Bioprosthetic Valve Thrombosis Versus Structural Failure Clinical and Echocardiographic Predictors

被引:218
作者
Egbe, Alexander C. [1 ]
Pislaru, Sorin V. [1 ]
Pellikka, Patricia A. [1 ]
Poterucha, Joseph T. [1 ]
Schaff, Hartzell V. [2 ]
Maleszewski, Joseph J. [3 ]
Connolly, Heidi M. [1 ]
机构
[1] Mayo Clin, Div Cardiovasc Dis, Rochester, MN 55905 USA
[2] Mayo Clin, Div Cardiovasc Surg, Rochester, MN 55905 USA
[3] Mayo Clin, Anat Pathol, Rochester, MN 55905 USA
关键词
atrial fibrillation; cusp; Doppler gradient; valvular heart disease; vitamin K antagonist; REPLACEMENT; POSITION; RISK;
D O I
10.1016/j.jacc.2015.09.022
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Bioprosthetic valve thrombosis (BPVT) is considered uncommon; this may be related to the fact that it is often unrecognized. Recent data suggest that BPVT responds to vitamin K antagonists, emphasizing the need for reliable diagnosis. OBJECTIVES This study sought to determine the diagnostic features of BPVT and to formulate a diagnostic model for BPVT. METHODS Cases of BPVT occurring between 1997 and 2013 were identified from the Mayo Clinic pathology database. Patients with BPVT were matched 1: 2 for age, sex, and prosthesis position with patients whose valves were explanted for structural failure. We formulated a diagnostic model for BPVT using multivariate linear logistic regression and receiver operating characteristic. RESULTS Among 397 consecutive cases of explanted bioprostheses, there were 46 cases of BPVT (11.6%; aortic 29, mitral 9, tricuspid 7, pulmonary 1), mean age was 63 years, and 68% were male. Thirty (65%) cases occurred >12 months post-implantation; median bioprosthetic valve longevity was 24 months (cases) versus 108 months (controls) (p < 0.001). Independent predictors of BPVT were >50% increase in mean echo-Doppler gradient from baseline within 5 years (odds ratio [OR]: 12.7), paroxysmal atrial fibrillation (OR: 5.19), subtherapeutic international normalized ratio (OR: 7.37), increased cusp thickness (OR: 12.2), and abnormal cusp mobility (OR: 6.94). Presence of all 5 diagnostic features was predictive of BPVT with 76% sensitivity, 93% specificity, 85% positive predictive value, and 89% negative predictive value (p < 0.001). CONCLUSIONS BPVT is not uncommon and can occur several years after surgery. A combination of clinical and echocardiographic features can reliably diagnose BPVT. (C) 2015 by the American College of Cardiology Foundation.
引用
收藏
页码:2285 / 2294
页数:10
相关论文
共 18 条
  • [1] Comprehensive Echocardiographic Assessment of the Hemodynamic Parameters of 285 Tricuspid Valve Bioprostheses Early after Implantation
    Blauwet, Lori A.
    Danielson, Gordon K.
    Burkhart, Harold M.
    Dearani, Joseph A.
    Malouf, Joseph F.
    Connolly, Heidi M.
    Hodge, David O.
    Herges, Regina M.
    Miller, Fletcher A., Jr.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (10) : 1045 - U72
  • [2] Early thrombosis risk in patients with biologic valves in the aortic position
    Brown, Morgan L.
    Park, Soon J.
    Sundt, Thoralf M.
    Schaff, Hartzell V.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 144 (01) : 108 - 111
  • [3] Diagnosis and Treatment of Early Bioprosthetic Malfunction in the Mitral Valve Position due to Thrombus Formation
    Butnaru, Adi
    Shaheen, Joseph
    Tzivoni, Dan
    Tauber, Rachel
    Bitran, Daniel
    Silberman, Shuli
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2013, 112 (09) : 1439 - 1444
  • [4] COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH
    DELONG, ER
    DELONG, DM
    CLARKEPEARSON, DI
    [J]. BIOMETRICS, 1988, 44 (03) : 837 - 845
  • [5] The porcine valve type predicts obstructive thrombosis beyond the first three postoperative months in bioprostheses in the aortic position
    Jander, Nikolaus
    Sommer, Harriet
    Pingpoh, Clarence
    Kienzle, Rolf-Peter
    Martin, Gabriele
    Zeh, Wolfgang
    Pache, Gregor
    Siepe, Matthias
    Beyersdorf, Friedhelm
    Schumacher, Martin
    Neumann, Franz-Josef
    Minners, Jan
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 199 : 90 - 95
  • [6] Usefulness of Phenprocoumon for the Treatment of Obstructing Thrombus in Bioprostheses in the Aortic Valve Position
    Jander, Nikolaus
    Kienzle, Rolf-Peter
    Kayser, Gian
    Neumann, Franz-Josef
    Gohlke-Baerwolf, Christa
    Minners, Jan
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2012, 109 (02) : 257 - 262
  • [7] Early Aortic Transcatheter Heart Valve Thrombosis Diagnostic Value of Contrast-Enhanced Multidetector Computed Tomography
    Leetmaa, Tina
    Hansson, Nicolaj C.
    Leipsic, Jonathon
    Jensen, Kaare
    Poulsen, Steen H.
    Andersen, Henning R.
    Jensen, Jesper M.
    Webb, John
    Blanke, Philipp
    Tang, Mariann
    Norgaard, Bjarne L.
    [J]. Circulation-Cardiovascular Interventions, 2015, 8 (04)
  • [8] Marchand M, 1998, J HEART VALVE DIS, V7, P292
  • [9] Association of Warfarin Therapy Duration After Bioprosthetic Aortic Valve Replacement With Risk of Mortality, Thromboembolic Complications, and Bleeding
    Merie, Charlotte
    Kober, Lars
    Olsen, Peter Skov
    Andersson, Charlotte
    Gislason, Gunnar
    Jensen, Jan Skov
    Torp-Pedersen, Christian
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2012, 308 (20): : 2118 - 2125
  • [10] Nishimura RA, 2014, J AM COLL CARDIOL, V63, P2438, DOI [10.1016/j.jacc.2014.02.537, 10.1016/j.jtcvs.2014.05.014, 10.1016/j.jacc.2014.02.536]