Multicenter study on the diagnostic value of a new RIA for the detection of free plasma metanephrines in the work-up for pheochromocytoma

被引:12
作者
Lenz, Tomas
Zorner, Joachim
Kirchmaier, Carl
Pillitteri, Daniele
Badenhoop, Klaus
Bartel, Christine
Geiger, Helmut
Hasselbacher, Katrin
Tuschy, Ulrich
Westermann, Juergen
Salewski, Lothar
机构
[1] KfH Nierenzentrum, Inst Prevent Kidney Dis & Hypertens, D-67059 Ludwigshafen, Germany
[2] Deutsch Klin Diagnost, Dept Hemostasiol, D-65191 Wiesbaden, Germany
[3] Univ Hosp, Med Clin 1, D-60590 Frankfurt, Germany
[4] Univ Hosp, Med Clin 2, D-60590 Frankfurt, Germany
[5] HELIOS Klin, Med Clin 2, D-99089 Erfurt, Germany
[6] IBL GmbH, D-22335 Hamburg, Germany
[7] Inst Prevent Kidney Dis & Hypertens, D-67059 Ludwigshafen, Germany
来源
PHEOCHROMOCYTOMA | 2006年 / 1073卷
关键词
pheochromocytoma; immunoassay; free plasma metanephrines; LC-MS/MS; heparin; EDTA;
D O I
10.1196/annals.1353.040
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Available laboratory test methods for the detection of elevated concentrations of catecholamines and their metabolites in urine and/or plasma are not always sensitive enough for the detection of pheochromocytoma. High-quality immunoassays for these compounds appear to be as accurate as high-pressure liquid chromatography (HPLC) or gas chromatography/mass spectrometry (GC-MS). Therefore, the current project aims to establish a new sensitive radioimmunoassay (RIA) for the measurement of free metanephrines in the plasma of patients in the work-up for pheochromocytoma. We report first results of an ongoing multicenter clinico-chemical evaluation study in hypertensive patients and normotensive volunteers. After an overnight fast plasma samples were collected on ice in EDTA- and heparin-coated tubes after insertion of an indwelling venous line and resting in the supine (patients) or sitting position (normal volunteers) for 30 min. Plasma metanephrines were measured by a newly developed RIA from IBL, Hamburg, Germany. Good agreement of the assay with the tandem mass spectrometry (LCMS/MS) method for normetanephrine (r(2)=0.975) and for metanephrine (r(2)=0.985) could be demonstrated. Both specimens, EDTA and heparin plasma, can be used with the same results. The RIA has a good precision of < 15% in the normal range and of < 10% in the elevated concentration range. Our preliminary data suggest a high validity of the newly developed RIA for measuring free metanephrine and normetanephrine in hypertensive subjects in both EDTA and heparin plasma. Further work is required to determine the accuracy of the test in larger patient populations and in patients with pheochromocytoma.
引用
收藏
页码:358 / 373
页数:16
相关论文
共 18 条
[1]   Investigation of phaeochromocytoma [J].
Bouloux, PMG ;
Fakeeh, M .
CLINICAL ENDOCRINOLOGY, 1995, 43 (06) :657-664
[2]  
GERLO EAM, 1994, CLIN CHEM, V40, P250
[3]   LABORATORY DIAGNOSIS OF PHEOCHROMOCYTOMA - WHICH ANALYTES SHOULD WE MEASURE [J].
GRAHAM, PE ;
SMYTHE, GA ;
EDWARDS, GA ;
LAZARUS, L .
ANNALS OF CLINICAL BIOCHEMISTRY, 1993, 30 :129-134
[4]  
Grouzmann E, 2001, CLIN CHEM, V47, P1075
[5]   Phaeochromocytoma [J].
Lenders, JWM ;
Eisenhofer, G ;
Mannelli, M ;
Pacak, K .
LANCET, 2005, 366 (9486) :665-675
[6]   Adrenal pheochromocytoma remains a frequently overlooked diagnosis [J].
Lo, CY ;
Lam, KY ;
Wat, MS ;
Lam, KS .
AMERICAN JOURNAL OF SURGERY, 2000, 179 (03) :212-215
[7]   Pheochromocytoma: Study of 50 cases [J].
Lucon, AM ;
Pereira, MAA ;
Mendonca, BB ;
Halpern, A ;
Wajchenbeg, BL ;
Arap, S .
JOURNAL OF UROLOGY, 1997, 157 (04) :1208-1212
[8]   Pheochromocytoma in Italy: a multicentric retrospective study [J].
Mannelli, M ;
Ianni, L ;
Cilotti, A ;
Conti, A .
EUROPEAN JOURNAL OF ENDOCRINOLOGY, 1999, 141 (06) :619-624
[9]  
PASSING H, 1983, J CLIN CHEM CLIN BIO, V21, P709
[10]  
PLATTS JK, 1995, J ROY COLL PHYS LOND, V29, P299