Bioprosthetic Valve Thrombosis Versus Structural Failure Clinical and Echocardiographic Predictors

被引:218
作者
Egbe, Alexander C. [1 ]
Pislaru, Sorin V. [1 ]
Pellikka, Patricia A. [1 ]
Poterucha, Joseph T. [1 ]
Schaff, Hartzell V. [2 ]
Maleszewski, Joseph J. [3 ]
Connolly, Heidi M. [1 ]
机构
[1] Mayo Clin, Div Cardiovasc Dis, Rochester, MN 55905 USA
[2] Mayo Clin, Div Cardiovasc Surg, Rochester, MN 55905 USA
[3] Mayo Clin, Anat Pathol, Rochester, MN 55905 USA
关键词
atrial fibrillation; cusp; Doppler gradient; valvular heart disease; vitamin K antagonist; REPLACEMENT; POSITION; RISK;
D O I
10.1016/j.jacc.2015.09.022
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Bioprosthetic valve thrombosis (BPVT) is considered uncommon; this may be related to the fact that it is often unrecognized. Recent data suggest that BPVT responds to vitamin K antagonists, emphasizing the need for reliable diagnosis. OBJECTIVES This study sought to determine the diagnostic features of BPVT and to formulate a diagnostic model for BPVT. METHODS Cases of BPVT occurring between 1997 and 2013 were identified from the Mayo Clinic pathology database. Patients with BPVT were matched 1: 2 for age, sex, and prosthesis position with patients whose valves were explanted for structural failure. We formulated a diagnostic model for BPVT using multivariate linear logistic regression and receiver operating characteristic. RESULTS Among 397 consecutive cases of explanted bioprostheses, there were 46 cases of BPVT (11.6%; aortic 29, mitral 9, tricuspid 7, pulmonary 1), mean age was 63 years, and 68% were male. Thirty (65%) cases occurred >12 months post-implantation; median bioprosthetic valve longevity was 24 months (cases) versus 108 months (controls) (p < 0.001). Independent predictors of BPVT were >50% increase in mean echo-Doppler gradient from baseline within 5 years (odds ratio [OR]: 12.7), paroxysmal atrial fibrillation (OR: 5.19), subtherapeutic international normalized ratio (OR: 7.37), increased cusp thickness (OR: 12.2), and abnormal cusp mobility (OR: 6.94). Presence of all 5 diagnostic features was predictive of BPVT with 76% sensitivity, 93% specificity, 85% positive predictive value, and 89% negative predictive value (p < 0.001). CONCLUSIONS BPVT is not uncommon and can occur several years after surgery. A combination of clinical and echocardiographic features can reliably diagnose BPVT. (C) 2015 by the American College of Cardiology Foundation.
引用
收藏
页码:2285 / 2294
页数:10
相关论文
共 18 条
  • [11] Oliver J M, 1996, J Am Soc Echocardiogr, V9, P691, DOI 10.1016/S0894-7317(96)90066-8
  • [12] Bioprosthetic valve thrombosis: The eyes will not see what the mind does not know
    Pislaru, Sorin V.
    Pellikka, Patricia A.
    Schaff, Hartzell V.
    Connolly, Heidi M.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 149 (06)
  • [13] Misconceptions, diagnostic challenges and treatment opportunities in bioprosthetic valve thrombosis: lessons from a case series
    Pislaru, Sorin V.
    Hussain, Imad
    Pellikka, Patricia A.
    Maleszewski, Joseph J.
    Hanna, Richard D.
    Schaff, Hartzell V.
    Connolly, Heidi M.
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2015, 47 (04) : 725 - 732
  • [14] THIENE G, 1980, J THORAC CARDIOV SUR, V80, P414
  • [15] Guidelines on the management of valvular heart disease (version 2012)
    Vahanian, Alec
    Alfieri, Ottavio
    Andreotti, Felicita
    Antunes, Manuel J.
    Baron-Esquivias, Gonzalo
    Baumgartner, Helmut
    Borger, Michael Andrew
    Carrel, Thierry P.
    De Bonis, Michele
    Evangelista, Arturo
    Falk, Volkmar
    Iung, Bernard
    Lancellotti, Patrizio
    Pierard, Luc
    Price, Susanna
    Schaefers, Hans-Joachim
    Schuler, Gerhard
    Stepinska, Janina
    Karl, Swedberg
    Takkenberg, Johanna
    Von Oppell, Ulrich Otto
    Windecker, Stephan
    Luis Zamorano, Jose
    Zembala, Marian
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 42 (04) : S1 - S44
  • [16] The fate of Hancock II porcine valve recipients 25 years after implant
    Valfre, Carlo
    Lus, Paolo
    Minniti, Giuseppe
    Salvador, Loris
    Bottio, Tomaso
    Cesari, Francesco
    Rizzoli, Giulio
    Gerosa, Gino
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2010, 38 (02) : 141 - 145
  • [17] ZEIEN LB, 1990, ARCH PATHOL LAB MED, V114, P933
  • [18] Recommendations for Evaluation of Prosthetic Valves With Echocardiography and Doppler Ultrasound A Report From the American Society of Echocardiography's Guidelines and Standards Committee and the Task Force on Prosthetic Valves, Developed in Conjunction With the American College of Cardiology Cardiovascular Imaging Committee, Cardiac Imaging Committee of the American Heart Association, the European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography and the Canadian Society of Echocardiography, Endorsed by the American College of Cardiology Foundation, American Heart Association, European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography, and Canadian Society of Echocardiography
    Zoghbi, William A.
    Chambers, John B.
    Dumesnil, Jean G.
    Foster, Elyse
    Gottdiener, John S.
    Grayburn, Paul A.
    Khandheria, Bijoy K.
    Levine, Robert A.
    Marx, Gerald Ross
    Miller, Fletcher A., Jr.
    Nakatani, Satoshi
    Quinones, Miguel A.
    Rakowski, Harry
    Rodriguez, L. Leonardo
    Swaminathan, Madhav
    Waggoner, Alan D.
    Weissman, Neil J.
    Zabalgoitia, Miguel
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (09) : 975 - 1014