An evaluation of image noise variance for time-of-flight PET

被引:0
|
作者
Watson, Charles C. [1 ]
机构
[1] Siemens Med Solut Mol Imaging, Knoxville, TN 37932 USA
来源
2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5 | 2005年
关键词
POSITRON-EMISSION-TOMOGRAPHY; RECONSTRUCTION; SYSTEMS;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe a simple theoretical framework for linear time-of-flight (TOF) reconstruction and evaluate several alternative TOF filters. We implement a capability for direct computation of TOF noise variance images and evaluate the gain in image variance for TOF vs. non-TOF for 1.26 nsec TOF resolution on the Siemens biograph HiRez PET/CT. The variance calculation is validated by comparing to pixel variances computed from replicated synthetic data. TOF reconstruction does not give a uniform improvement in image noise variance, but improves variance more toward the periphery of an object than at its center. The TOF performance gain depends on how random coincidences are processed, and is greater when the randoms fraction is higher, or when randoms smoothing is not employed. We confirm that TOF gain is greater for larger objects than for smaller ones, but find discrepancies with the D/Delta x rule of thumb. With 1.26 nsec resolution on the HiRez, TOF image noise gain factors (non-TOF/TOF variance) range from 1.5 to 2.2 on the measured data at hand. We predict that an improvement in TOF resolution by a factor of 2 (to 600 psec) could improve image variance on this machine by an additional factor of 1.8. We find that confidence weighted TOF reconstruction under-performs non-TOF reconstruction for objects whose diameters are small compared to the TOF resolution.
引用
收藏
页码:2041 / 2045
页数:5
相关论文
共 50 条
  • [1] Fast Estimation of Image Variance for Time-of-flight PET Reconstruction
    Wang, Mengdie
    Hu, Guangshu
    El Fakhri, Georges
    Zhang, Hui
    Li, Quanzheng
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [2] Fisher Information-Based Evaluation of Image Quality for Time-of-Flight PET
    Vunckx, Kathleen
    Zhou, Lin
    Matej, Samuel
    Defrise, Michel
    Nuyts, Johan
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (02) : 311 - 321
  • [3] Improving time resolution in time-of-flight PET
    Conti, Maurizio
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S194 - S198
  • [4] Recent developments in time-of-flight PET
    Vandenberghe, S.
    Mikhaylova, E.
    D'Hoe, E.
    Mollet, P.
    Karp, J. S.
    EJNMMI PHYSICS, 2016, 3 (01):
  • [5] Update on Time-of-Flight PET Imaging
    Surti, Suleman
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (01) : 98 - 105
  • [6] Experimental evaluation of a simple lesion detection task with time-of-flight PET
    Surti, S.
    Karp, J. S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (02) : 373 - 384
  • [7] Time-of-flight PET image reconstruction using origin ensembles
    Wuelker, Christian
    Sitek, Arkadiusz
    Prevrhal, Sven
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (05) : 1919 - 1944
  • [8] Advances in time-of-flight PET
    Surti, Suleman
    Karp, Joel S.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (01): : 12 - 22
  • [9] Impact of Time-of-Flight on PET Tumor Detection
    Kadrmas, Dan J.
    Casey, Michael E.
    Conti, Maurizio
    Jakoby, Bjoern W.
    Lois, Cristina
    Townsend, David W.
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (08) : 1315 - 1323
  • [10] Focus on time-of-flight PET: the benefits of improved time resolution
    Conti, Maurizio
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (06) : 1147 - 1157