Optical coherence tomography study of healing characteristics of paclitaxel-eluting balloons vs. everolimus-eluting stents for in-stent restenosis: the SEDUCE (Safety and Efficacy of a Drug elUting balloon in Coronary artery rEstenosis) randomised clinical trial

被引:62
|
作者
Adriaenssens, Tom [1 ,2 ]
Dens, Jo [3 ]
Ughi, Giovanni [1 ,2 ]
Bennett, Johan [1 ,2 ]
Dubois, Christophe [1 ,2 ]
Sinnaeve, Peter [1 ,2 ]
Wiyono, Stefanus [1 ,2 ]
Coosemans, Mark [1 ,2 ]
Belmans, Ann [1 ,2 ]
D'hooge, Jan [1 ,2 ]
Vrolix, Mathias [3 ]
Desmet, Walter [1 ,2 ]
机构
[1] Katholieke Univ Leuven, Dept Cardiovasc Dis, Univ Hosp Leuven, Leuven, Belgium
[2] Katholieke Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium
[3] ZOL Hosp Genk, Genk, Belgium
关键词
drug-eluting balloon; drug-eluting stent; in-stent restenosis; optical coherence tomography; percutaneous coronary intervention; stent coverage; BARE-METAL STENTS; COATED BALLOON; FOLLOW-UP; VASCULAR BRACHYTHERAPY; MYOCARDIAL-INFARCTION; NEOINTIMAL COVERAGE; ANGIOPLASTY; NEOATHEROSCLEROSIS; ANGIOGRAPHY; PREVENTION;
D O I
10.4244/EIJV10I4A77
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: Little is known about the respective healing responses and clinical efficacy and safety of drug-eluting balloons (DEB) and the second generation of drug-eluting stents (DES) when used to treat in-stent restenosis (ISR). In this study, we set out to compare prospectively the healing characteristics, as assessed by optical coherence tomography (OCT), of DEB versus DES after treatment of ISR in bare metal stents (BMS). Methods and results: Fifty patients with BMS ISR were randomised to treatment with a paclitaxel-eluting balloon vs. an everolimus-eluting stent (EES). The primary endpoint was the percentage of uncovered struts, assessed with OCT at nine months, as a marker of vessel wall healing. A mean of 366 +/- 135 and 636 +/- 184 struts were analysed per patient in the DEB and EES groups, respectively. The percentage of uncovered struts per patient was significantly lower with DEB vs. EES (1.4% vs. 3.1%, p=0.025). Mean neointimal hyperplasia area was 2.4 +/- 1.08 mm(2) in DEB vs. 1.92 +/- 0.67 mm(2) in EES (p=0.1806), while the percentage of malapposed struts per patient was very low in both groups (0.2% vs. 0.3%, p=0.699). At nine months, angiographic in-stent MLD (minimum lumen diameter) was lower (2.13 vs. 2.54 mm, p=0.006), while diameter stenosis (26.4 vs. 11.4%, p=0.002), and LLL (0.28 vs. 0.07 mm, p=0.1) were higher after DEB compared to EES. During one-year follow-up, we did not observe differences in the rates of death, TLR (target lesion revascularisation) or stent thrombosis. Conclusions: DEB appears to be associated with better healing characteristics, as assessed by stent strut coverage with OCT, but tended to be slightly less effective compared to EES. These findings give support to the use of either DEB or EES as valuable treatment options for ISR.
引用
收藏
页码:439 / 448
页数:10
相关论文
共 50 条
  • [41] A prospective randomised study using optical coherence tomography to assess endothelial coverage and neointimal proliferation at 6-months after implantation of a coronary everolimus-eluting stent compared with a bare metal stent postdilated with a paclitaxel-eluting balloon (OCTOPUS trial): rationale, design and methods
    Poerner, Tudor C.
    Otto, Sylvia
    Gassdorf, Johannes
    Janiak, Florian
    Danzer, Constance
    Ferrari, Markus
    Figulla, Hans R.
    EUROINTERVENTION, 2011, 7 : K93 - K99
  • [42] Clinical Efficacy of Treatment of Coronary in-Stent Restenosis with Drug Eluting Balloon Catheter - New Standard of Care?
