Bioprosthetic Valve Thrombosis Versus Structural Failure Clinical and Echocardiographic Predictors

被引:231
作者
Egbe, Alexander C. [1 ]
Pislaru, Sorin V. [1 ]
Pellikka, Patricia A. [1 ]
Poterucha, Joseph T. [1 ]
Schaff, Hartzell V. [2 ]
Maleszewski, Joseph J. [3 ]
Connolly, Heidi M. [1 ]
机构
[1] Mayo Clin, Div Cardiovasc Dis, Rochester, MN 55905 USA
[2] Mayo Clin, Div Cardiovasc Surg, Rochester, MN 55905 USA
[3] Mayo Clin, Anat Pathol, Rochester, MN 55905 USA
关键词
atrial fibrillation; cusp; Doppler gradient; valvular heart disease; vitamin K antagonist; REPLACEMENT; POSITION; RISK;
D O I
10.1016/j.jacc.2015.09.022
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Bioprosthetic valve thrombosis (BPVT) is considered uncommon; this may be related to the fact that it is often unrecognized. Recent data suggest that BPVT responds to vitamin K antagonists, emphasizing the need for reliable diagnosis. OBJECTIVES This study sought to determine the diagnostic features of BPVT and to formulate a diagnostic model for BPVT. METHODS Cases of BPVT occurring between 1997 and 2013 were identified from the Mayo Clinic pathology database. Patients with BPVT were matched 1: 2 for age, sex, and prosthesis position with patients whose valves were explanted for structural failure. We formulated a diagnostic model for BPVT using multivariate linear logistic regression and receiver operating characteristic. RESULTS Among 397 consecutive cases of explanted bioprostheses, there were 46 cases of BPVT (11.6%; aortic 29, mitral 9, tricuspid 7, pulmonary 1), mean age was 63 years, and 68% were male. Thirty (65%) cases occurred >12 months post-implantation; median bioprosthetic valve longevity was 24 months (cases) versus 108 months (controls) (p < 0.001). Independent predictors of BPVT were >50% increase in mean echo-Doppler gradient from baseline within 5 years (odds ratio [OR]: 12.7), paroxysmal atrial fibrillation (OR: 5.19), subtherapeutic international normalized ratio (OR: 7.37), increased cusp thickness (OR: 12.2), and abnormal cusp mobility (OR: 6.94). Presence of all 5 diagnostic features was predictive of BPVT with 76% sensitivity, 93% specificity, 85% positive predictive value, and 89% negative predictive value (p < 0.001). CONCLUSIONS BPVT is not uncommon and can occur several years after surgery. A combination of clinical and echocardiographic features can reliably diagnose BPVT. (C) 2015 by the American College of Cardiology Foundation.
引用
收藏
页码:2285 / 2294
页数:10
相关论文
共 18 条
[1]   Comprehensive Echocardiographic Assessment of the Hemodynamic Parameters of 285 Tricuspid Valve Bioprostheses Early after Implantation [J].
Blauwet, Lori A. ;
Danielson, Gordon K. ;
Burkhart, Harold M. ;
Dearani, Joseph A. ;
Malouf, Joseph F. ;
Connolly, Heidi M. ;
Hodge, David O. ;
Herges, Regina M. ;
Miller, Fletcher A., Jr. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (10) :1045-U72
[2]   Early thrombosis risk in patients with biologic valves in the aortic position [J].
Brown, Morgan L. ;
Park, Soon J. ;
Sundt, Thoralf M. ;
Schaff, Hartzell V. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 144 (01) :108-111
[3]   Diagnosis and Treatment of Early Bioprosthetic Malfunction in the Mitral Valve Position due to Thrombus Formation [J].
Butnaru, Adi ;
Shaheen, Joseph ;
Tzivoni, Dan ;
Tauber, Rachel ;
Bitran, Daniel ;
Silberman, Shuli .
AMERICAN JOURNAL OF CARDIOLOGY, 2013, 112 (09) :1439-1444
[4]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[5]   The porcine valve type predicts obstructive thrombosis beyond the first three postoperative months in bioprostheses in the aortic position [J].
Jander, Nikolaus ;
Sommer, Harriet ;
Pingpoh, Clarence ;
Kienzle, Rolf-Peter ;
Martin, Gabriele ;
Zeh, Wolfgang ;
Pache, Gregor ;
Siepe, Matthias ;
Beyersdorf, Friedhelm ;
Schumacher, Martin ;
Neumann, Franz-Josef ;
Minners, Jan .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 199 :90-95
[6]   Usefulness of Phenprocoumon for the Treatment of Obstructing Thrombus in Bioprostheses in the Aortic Valve Position [J].
Jander, Nikolaus ;
Kienzle, Rolf-Peter ;
Kayser, Gian ;
Neumann, Franz-Josef ;
Gohlke-Baerwolf, Christa ;
Minners, Jan .
AMERICAN JOURNAL OF CARDIOLOGY, 2012, 109 (02) :257-262
[7]   Early Aortic Transcatheter Heart Valve Thrombosis Diagnostic Value of Contrast-Enhanced Multidetector Computed Tomography [J].
Leetmaa, Tina ;
Hansson, Nicolaj C. ;
Leipsic, Jonathon ;
Jensen, Kaare ;
Poulsen, Steen H. ;
Andersen, Henning R. ;
Jensen, Jesper M. ;
Webb, John ;
Blanke, Philipp ;
Tang, Mariann ;
Norgaard, Bjarne L. .
Circulation-Cardiovascular Interventions, 2015, 8 (04)
[8]  
Marchand M, 1998, J HEART VALVE DIS, V7, P292
[9]   Association of Warfarin Therapy Duration After Bioprosthetic Aortic Valve Replacement With Risk of Mortality, Thromboembolic Complications, and Bleeding [J].
Merie, Charlotte ;
Kober, Lars ;
Olsen, Peter Skov ;
Andersson, Charlotte ;
Gislason, Gunnar ;
Jensen, Jan Skov ;
Torp-Pedersen, Christian .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2012, 308 (20) :2118-2125
[10]  
Nishimura RA, 2014, J AM COLL CARDIOL, V63, P2438, DOI [10.1016/j.jacc.2014.02.537, 10.1016/j.jtcvs.2014.05.014, 10.1016/j.jacc.2014.02.536]