Comparison of Augmentation Methods for Internal Fixation of Osteoporotic Ankle Fractures

被引:32
作者
Panchbhavi, Vinod K. [1 ]
Vallurupalli, Santaram [1 ]
Morris, Randal [1 ]
机构
[1] Univ Texas Med Branch, Dept Orthopaed Surg & Rehabil, Galveston, TX 77555 USA
关键词
Internal Fixation; Osteoporotic Ankle Fractures; Ankle Fixation; MTS Machine; Lateral Fibular Plate; Supination External Rotation Injury; CALCIUM-PHOSPHATE CEMENT; BIOMECHANICAL EVALUATION; ELDERLY-PATIENTS; BONE; AGE;
D O I
10.3113/FAI.2009.0696
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Internal fixation of osteoporotic ankle fractures is associated with failure of fixation. This study compared different augmentation methods biomechanically. Materials and Methods: In nine paired fresh-frozen cadaver legs, an identical supination-external rotation type II ankle fracture was created. Fractures were stabilized using an eight-hole locking plate. In four pairs, two screws were inserted across the syndesmosis for purchase in the tibial metaphysis. One leg from each pair was randomly selected for injection of calcium sulphate-calcium phosphate graft into the screw holes. Each leg was mounted to an NITS machine in a custom loading frame. Axial cyclic loading to body weight was performed to measure displacement at the fracture site, followed by rotational loading to failure simulating a supination external rotation injury. Data were analyzed using a two-way paired t-test and ANOVA. Results: The specimens used had a mean bone mineral density of 0.49 +/- 0.15 (SD) g/cm(2), and a mean age of 83 +/- 12 years. In the biomechanical tests, there were no significant differences between augmented and non-augmented locking plates without the tibia-pro-fibula screws in axial stiffness (p = 0.10), external rotation angle at failure (p = 0.42), failure torque (p = 0.57), energy absorbed before failure (p = 0.47), and motion at the fracture site with cyclic axial loading (p = 0.15). There were no significant differences between augmented and non-augmented locking plates with the tibia-pro-fibula screws in the external rotation angle at failure (p = 0.83), failure torque (p = 0.58), and failure energy (p = 0.4). However, the overall strength of the fixation tended to increase with tibia-pro-fibula screws and augmentation. Conclusion: Internal fixation of an osteoporotic lateral malleolar fracture using a locking plate and screws provided a construct comparable in strength to that augmented with calcium sulfate-calcium phosphate graft and/or tibia-pro-fibula screws. Clinical Relevance: Strategies to augment internal fixation of osteoporotic ankle fractures may minimize risk for failure of fixation and may enable early weight bearing mobilization and return to function in elderly patients.
引用
收藏
页码:696 / 703
页数:8
相关论文
共 50 条
  • [21] An Overview of Internal and External Fixation Methods for the Diabetic Charcot Foot and Ankle
    Ramanujam, Crystal L.
    Zgonis, Thomas
    CLINICS IN PODIATRIC MEDICINE AND SURGERY, 2017, 34 (01) : 25 - +
  • [22] Fixation of Osteoporotic Fractures in the Upper Limb with a Locking Compression Plate
    Neuhaus, V
    King, J. D.
    Jupiter, J. B.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2012, 79 (05) : 404 - 410
  • [23] The role of intramedullary fixation in ankle fractures - A systematic review
    Jordan, R. W.
    Chapman, A. W. P.
    Buchanan, D.
    Makrides, P.
    FOOT AND ANKLE SURGERY, 2018, 24 (01) : 1 - 10
  • [24] A BIOMECHANICAL COMPARISON OF 2 METHODS OF FIXATION OF FRACTURES OF THE FOREARM
    JONES, DJ
    HENLEY, MB
    SCHEMITSCH, EH
    TENCER, AF
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1995, 9 (03) : 198 - 206
  • [25] Surgical Fixation of Quadrimalleolar Fractures of the Ankle
    Rammelt, Stefan
    Bartonicek, Jan
    Kroker, Livia
    Neumann, Annika Pauline
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2021, 35 (06) : E216 - E222
  • [26] Internal fixation of experimental intraarticular calcaneal fractures: A biomechanical analysis of two fixation methods
    Carr, JB
    Tigges, RG
    Wayne, JS
    Earll, M
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (06) : 425 - 428
  • [27] Outcomes Following Open Reduction Internal Fixation of Ankle Fractures (ORIF) By Podiatric Surgeons
    Weinraub, Glenn M.
    Newport, Ian
    Kim, Brandon K.
    Zhu, Shiyun
    Patel, Sumer
    JOURNAL OF FOOT & ANKLE SURGERY, 2021, 60 (05) : 960 - 963
  • [28] Simultaneous open reduction and internal fixation and total hip arthroplasty for the treatment of osteoporotic acetabular fractures
    Salama, Wael
    Mousa, Shazly
    Khalefa, Abdelrahman
    Sleem, Ahmed
    Kenawey, Mohamed
    Ravera, Laura
    Masse, Alessandro
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (01) : 181 - 189
  • [29] Vertebral Augmentation plus Pedicle Screw Fixation versus Vertebral Augmentation Alone in the Treatment of Osteoporotic Thoracolumbar Fractures: A Meta-Analysis
    Yan, Wenshan
    Song, Haiyu
    Cao, Weili
    Ma, Dengyue
    Sun, Ming
    WORLD NEUROSURGERY, 2025, 195
  • [30] Comparison of modern locked plating and antiglide plating for fixation of osteoporotic distal fibular fractures
    Switaj, Paul J.
    Wetzel, Robert J.
    Jain, Neel P.
    Weatherford, Brian M.
    Ren, Yupeng
    Zhang, Li-Qun
    Merk, Bradley R.
    FOOT AND ANKLE SURGERY, 2016, 22 (03) : 158 - 163