A novel fibre Bragg grating pressure sensor for rotary ventricular assist devices

被引:12
作者
Stephens, Andrew F. [1 ,2 ,3 ,4 ]
Busch, Andrew [3 ]
Salamonsen, Robert F. [5 ,6 ]
Gregory, Shaun D. [1 ,2 ,3 ,4 ]
Tansley, Geoffrey D. [3 ,4 ]
机构
[1] Monash Univ, Dept Mech & Aerosp Engn, Clayton, Vic, Australia
[2] Baker Heart & Diabet Inst, Cardioresp Engn & Technol Lab, Melbourne, Vic, Australia
[3] Griffith Univ, Sch Engn & Built Environm, Nathan, Qld, Australia
[4] Prince Charles Hosp, Crit Care Res Grp, Innovat Cardiovasc Engn & Technol Lab, Chermside, Qld, Australia
[5] Alfred Hosp, Intens Care Unit, Melbourne, Vic, Australia
[6] Monash Univ, Dept Prevent Med & Epidemiol, Clayton, Vic, Australia
基金
英国医学研究理事会;
关键词
Implantable pressure sensor; Fibre Bragg grating; FBG; Ventricular assist device; VAD; Physiological control;
D O I
10.1016/j.sna.2019.06.028
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Ventricular assist devices are used to support patients with end-stage heart failure. Many patients on long-term VAD support are treated out-of-hospital where monitoring technology for patients is severely limited; leading to sub-optimal patient management. This paper describes a novel fibre Bragg grating (FBG) pressure sensor which was developed for improved monitoring of patients with ventricular assist devices. The FBG sensor was fabricated in-house and characterised in a circulating heat bath. The FBG pressure sensor demonstrated a sensitivity of -0.0046 nm/mmHg with an accuracy of +/- 0.35 mmHg, a resolution of 0.0019 mmHg and a response time of 89.7 mmHg/s. The high sensitivity and resolution combined with the adequate accuracy exhibited by the FBG sensor demonstrated its potential value of the FBG pressure sensor for monitoring patients with ventricular assist devices. Further investigation into device drift, improved manufacturing, and gas-impermeable biocompatible materials are required to prepare the sensor for pre-clinical trials. Crown Copyright (C) 2019 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:474 / 482
页数:9
相关论文
共 19 条
  • [1] ADAMSON PB, 2010, J CARD FAIL, V16, P913
  • [2] Bach H., 1998, SCHOTT SERIES GLASS
  • [3] An Implantable Intravascular Pressure Sensor for a Ventricular Assist Device
    Brancato, Luigi
    Keulemans, Grim
    Verbelen, Tom
    Meyns, Bart
    Puers, Robert
    [J]. MICROMACHINES, 2016, 7 (08):
  • [4] A blood pressure sensor for long-term implantation
    Bullister, E
    Reich, S
    d'Entremont, P
    Silverman, N
    Sluetz, J
    [J]. ARTIFICIAL ORGANS, 2001, 25 (05) : 376 - 379
  • [5] Chung N, 1992, J Am Soc Echocardiogr, V5, P147
  • [6] Development of an Inlet Pressure Sensor for Control in a Left Ventricular Assist Device
    Fritz, Bryan
    Cysyk, Joshua
    Newswanger, Ray
    Weiss, William
    Rosenberg, Gerson
    [J]. ASAIO JOURNAL, 2010, 56 (03) : 180 - 185
  • [7] Guglin M., 2016, VAD J, V2, P1
  • [8] Hall J., 2006, TXB MED PHYSL
  • [9] PHOTOSENSITIVITY IN OPTICAL FIBER WAVEGUIDES - APPLICATION TO REFLECTION FILTER FABRICATION
    HILL, KO
    FUJII, Y
    JOHNSON, DC
    KAWASAKI, BS
    [J]. APPLIED PHYSICS LETTERS, 1978, 32 (10) : 647 - 649
  • [10] Eighth annual INTERMACS report: Special focus on framing the impact of adverse events
    Kirklin, James K.
    Pagani, Francis D.
    Kormos, Robert L.
    Stevenson, Lynne W.
    Blume, Elizabeth D.
    Myers, Susan L.
    Miller, Marissa A.
    Baldwin, J. Timothy
    Young, James B.
    Naftel, David C.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (10) : 1080 - 1086