    Xia, Hong Yuan
    Low, Adrian Fatt Heo
    Lee, Chi-Hang
    Teo, Swee Guan
    Chan, Mark
    Chan, Koo Hui
    Tan, Huay Cheem
    CIRCULATION, 2010, 122 (21)
  • [43] In-stent restenosis assessed with frequency domain optical coherence tomography shows smooth coronary arterial healing process in second-generation drug-eluting stents
    Kajiya, Takashi
    Yamaguchi, Hiroshi
    Takaoka, Junichiro
    Fukunaga, Kengo
    Arima, Ryoichi
    Miyamura, Akihiro
    Ninomiya, Toshiko
    Atsuchi, Nobuhiko
    Atsuchi, Yoshihiko
    Terashima, Mitsuyasu
    Kaneda, Hideaki
    Ohishi, Mitsuru
    SINGAPORE MEDICAL JOURNAL, 2019, 60 (01) : 48 - 51
  • [44] Ten-year clinical outcomes of first-generation drug-eluting stents: the Sirolimus-Eluting vs. Paclitaxel-Eluting Stents for Coronary Revascularization (SIRTAX) VERY LATE trial
    Yamaji, Kyohei
    Raber, Lorenz
    Zanchin, Thomas
    Spitzer, Ernest
    Zanchin, Christian
    Pilgrim, Thomas
    Stortecky, Stefan
    Moschovitis, Aris
    Billinger, Michael
    Schonenberger, Christa
    Eberli, Franz
    Juni, Peter
    Luscher, Thomas F.
    Heg, Dik
    Windecker, Stephan
    EUROPEAN HEART JOURNAL, 2016, 37 (45) : 3386 - 3395
  • [45] ISAR-PEBIS (Paclitaxel-Eluting Balloon Versus Conventional Balloon Angioplasty for In-Stent Restenosis of Superficial Femoral Artery): A Randomized Trial
    Ott, Ilka
    Cassese, Salvatore
    Groha, Philipp
    Steppich, Birgit
    Voll, Felix
    Hadamitzky, Martin
    Ibrahim, Tareq
    Kufner, Sebastian
    Dewitz, Karl
    Wittmann, Theresa
    Kasel, Albert Markus
    Laugwitz, Karl-Ludwig
    Schunkert, Heribert
    Kastrati, Adnan
    Fusaro, Massimiliano
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2017, 6 (07):
  • [46] Stent Coverage and Neointimal Proliferation in Bare Metal Stents Postdilated With a Paclitaxel-Eluting Balloon Versus Everolimus-Eluting Stents Prospective Randomized Study Using Optical Coherence Tomography at 6-Month Follow-Up
    Poerner, Tudor C.
    Otto, Sylvia
    Gassdorf, Johannes
    Nitsche, Kristina
    Janiak, Florian
    Scheller, Bruno
    Goebel, Bjoern
    Jung, Christian
    Figulla, Hans R.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (06) : 760 - U53
  • [47] Comparison of in-stent neoatherosclerosis and tissue characteristics between early and late in-stent restenosis in second-generation drug-eluting stents: an optical coherence tomography study
    Mahmoud Sabbah
    Kazushige Kadota
    Azza El-Eraky
    Hanan M. Kamal
    Ahmed-Tageldien Abdellah
    Ahmed El Hawary
    The International Journal of Cardiovascular Imaging, 2017, 33 : 1463 - 1472
  • [48] Long-Term Results of Everolimus-Eluting Stents Versus Drug-Eluting Balloons in Patients With Bare-Metal In-Stent Restenosis 3-Year Follow-Up of the RIBS V Clinical Trial
    Alfonso, Fernando
    Jose Perez-Vizcayno, Maria
    Garcia del Blanco, Bruno
    Otaegui, Imanol
    Masotti, Monica
    Zueco, Javier
    Velaquez, Maite
    Sanchis, Juan
    Garcia-Touchard, Arturo
    Lazaro-Garcia, Rosa
    Moreu, Jose
    Bethencourt, Armando
    Cuesta, Javier
    Rivero, Fernando
    Cardenas, Alberto
    Gonzalo, Nieves
    Jimenez-Quevedo, Pilar
    Fernandez, Cristina
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (12) : 1246 - 1255
  • [49] A meta-analysis of randomised controlled trials assessing drug-eluting stents and vascular brachytherapy in the treatment of coronary artery in-stent restenosis
    Oliver, Lisa N.
    Buttner, Petra G.
    Hobson, Helen
    Golledge, Jonathan
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 126 (02) : 216 - 223
  • [50] Paclitaxel-Eluting Balloon vs. Standard Angioplasty to Reduce Recurrent Restenosis in Diabetic Patients With In-Stent Restenosis of the Superficial Femoral and Proximal Popliteal Arteries: The DEBATE-ISR Study
    Liistro, Francesco
    Angioli, Paolo
    Porto, Italo
    Ricci, Lucia
    Ducci, Kenneth
    Grotti, Simone
    Falsini, Giovanni
    Ventoruzzo, Giorgio
    Turini, Filippo
    Bellandi, Guido
    Bolognese, Leonardo
    JOURNAL OF ENDOVASCULAR THERAPY, 2014, 21 (01) : 1 - 8