Comparison of Augmentation Methods for Internal Fixation of Osteoporotic Ankle Fractures

被引:32
|
作者
Panchbhavi, Vinod K. [1 ]
Vallurupalli, Santaram [1 ]
Morris, Randal [1 ]
机构
[1] Univ Texas Med Branch, Dept Orthopaed Surg & Rehabil, Galveston, TX 77555 USA
关键词
Internal Fixation; Osteoporotic Ankle Fractures; Ankle Fixation; MTS Machine; Lateral Fibular Plate; Supination External Rotation Injury; CALCIUM-PHOSPHATE CEMENT; BIOMECHANICAL EVALUATION; ELDERLY-PATIENTS; BONE; AGE;
D O I
10.3113/FAI.2009.0696
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Internal fixation of osteoporotic ankle fractures is associated with failure of fixation. This study compared different augmentation methods biomechanically. Materials and Methods: In nine paired fresh-frozen cadaver legs, an identical supination-external rotation type II ankle fracture was created. Fractures were stabilized using an eight-hole locking plate. In four pairs, two screws were inserted across the syndesmosis for purchase in the tibial metaphysis. One leg from each pair was randomly selected for injection of calcium sulphate-calcium phosphate graft into the screw holes. Each leg was mounted to an NITS machine in a custom loading frame. Axial cyclic loading to body weight was performed to measure displacement at the fracture site, followed by rotational loading to failure simulating a supination external rotation injury. Data were analyzed using a two-way paired t-test and ANOVA. Results: The specimens used had a mean bone mineral density of 0.49 +/- 0.15 (SD) g/cm(2), and a mean age of 83 +/- 12 years. In the biomechanical tests, there were no significant differences between augmented and non-augmented locking plates without the tibia-pro-fibula screws in axial stiffness (p = 0.10), external rotation angle at failure (p = 0.42), failure torque (p = 0.57), energy absorbed before failure (p = 0.47), and motion at the fracture site with cyclic axial loading (p = 0.15). There were no significant differences between augmented and non-augmented locking plates with the tibia-pro-fibula screws in the external rotation angle at failure (p = 0.83), failure torque (p = 0.58), and failure energy (p = 0.4). However, the overall strength of the fixation tended to increase with tibia-pro-fibula screws and augmentation. Conclusion: Internal fixation of an osteoporotic lateral malleolar fracture using a locking plate and screws provided a construct comparable in strength to that augmented with calcium sulfate-calcium phosphate graft and/or tibia-pro-fibula screws. Clinical Relevance: Strategies to augment internal fixation of osteoporotic ankle fractures may minimize risk for failure of fixation and may enable early weight bearing mobilization and return to function in elderly patients.
引用
收藏
页码:696 / 703
页数:8
相关论文
共 50 条
  • [1] Internal Fixation of Osteoporotic Fractures
    Rothberg, David L.
    Lee, Mark A.
    CURRENT OSTEOPOROSIS REPORTS, 2015, 13 (01): : 16 - 21
  • [2] Internal Fixation of Osteoporotic Fractures
    David L. Rothberg
    Mark A. Lee
    Current Osteoporosis Reports, 2015, 13 : 16 - 21
  • [3] Osteoporotic Ankle Fractures
    Olsen, Joshua R.
    Hunter, Joshua
    Baumhauer, Judith F.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2013, 44 (02) : 225 - 241
  • [4] Osteoporotic Ankle Fractures: An Approach to Operative Management
    McKean, Jason
    Cuellar, Derly O.
    Hak, David
    Mauffrey, Cyril
    ORTHOPEDICS, 2013, 36 (12) : 936 - 940
  • [5] Outcomes of locking plate fixation with fibular allograft augmentation for proximal humeral fractures in osteoporotic patients COMPARISON WITH LOCKING PLATE FIXATION ALONE
    Lee, S. H.
    Han, S. S.
    Yoo, B. M.
    Kim, J. W.
    BONE & JOINT JOURNAL, 2019, 101B (03) : 260 - 265
  • [6] Three internal fixation methods for Danis-Weber-B distal fibular fractures: A biomechanical comparison in an osteoporotic fibula model
    Hollensteiner, Marianne
    Sandriesser, Sabrina
    Krauss, Hilmar
    Greinwald, Markus
    Stuby, Fabian
    Augat, Peter
    FOOT AND ANKLE SURGERY, 2022, 28 (07) : 845 - 851
  • [7] The use of augmentation techniques in osteoporotic fracture fixation
    Kammerlander, Christian
    Neuerburg, Carl
    Verlaan, Jorrit-Jan
    Schmoelz, Werner
    Miclau, Theodore
    Larsson, Sune
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 : S36 - S43
  • [8] Optimising implant anchorage (augmentation) during fixation of osteoporotic fractures: Is there a role for bone-graft substitutes?
    Larsson, Sune
    Procter, Philip
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 : S72 - S76
  • [9] Treatment of unstable distal clavicle fractures (Neer type II): A comparison of three internal fixation methods
    Xiong, Jian
    Chen, Jian-Hai
    Dang, Yu
    Zhang, Dian-Ying
    Fu, Zhong-Guo
    Zhang, Pei-Xun
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2018, 46 (11) : 4678 - 4683
  • [10] Osteoporotic Hip Fractures: The Burden of Fixation Failure
    Broderick, J. M.
    Bruce-Brand, R.
    Stanley, E.
    Mulhall, K. J.
    SCIENTIFIC WORLD JOURNAL, 2013,