Dynamics of ion beam emission in a low pressure plasma focus device

被引:3
作者
Lim, Lian-Kuang [1 ]
Yap, Seong-Ling [1 ]
Nee, Chen-Hon [2 ]
Yap, Seong-Shan [2 ]
机构
[1] Univ Malaya, Dept Phys, Plasma Technol Res Ctr, Fac Sci, Kuala Lumpur 50603, Malaysia
[2] Multimedia Univ, Fac Engn, Cyberjaya 63100, Selangor, Malaysia
关键词
plasma focus; ion beam; x-ray; electron beam; acceleration mechanism; time of flight; X-RAY-EMISSION; NEUTRON-PRODUCTION; DEUTERON BEAM; OPTIMIZATION; GENERATION;
D O I
10.1088/1361-6587/abcfdd
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The plasma that accelerates and compresses in the formation of the pinch in dense plasma focus devices has been found to be an abundant source of multiple radiations like ion beams and x-rays. In this work, the ion beam and x-ray emissions from a 2.7 kJ (13.5 kV, 30 mu F) plasma focus device operated at pressure below 1 mbar were investigated. The time profile of the ion beam emission was analysed from the simultaneously measured ion beam, soft and hard x-ray signals using biased ion collectors, BPX 65 silicon PIN diode and a scintillator-photomultiplier tube assembly. Time resolved analysis of the emissions revealed that the emission of the ion beam corresponded to several different pinching instances. Two components of the ion beam were identified. An ion beam of lower energy but higher intensity was emitted followed by an ion beam of higher energy but lower intensity in the first plasma pinch. The ion beam emitted from the first plasma pinch also has higher energy than subsequent plasma pinches. The emission was found to be associated with the amplitude of voltage spike. The results from ion beam and electron beams suggest that they were emitted by the same localized electric field induced in the pinched plasma. The strongest plasma focus discharge indicated by sharp voltage spike of high amplitude and highest ion beam energy were both observed at 0.2 mbar. The average energy of the ion beam obtained is (53 +/- 13) keV. At this optimum condition, the ions beam with the highest energy also led to the highest hard x-ray emission.
引用
收藏
页数:11
相关论文
共 50 条
[21]   Beam acceleration in plasma focus device [J].
Antanasijevic, R ;
Banjanac, R ;
Dragic, A ;
Maric, Z ;
Stanojevic, J ;
Udovicic, V ;
Vukovic, J .
RADIATION MEASUREMENTS, 2001, 34 (1-6) :615-616
[22]   Low-Energy Plasma Focus Device as an Electron Beam Source [J].
Khan, Muhammad Zubair ;
Ling, Yap Seong ;
Yaqoob, Ibrar ;
Kumar, Nitturi Naresh ;
Kuang, Lim Lian ;
San, Wong Chiow .
SCIENTIFIC WORLD JOURNAL, 2014,
[23]   Temporal and spatial study of neon ion emission from a plasma focus device [J].
Bhuyan, M. ;
Neog, N. K. ;
Mohanty, S. R. ;
Rao, C. V. S. ;
Raole, P. M. .
PHYSICS OF PLASMAS, 2011, 18 (03)
[24]   Development of multi faraday cup assembly for ion beam measurements from a low energy plasma focus device [J].
Mohanty, SR ;
Bhuyan, H ;
Neog, NK ;
Rout, RK ;
Hotta, E .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (7A) :5199-5205
[25]   Time resolved studies on X-rays and charged particles emission from a low energy plasma focus device [J].
Neog, N. K. ;
Mohanty, S. R. ;
Borthakur, T. K. .
PHYSICS LETTERS A, 2008, 372 (13) :2294-2299
[26]   Studies on Ion Emission from the Plasma Focus Device by Using Ion Collector and Track Detector [J].
M. Bhuyan ;
N. K. Neog ;
S. R. Mohanty ;
C. V. S. Rao ;
P. M. Raole .
Journal of Fusion Energy, 2010, 29 :177-180
[27]   Characteristics of ion beams produced in a plasma focus device [J].
Takao, K ;
Doi, Y ;
Hirata, S ;
Shiotani, M ;
Kitamura, I ;
Takahashi, T ;
Masugata, K .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2001, 40 (2B) :1013-1015
[28]   Nitrogen ion spectrum from a low energy plasma focus device [J].
Kelly, H ;
Lepone, A ;
Marquez, A .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 1997, 25 (03) :455-459
[29]   Estimation of electron temperature and radiation emission of a low energy (2.2 kJ) plasma focus device [J].
M. Z. Khan ;
S. L. Yap ;
C. S. Wong .
Indian Journal of Physics, 2014, 88 :97-102
[30]   Ion beam measurements of a dense plasma focus device using CR 39 nuclear track detectors [J].
Ngoi, S. K. ;
Yap, S. L. ;
Wong, C. S. ;
Saadah, A. R. .
CURRENT ISSUES OF PHYSICS IN MALAYSIA, 2008, 1017 :347-+