ;
Franken, PR ;
Defrise, M ;
Andries, H ;
Saelens, E ;
Bossuyt, A .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (07) :768-774
[4]   Influence of high-energy photons on the spectrum of iodine-123 with low- and medium-energy collimators:: consequences for imaging with 123I-labelled compounds in clinical practice [J].
Dobbeleir, AA ;
Hambye, ASE ;
Franken, PR .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (06) :655-658
[5]  
Dobbeleir AA, 1999, J NUCL MED, V40, P707
[6]  
Fleming JS, 1996, J NUCL MED, V37, P1832
[7]  
GILLAND DR, 1994, J NUCL MED, V35, P1707
[8]   Effects of scatter and attenuation correction on quantitative analysis of β-CIT brain SPET [J].
Hashimoto, J ;
Sasaki, T ;
Ogawa, K ;
Kubo, A ;
Motomura, N ;
Ichihara, T ;
Amano, T ;
Fukuuchi, Y .
NUCLEAR MEDICINE COMMUNICATIONS, 1999, 20 (02) :159-165
[9]   Metalodobenzylguanidine scintigraphy of the heart: what have we learnt clinically? [J].
Hattori, N ;
Schwaiger, M .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (01) :1-6
[10]  
ICHIHARA T, 1993, J NUCL MED, V34, P2216